The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Noninvasive Assessment of Angiogenesis by Ultrasound and Microbubbles Targeted to α v -Integrins
Open accessAbstract
Background— Noninvasive methods for characterizing neovessel formation during angiogenesis are currently lacking. We hypothesized that angiogenesis could be imaged with the use of contrast-enhanced ultrasound (CEU) with microbubbles targeted to α v -integrins. Methods and Results— Microbubbles targeted to α v -integrins were prepared by conjugating echistatin (MB E ) or monoclonal antibody against murine α v (MB α ) to their surface. Control microbubbles (MB c ) were also prepared. The microvascular behavior of these microbubbles was assessed by intravital microscopy of the cremaster muscle in mice treated for 4 days with sustained-release FGF-2. Microvascular retention was much greater ( P <0.01) for MB E (11±6 mm −3 ) and MB α (10±7 mm −3 ) than that for MB c (1±1 mm −3 ). Retained MB E and MB α attached directly to the microvascular endothelial surface. Microbubble retention in 4 control mice was minimal. Subcutaneous matrigel plugs enriched with FGF-2 were created in 12 mice and studied 10 days later. Neovessels within the matrigel stained positive for α v -integrins. CEU demonstrated greater ( P <0.01) acoustic intensity for MB E (16.0±5.9 U) and MB α (17.0±5.5 U) compared with MB c (5.8±2.6 U). The signal from targeted microbubbles (MB E and MB α ) correlated well ( r =0.90) with the matrigel blood volume determined by CEU perfusion imaging. Conclusions— CEU with microbubbles targeted for α v -integrins may provide a noninvasive method for assessing therapeutic angiogenesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Requirement of Vascular Integrin α v β 3 for Angiogenesis
Brooks, P. C., Clark, R. A. F., & Cheresh, D. A. (1994) · Science · doi:10.1126/science.7512751 · Cited by 3,020
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Self-citationDefinition of Two Angiogenic Pathways by Distinct α v Integrins
Friedlander, M., Brooks, P. C., Shaffer, R. W., Kincaid, C. M., Varner, J. A., & Cheresh, D. A. (1995) · Science · doi:10.1126/science.270.5241.1500 · Cited by 1,321
Detection of tumor angiogenesis in vivo by αvβ3-targeted magnetic resonance imaging
Sipkins, D. A., Cheresh, D. A., Kazemi, M. R., Nevin, L. M., Bednarski, M. D., & Li, K. C. P. (1998) · Nature Medicine · doi:10.1038/nm0598-623 · Cited by 850
Passaniti, A., Taylor, R. M., Пили, Р., Guo, Y., Long, P., Haney, J. A., Pauly, R. R., Grant, D. S., & Martin, G. R. (1992) · PubMed · Cited by 806
Eliceiri, B. P., & Cheresh, D. A. (1999) · Journal of Clinical Investigation · doi:10.1172/jci6869 · Cited by 649
Haubner, R., Wester, H. J., Weber, W., Mang, C., Ziegler, S. I., Goodman, S. L., Senekowitsch–Schmidtke, R., Kessler, H., & Schwaiger, M. (2001) · PubMed · Cited by 563
Involvement of integrins alpha v beta 3 and alpha v beta 5 in ocular neovascular diseases.
Friedlander, M., Theesfeld, C. L., Sugita, M., Fruttiger, M., Thomas, M. A., Chang, S., & Cheresh, D. A. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.18.9764 · Cited by 452
Echocardiographic Destruction of Albumin Microbubbles Directs Gene Delivery to the Myocardium
Shohet, R. V., Chen, S., Zhou, Y.-T., Wang, Z., Meidell, R. S., Unger, R. H., & Grayburn, P. A. (2000) · Circulation · doi:10.1161/01.cir.101.22.2554 · Cited by 446
Lindner, J. R., Song, J., Christiansen, J., Klibanov, A. L., Xu, F., & Ley, K. (2001) · Circulation · doi:10.1161/hc4201.097061 · Cited by 441
Self-citation
Cited by
Integrins in angiogenesis and lymphangiogenesis
Avraamides, C. J., Garmy-Susini, B., & Varner, J. A. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2353 · Cited by 1,050
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Self-citationMicrobubbles and ultrasound: from diagnosis to therapy
DIJKMANS, P., JUFFERMANS, L., MUSTERS, R., VANWAMEL, A., TENCATE, F., VANGILST, W., VISSER, C., DEJONG, N., & KAMP, O. (2004) · European Journal of Echocardiography · doi:10.1016/j.euje.2004.02.001 · Cited by 420
Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery
Paefgen, V., Doleschel, D., & Kiessling, F. (2015) · Frontiers in Pharmacology · doi:10.3389/fphar.2015.00197 · Cited by 272
Engineered nanoparticles for biomolecular imaging
Mahmoudi, M., Serpooshan, V., & Laurent, S. (2011) · Nanoscale · doi:10.1039/c1nr10326a · Cited by 262
Metadata
- Authors
- Leong-Poi, H., Christiansen, J., Klibanov, A. L., Kaul, S., & Lindner, J. R.
- Venue
- Circulation
- Published
- 2003-01-28
- Volume
- 107
- Issue
- 3
- Pages
- 455-460
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2062437832
- Cited by
- 334
- References
- 23
- FWCI
- 22.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Assessment of Angiogenesis by Ultrasound and Microbubbles Targeted to α v -Integrins. https://app.cochat.ai/papers/10.1161/01.cir.0000044916.05919.8b
- The paper
- Leong-Poi, H., Christiansen, J., Klibanov, A. L., Kaul, S., & Lindner, J. R. (2003). Noninvasive Assessment of Angiogenesis by Ultrasound and Microbubbles Targeted to α v -Integrins. Circulation. https://doi.org/10.1161/01.cir.0000044916.05919.8b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.