Gadolinium-Enhanced 3-Dimensional Magnetic Resonance Angiography of Pulmonary Blood Supply in Patients With Complex Pulmonary Stenosis or Atresia: Comparison With X-Ray Angiography
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Background — In patients with complex pulmonary stenosis or atresia, a detailed delineation of all sources of pulmonary blood supply is necessary for planning surgical and transcatheter procedures and usually requires diagnostic cardiac catheterization. The goals of this study were to determine whether gadolinium-enhanced 3D magnetic resonance angiography (MRA) can provide a noninvasive alternative to diagnostic catheterization and to compare MRA and x-ray angiography measurements of pulmonary arteries and aortopulmonary collaterals (APCs). Methods and Results — Thirty-two patients with pulmonary stenosis or atresia (median age: 4.7 years, range: 1 day to 46.9 years) underwent both MRA and cardiac catheterization (median time: 1 month). Diagnoses included tetralogy of Fallot (TOF) with pulmonary atresia (n=13), TOF with pulmonary stenosis (n=4), post-Fontan palliation (n=5), and other complex congenital heart disease (n=10). Compared with catheterization and surgical observations, MRA had a 100% sensitivity and specificity for the diagnosis of main (n=10) and branch pulmonary artery (PA) stenosis or hypoplasia (n=38), as well as absent (n=5) or discontinuous (n=4) branch PAs. All 48 major APCs diagnosed by catheterization were correctly diagnosed by MRA. Three additional APCs were diagnosed by MRA but not by catheterization. The mean difference between MRA and catheterization measurements of 33 pulmonary vessel diameters was 0.5±1.5 mm, with a mean interobserver difference of 0.4±1.5 mm. Conclusions — Gadolinium-enhanced 3D MRA is a fast and accurate technique for delineation of all sources of pulmonary blood supply in patients with complex pulmonary stenosis and atresia and can be considered a noninvasive alternative to diagnostic catheterization with x-ray angiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches.
Prince, M. R., Narasimham, D. L., Stanley, J. C., Chenevert, T. L., Williams, D. M., Marx, M. V., & Cho, K. J. (1995) · Radiology · doi:10.1148/radiology.197.3.7480757 · Cited by 592
Complications associated with pediatric cardiac catheterization
Vitiello, R., McCrindle, B. W., Nykanen, D., Freedom, R. M., & Benson, L. N. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00396-9 · Cited by 401
Cardiac Surgery of the Neonate and Infant
Castañeda, A. R. (1994) · Cited by 399
Breath-hold, contrast-enhanced, three-dimensional MR angiography.
Leung, D. A., McKinnon, G. C., Davis, C. P., Pfammatter, T., Krestin, G. P., & Debatin, J. F. (1996) · Radiology · doi:10.1148/radiology.200.2.8685359 · Cited by 220
Reddy, V. M., McElhinney, D. B., Amin, Z., Moore, P., Parry, A. J., Teitel, D. F., & Hanley, F. L. (2000) · Circulation · doi:10.1161/01.cir.101.15.1826 · Cited by 200
Greil, G. F., Powell, A. J., Gildein, H. P., & Geva, T. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01730-2 · Cited by 179
Self-citationContrast-enhanced MR angiography: theory and optimization.
