The DOI matches its Crossref record.
Noninvasive Imaging of Myocardial Reperfusion Injury Using Leukocyte-Targeted Contrast Echocardiography
Open accessAbstract
Background — We hypothesized that myocardial contrast echocardiography (MCE) with leukocyte-targeted microbubbles could temporally and spatially characterize the severity of postischemic myocardial inflammation. Methods and Results — In 9 open-chest dogs, either the left anterior descending or left circumflex coronary artery was occluded for 90 minutes (n=6), while the remaining dogs served as non-ischemic controls. During occlusion, MCE was performed to determine the risk area (RA) and regions supplied by collateral flow. Myocardial inflammation was assessed 5, 60, and 120 minutes after reflow by MCE imaging of leukocyte-targeted (phosphatidylserine-containing) lipid microbubbles. The spatial extent and severity of inflammation were also assessed by radionuclide imaging of the neutrophil-avid tracer 99m TcRP517 and tissue myeloperoxidase activity. Early after reflow, MCE detected inflammation throughout the entire risk area, the extent of which decreased over time due to reduced signal in collateral-supplied regions. The spatial extent of inflammation late after reflow was similar for MCE and radionuclide imaging. The severity of inflammation in the infarct zone, the noninfarcted risk area, and collateral-supplied territories determined by quantitative MCE correlated well with myeloperoxidase activity ( r =0.81). Conclusions — MCE with leukocyte-targeted microbubbles can temporally assess the severity and extent of postischemic myocardial inflammation and could be used to evaluate new treatment strategies designed to limit inflammation in acute coronary syndromes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Self-citationKlibanov, A. L. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199292.88189.0f · Cited by 424
Self-citationMicrobubbles and ultrasound: from diagnosis to therapy
DIJKMANS, P., JUFFERMANS, L., MUSTERS, R., VANWAMEL, A., TENCATE, F., VANGILST, W., VISSER, C., DEJONG, N., & KAMP, O. (2004) · European Journal of Echocardiography · doi:10.1016/j.euje.2004.02.001 · Cited by 420
Noninvasive Assessment of Angiogenesis by Ultrasound and Microbubbles Targeted to α v -Integrins
Leong-Poi, H., Christiansen, J., Klibanov, A. L., Kaul, S., & Lindner, J. R. (2003) · Circulation · doi:10.1161/01.cir.0000044916.05919.8b · Cited by 334
Self-citationDrug loaded microbubble design for ultrasound triggered delivery
Lentacker, I., De Smedt, S. C., & Sanders, N. N. (2009) · Soft Matter · doi:10.1039/b823051j · Cited by 264
Metadata
- Authors
- Christiansen, J. P., Leong-Poi, H., Klibanov, A. L., Kaul, S., & Lindner, J. R.
- Venue
- Circulation
- Published
- 2002-04-16
- Volume
- 105
- Issue
- 15
- Pages
- 1764-1767
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1967271515
- Cited by
- 161
- References
- 0
- FWCI
- 8.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Imaging of Myocardial Reperfusion Injury Using Leukocyte-Targeted Contrast Echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.0000015466.89771.e2
- The paper
- Christiansen, J. P., Leong-Poi, H., Klibanov, A. L., Kaul, S., & Lindner, J. R. (2002). Noninvasive Imaging of Myocardial Reperfusion Injury Using Leukocyte-Targeted Contrast Echocardiography. Circulation. https://doi.org/10.1161/01.cir.0000015466.89771.e2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.