Pulmonary Vein Diameter Reduction After Radiofrequency Catheter Ablation for Paroxysmal Atrial Fibrillation Evaluated by Contrast-Enhanced Three-Dimensional Magnetic Resonance Imaging
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background— Radiofrequency catheter ablation (RFCA) is a promising intervention to treat atrial fibrillation. However, pulmonary vein (PV) stenosis after RFCA has been reported. The aim of this study was to investigate the incidence and time course of pulmonary vein stenosis after RFCA within a period of 3 months. Contrast-enhanced magnetic resonance angiography (MRA) was used to visualize pulmonary veins and was compared with radiographic angiography. Methods and Results— Forty-six consecutive patients with symptomatic paroxysmal atrial fibrillation had RFCA in the orifice of 138 pulmonary veins. Comparison of diameters measured in 44 untreated vessels either by radiographic angiography or with MRA established the reliability of MRA ( r =0.934). MRA measurements revealed an incidence of relevant diameter reductions of ≥25% or stenosis of ≥50% after RFCA of 25 of 138 (18.1%) treated vessels 1 day and/or 3 months after ablation. A progression of diameter reduction after RFCA was observed in 8.3% (maximum 75%), whereas a regression was observed in 6.3% of treated PVs. Ablation at a radial angle of >180° of a pulmonary vein orifice increased the risk of diameter reduction significantly compared with ablation at a radial angle ≤180° ( P =0.002). Conclusions— The occurrence and progression of PV stenosis is a potential significant complication of RFCA in the orifice of pulmonary veins. These findings may have an impact on the technical performance of this intervention. In addition, long-term studies will be necessary to evaluate lumen reduction over time. MRA is a noninvasive, reproducible imaging modality for this purpose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975 · cited 1×
“To provide a systematic approach, the following ablation strategies were differentiated: (1) type A (TA), radiofrequency energy delivery at one spot or on an estimated radial angle of 90° within the orifice circumference of the PV; (2) type B (TB), radiofrequency energy delivery within the orifice of the PV on an esti…”
MethodChen, S.-A., Hsieh, M.-H., Tai, C.-T., Tsai, C.-F., Prakash, V. S., Yu, W.-C., Hsu, T.-L., Ding, Y.-A., & Chang, M.-S. (1999) · Circulation · doi:10.1161/01.cir.100.18.1879 · Cited by 1,446 · cited 2×
“To provide a systematic approach, the following ablation strategies were differentiated: (1) type A (TA), radiofrequency energy delivery at one spot or on an estimated radial angle of 90° within the orifice circumference of the PV; (2) type B (TB), radiofrequency energy delivery within the orifice of the PV on an esti…”
MethodPappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Vicedomini, G., Salvati, A., Dicandia, C., Mazzone, P., Santinelli, V., et al. (2000) · Circulation · doi:10.1161/01.cir.102.21.2619 · Cited by 1,358
Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation
Oral, H., Knight, B. P., Tada, H., Özaydın, M., Chugh, A., Hassan, S., Scharf, C., Lai, S. W. K., Greenstein, R., Pelosi, F., et al. (2002) · Circulation · doi:10.1161/hc0902.104712 · Cited by 1,112
Haïssaguerre, M., Jaïs, P., Shah, D. C., Garrigue, S., Takahashi, A., Lavergne, T., Hocini, M., Peng, J. T., Roudaut, R., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.101.12.1409 · Cited by 922
Pappone, C., Oreto, G., Rosanio, S., Vicedomini, G., Tocchi, M., Gugliotta, F., Salvati, A., Dicandia, C., Calabrò, M. P., Mazzone, P., et al. (2001) · Circulation · doi:10.1161/hc4601.098517 · Cited by 863
Pulmonary Vein Stenosis After Catheter Ablation of Atrial Fibrillation
Robbins, I. M., Colvin, E. V., Doyle, T. P., Kemp, W. E., Loyd, J. E., McMahon, W. S., & Kay, G. N. (1998) · Circulation · doi:10.1161/01.cir.98.17.1769 · Cited by 443
Natale, A., Pisano, E., Shewchik, J., Bash, D., Fanelli, R., Potenza, D., Santarelli, P., Schweikert, R., White, R., Saliba, W., et al. (2000) · Circulation · doi:10.1161/01.cir.102.16.1879 · Cited by 275
Pathological Effects of Extensive Radiofrequency Energy Applications in the Pulmonary Veins in Dogs
Taylor, G. W., Kay, G. N., Zheng, X., Bishop, S., & Ideker, R. E. (2000) · Circulation · doi:10.1161/01.cir.101.14.1736 · Cited by 239
YU, W., HSU, T., TAI, C., TSAI, C., HSIEH, M., LIN, W., LIN, Y., TSAO, H., DING, Y., CHANG, M., et al. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00887.x · Cited by 185
Cited by
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Calkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847
WRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 593
Circumferential Pulmonary Vein Isolation With the Cryoballoon Technique
Neumann, T., Vogt, J., Schumacher, B., Dorszewski, A., Kuniss, M., Neuser, H., Kurzidim, K., Berkowitsch, A., Koller, M., Heintze, J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.04.021 · Cited by 475
Self-citationVenice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Saad, E. B., Rossillo, A., Saad, C. P., Martin, D. O., Bhargava, M., Erciyes, D., Bash, D., Williams-Andrews, M., Beheiry, S., Marrouche, N. F., et al. (2003) · Circulation · doi:10.1161/01.cir.0000104569.96907.7f · Cited by 358
Oxley, T. J., Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Wheeler, T. L., Judy, J. W., McDonald, A. J., Dornom, A., Lovell, T. J. H., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3428 · Cited by 339
Clinical Indications for Cardiovascular Magnetic Resonance (CMR): Consensus Panel Report #
Pennell, D., Sechtem, U., Higgins, C., Manning, W., Pohost, G., Rademakers, F., van Rossum, A., Shaw, L., & Kent Yucel, E. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200038581 · Cited by 274
Kamat, A. M., Flaig, T. W., Grossman, H. B., Konety, B., Lamm, D., O'Donnell, M. A., Uchio, E., Efstathiou, J. A., & Taylor, J. A. (2015) · Nature Reviews Urology · doi:10.1038/nrurol.2015.58 · Cited by 252
Tse, H.-F., Reek, S., Timmermans, C., Lee, K. L.-F., Geller, J. C., Rodriguez, L.-M., Ghaye, B., Ayers, G. M., Crijns, H. J. G. M., Klein, H. U., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00788-5 · Cited by 200
Cardiovascular magnetic resonance imaging: Current and emerging applications
Lima, J. A. C., & Desai, M. Y. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.06.033 · Cited by 183
Haemers, P., Claus, P., & Willems, R. (2012) · Cardiology Research and Practice · doi:10.1155/2012/658937 · Cited by 7
“CMR allows sequential PV analysis without repeated radiation exposure and is comparable to radiographic angiography for the detection of PV stenosis [52].”
Method
Metadata
- Authors
- Dill, T., Neumann, T., Ekinci, O., Breidenbach, C., John, A., Erdogan, A., Bachmann, G., Hamm, C. W., & Pitschner, H.-F.
- Venue
- Circulation
- Published
- 2003-02-18
- Volume
- 107
- Issue
- 6
- Pages
- 845-850
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2014860870
- Cited by
- 193
- References
- 12
- FWCI
- 16.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.