Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 324

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Coronary Pressure Measurement After Stenting Predicts Adverse Events at Follow-Up: A Multicenter Registry

Pijls, Nico H.J., Klauss, Volker, Siebert, Uwe, Powers, Eric, Takazawa, Kenji, Fearon, William F., Escaned, Javier, Tsurumi, Yukio, Akasaka, Takashi, Samady, Habib, De Bruyne, Bernard·2002·Circulation

Abstract

Background — Coronary stenting is associated with a restenosis rate of 15% to 20% at 6-month follow-up, despite optimum angiographic stent implantation. In this multicenter registry, we investigated the relation between optimum physiological stent implantation as assessed by poststent fractional flow reserve (FFR) and outcome at 6 months. Methods and Results — In 750 patients, coronary pressure measurement at maximum hyperemia was performed after angiographically apparently satisfactory stent implantation. Poststenting FFR was calculated and related to major adverse events (including need for repeat target vessel revascularization) at 6 months. In 76 patients (10.2%), at least 1 adverse event occurred. Five patients died, 19 experienced myocardial infarction, and 52 underwent at least 1 repeat target vessel revascularization. By multivariate analysis, FFR immediately after stenting was the most significant independent variable related to all types of events. In 36% of the patients, FFR normalized (>0.95), and event rate was 4.9% in that group. In 32% of the patients, poststent FFR was between 0.90 and 0.95, and event rate was 6.2%. In 32% of patients, poststent FFR was <0.90, and event rate was 20.3%. In 6% of the patients, FFR was <0.80, and event rate was 29.5% ( P <0.001). Conclusions — FFR after stenting is a strong independent predictor of outcome at 6 months.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000020547.92091.76

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 324

Metadata

Authors
Pijls, N. H. J., Klauss, V., Siebert, U., Powers, E., Takazawa, K., Fearon, W. F., Escaned, J., Tsurumi, Y., Akasaka, T., Samady, H., & De Bruyne, B.
Venue
Circulation
Published
2002-06-25
Volume
105
Issue
25
Pages
2950-2954
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2129548351
Cited by
324
References
6
FWCI
14.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Coronary Pressure Measurement After Stenting Predicts Adverse Events at Follow-Up: A Multicenter Registry. https://app.cochat.ai/papers/10.1161/01.cir.0000020547.92091.76
The paper
Pijls, N. H. J., Klauss, V., Siebert, U., Powers, E., Takazawa, K., Fearon, W. F., Escaned, J., Tsurumi, Y., Akasaka, T., Samady, H., & De Bruyne, B. (2002). Coronary Pressure Measurement After Stenting Predicts Adverse Events at Follow-Up: A Multicenter Registry. Circulation. https://doi.org/10.1161/01.cir.0000020547.92091.76

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.