Background— Radiofrequency catheter ablation (RFCA) is a promising intervention to treat atrial fibrillation. However, pulmonary vein (PV) stenosis after RFCA has been reported. The aim of this study was to investigate the incidence and time course of pulmonary vein stenosis after RFCA within a period of 3 months. Contrast-enhanced magnetic resonance angiography (MRA) was used to visualize pulmonary veins and was compared with radiographic angiography. Methods and Results— Forty-six consecutive patients with symptomatic paroxysmal atrial fibrillation had RFCA in the orifice of 138 pulmonary veins. Comparison of diameters measured in 44 untreated vessels either by radiographic angiography or with MRA established the reliability of MRA ( r =0.934). MRA measurements revealed an incidence of relevant diameter reductions of ≥25% or stenosis of ≥50% after RFCA of 25 of 138 (18.1%) treated vessels 1 day and/or 3 months after ablation. A progression of diameter reduction after RFCA was observed in 8.3% (maximum 75%), whereas a regression was observed in 6.3% of treated PVs. Ablation at a radial angle of >180° of a pulmonary vein orifice increased the risk of diameter reduction significantly compared with ablation at a radial angle ≤180° ( P =0.002). Conclusions— The occurrence and progression of PV stenosis is a potential significant complication of RFCA in the orifice of pulmonary veins. These findings may have an impact on the technical performance of this intervention. In addition, long-term studies will be necessary to evaluate lumen reduction over time. MRA is a noninvasive, reproducible imaging modality for this purpose.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000048146.81336.1d

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 193

Metadata

Authors
Dill, T., Neumann, T., Ekinci, O., Breidenbach, C., John, A., Erdogan, A., Bachmann, G., Hamm, C. W., & Pitschner, H.-F.
Venue
Circulation
Published
2003-02-18
Volume
107
Issue
6
Pages
845-850
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2014860870
Cited by
193
References
0
FWCI
16.55
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulmonary Vein Diameter Reduction After Radiofrequency Catheter Ablation for Paroxysmal Atrial Fibrillation Evaluated by Contrast-Enhanced Three-Dimensional Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1161/01.cir.0000048146.81336.1d
The paper
Dill, T., Neumann, T., Ekinci, O., Breidenbach, C., John, A., Erdogan, A., Bachmann, G., Hamm, C. W., & Pitschner, H.-F. (2003). Pulmonary Vein Diameter Reduction After Radiofrequency Catheter Ablation for Paroxysmal Atrial Fibrillation Evaluated by Contrast-Enhanced Three-Dimensional Magnetic Resonance Imaging. Circulation. https://doi.org/10.1161/01.cir.0000048146.81336.1d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.