Prince, M. R. (1998) · PubMed · Cited by 96
CONTRAST-ENHANCED MR ANGIOGRAPHY
Prince, M. R. (1998) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00461-x · Cited by 86
Chung, T. (2000) · Pediatric Cardiology · doi:10.1007/s002469910004 · Cited by 65
Cited by
Feltes, T. F., Bacha, E., Beekman, R. H., Cheatham, J. P., Feinstein, J. A., Gomes, A. S., Hijazi, Z. M., Ing, F. F., de Moor, M., Morrow, W. R., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31821b1f10 · Cited by 853
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Geva, T., Sandweiss, B. M., Gauvreau, K., Lock, J. E., & Powell, A. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.045 · Cited by 620
Self-citationFratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-51 · Cited by 507
Self-citationHypoplastic Left Heart Syndrome
Feinstein, J. A., Benson, D. W., Dubin, A. M., Cohen, M. S., Maxey, D. M., Mahle, W. T., Pahl, E., Villafañe, J., Bhatt, A. B., Peng, L. F., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.022 · Cited by 503
Kilner, P. J., Geva, T., Kaemmerer, H., Trindade, P. T., Schwitter, J., & Webb, G. D. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp586 · Cited by 429
Self-citationSCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance
Leiner, T., Bogaert, J., Friedrich, M. G., Mohiaddin, R., Muthurangu, V., Myerson, S., Powell, A. J., Raman, S. V., & Pennell, D. J. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00682-4 · Cited by 328
Self-citationClinical Indications for Cardiovascular Magnetic Resonance (CMR): Consensus Panel Report #
Pennell, D., Sechtem, U., Higgins, C., Manning, W., Pohost, G., Rademakers, F., van Rossum, A., Shaw, L., & Kent Yucel, E. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200038581 · Cited by 274
Han, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
Sørensen, T. S., Körperich, H., Greil, G. F., Eichhorn, J., Barth, P., Meyer, H., Pedersen, E. M., & Beerbaum, P. (2004) · Circulation · doi:10.1161/01.cir.0000134282.35183.ad · Cited by 181
Self-citationBrown, D. W., Gauvreau, K., Powell, A. J., Lang, P., Colan, S. D., del Nido, P. J., Odegard, K. C., & Geva, T. (2007) · Circulation · doi:10.1161/circulationaha.107.723213 · Cited by 173
“Sustained desaturation* 24 (59) 0 (0) Acidosis (arterial pH 7.20) 11 (27) 1 (2)† Unplanned ICU admission 10 (24) 0 (0) Arrhythmia‡ 7 (17) 0 (0) Transient vascular injury 6 ( 15 ) 0 (0) Unplanned intubation 4 (10) 1 (2)† Initiation of inotropic support 3 (7) 0 (0) Heart block requiring pacing (24 h) 2 (5) 0 (0) Stridor…”
Self-citationValsangiacomo Buechel, E. R., Grosse-Wortmann, L., Fratz, S., Eichhorn, J., Sarikouch, S., Greil, G. F., Beerbaum, P., Bucciarelli-Ducci, C., Bonello, B., Sieverding, L., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu129 · Cited by 168
Self-citationCardiac MR Imaging Assessment Following Tetralogy of Fallot Repair
Norton, K. I., Tong, C., Glass, R. B. J., & Nielsen, J. C. (2006) · RadioGraphics · doi:10.1148/rg.261055064 · Cited by 67
“Three-dimensional MR angiography can provide a “road map” to aid in catheterization planning and, eventually, in surgical repair (Fig 4) (16).”
Giardini, A., Specchia, S., Coutsoumbas, G., Donti, A., Formigari, R., Fattori, R., Oppido, G., Gargiulo, G., & Picchio, F. M. (2006) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2006.01.012 · Cited by 51
Lin, M.-T., Wang, J.-K., Chen, Y.-S., Lee, W.-J., Chiu, H.-H., Chen, C.-A., Chiu, S.-N., Wu, E.-T., Lu, C.-W., Huang, S.-C., et al. (2012) · European Journal of Pediatrics · doi:10.1007/s00431-011-1621-4 · Cited by 34
“High sensitivity and specificity for the diagnosis of pulmonary arterial stenosis have also been demonstrated [11].”
Background
Metadata
- Authors
- Geva, T., Greil, G. F., Marshall, A. C., Landzberg, M., & Powell, A. J.
- Venue
- Circulation
- Published
- 2002-07-23
- Volume
- 106
- Issue
- 4
- Pages
- 473-478
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2134137034
- Cited by
- 245
- References
- 13
- FWCI
- 11.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.