Abstract

Background — In patients with complex pulmonary stenosis or atresia, a detailed delineation of all sources of pulmonary blood supply is necessary for planning surgical and transcatheter procedures and usually requires diagnostic cardiac catheterization. The goals of this study were to determine whether gadolinium-enhanced 3D magnetic resonance angiography (MRA) can provide a noninvasive alternative to diagnostic catheterization and to compare MRA and x-ray angiography measurements of pulmonary arteries and aortopulmonary collaterals (APCs). Methods and Results — Thirty-two patients with pulmonary stenosis or atresia (median age: 4.7 years, range: 1 day to 46.9 years) underwent both MRA and cardiac catheterization (median time: 1 month). Diagnoses included tetralogy of Fallot (TOF) with pulmonary atresia (n=13), TOF with pulmonary stenosis (n=4), post-Fontan palliation (n=5), and other complex congenital heart disease (n=10). Compared with catheterization and surgical observations, MRA had a 100% sensitivity and specificity for the diagnosis of main (n=10) and branch pulmonary artery (PA) stenosis or hypoplasia (n=38), as well as absent (n=5) or discontinuous (n=4) branch PAs. All 48 major APCs diagnosed by catheterization were correctly diagnosed by MRA. Three additional APCs were diagnosed by MRA but not by catheterization. The mean difference between MRA and catheterization measurements of 33 pulmonary vessel diameters was 0.5±1.5 mm, with a mean interobserver difference of 0.4±1.5 mm. Conclusions — Gadolinium-enhanced 3D MRA is a fast and accurate technique for delineation of all sources of pulmonary blood supply in patients with complex pulmonary stenosis and atresia and can be considered a noninvasive alternative to diagnostic catheterization with x-ray angiography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000023624.33478.18

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 245

Metadata

Authors
Geva, T., Greil, G. F., Marshall, A. C., Landzberg, M., & Powell, A. J.
Venue
Circulation
Published
2002-07-23
Volume
106
Issue
4
Pages
473-478
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2134137034
Cited by
245
References
1
FWCI
11.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gadolinium-Enhanced 3-Dimensional Magnetic Resonance Angiography of Pulmonary Blood Supply in Patients With Complex Pulmonary Stenosis or Atresia: Comparison With X-Ray Angiography. https://app.cochat.ai/papers/10.1161/01.cir.0000023624.33478.18
The paper
Geva, T., Greil, G. F., Marshall, A. C., Landzberg, M., & Powell, A. J. (2002). Gadolinium-Enhanced 3-Dimensional Magnetic Resonance Angiography of Pulmonary Blood Supply in Patients With Complex Pulmonary Stenosis or Atresia: Comparison With X-Ray Angiography. Circulation. https://doi.org/10.1161/01.cir.0000023624.33478.18

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).