The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Coronary Pressure Measurement After Stenting Predicts Adverse Events at Follow-Up: A Multicenter Registry
Abstract
Background — Coronary stenting is associated with a restenosis rate of 15% to 20% at 6-month follow-up, despite optimum angiographic stent implantation. In this multicenter registry, we investigated the relation between optimum physiological stent implantation as assessed by poststent fractional flow reserve (FFR) and outcome at 6 months. Methods and Results — In 750 patients, coronary pressure measurement at maximum hyperemia was performed after angiographically apparently satisfactory stent implantation. Poststenting FFR was calculated and related to major adverse events (including need for repeat target vessel revascularization) at 6 months. In 76 patients (10.2%), at least 1 adverse event occurred. Five patients died, 19 experienced myocardial infarction, and 52 underwent at least 1 repeat target vessel revascularization. By multivariate analysis, FFR immediately after stenting was the most significant independent variable related to all types of events. In 36% of the patients, FFR normalized (>0.95), and event rate was 4.9% in that group. In 32% of the patients, poststent FFR was between 0.90 and 0.95, and event rate was 6.2%. In 32% of patients, poststent FFR was <0.90, and event rate was 20.3%. In 6% of the patients, FFR was <0.80, and event rate was 29.5% ( P <0.001). Conclusions — FFR after stenting is a strong independent predictor of outcome at 6 months.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery Stenoses
Pijls, N. H. J., de Bruyne, B., Peels, K., van der Voort, P. H., Bonnier, H. J. R. M., Bartunek, J., & Koolen, J. J. (1996) · New England Journal of Medicine · doi:10.1056/nejm199606273342604 · Cited by 2,321
Self-citationModeling and variable selection in epidemiologic analysis
Greenland, S. (1989) · American Journal of Public Health · doi:10.2105/ajph.79.3.340 · Cited by 2,208
Fractional Flow Reserve in Patients With Prior Myocardial Infarction
De Bruyne, B., Pijls, N. H. J., Bartunek, J., Kulecki, K., Bech, J.-W., De Winter, H., Van Crombrugge, P., Heyndrickx, G. R., & Wijns, W. (2001) · Circulation · doi:10.1161/01.cir.104.2.157 · Cited by 386
Self-citationWentzel, J. J., Krams, R., Schuurbiers, J. C. H., Oomen, J. A., Kloet, J., van der Giessen, W. J., Serruys, P. W., & Slager, C. J. (2001) · Circulation · doi:10.1161/01.cir.103.13.1740 · Cited by 335
Mudra, H., di Mario, C., de Jaegere, P., Figulla, H. R., Macaya, C., Zahn, R., Wennerblom, B., Rutsch, W., Voudris, V., Regar, E., et al. (2001) · Circulation · doi:10.1161/hc3701.096064 · Cited by 226
Mechanisms of Residual Lumen Stenosis After High-Pressure Stent Implantation
Bermejo, J., Botas, J., Garcı́a, E., Elı́zaga, J., Osende, J., Soriano, J., Abeytua, M., & Delcán, J. L. (1998) · Circulation · doi:10.1161/01.cir.98.2.112 · Cited by 92
Cited by
Writing Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention
Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., Hollenberg, S. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.007 · Cited by 2,164
ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., Whitlow, P. L., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.001 · Cited by 532
ACC/AHA/SCAI Practice Guidelines, February 21, 2006
(2006) · Circulation · doi:10.1161/circulationaha.106.173220 · Cited by 422
Metadata
- Authors
- Pijls, N. H. J., Klauss, V., Siebert, U., Powers, E., Takazawa, K., Fearon, W. F., Escaned, J., Tsurumi, Y., Akasaka, T., Samady, H., & De Bruyne, B.
- Venue
- Circulation
- Published
- 2002-06-25
- Volume
- 105
- Issue
- 25
- Pages
- 2950-2954
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2129548351
- Cited by
- 324
- References
- 6
- FWCI
- 14.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary Pressure Measurement After Stenting Predicts Adverse Events at Follow-Up: A Multicenter Registry. https://app.cochat.ai/papers/10.1161/01.cir.0000020547.92091.76
- The paper
- Pijls, N. H. J., Klauss, V., Siebert, U., Powers, E., Takazawa, K., Fearon, W. F., Escaned, J., Tsurumi, Y., Akasaka, T., Samady, H., & De Bruyne, B. (2002). Coronary Pressure Measurement After Stenting Predicts Adverse Events at Follow-Up: A Multicenter Registry. Circulation. https://doi.org/10.1161/01.cir.0000020547.92091.76
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.