The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Atrial High Rate Episodes Detected by Pacemaker Diagnostics Predict Death and Stroke: Report of the Atrial Diagnostics Ancillary Study of the MOde Selection Trial (MOST)
Open accessAbstract
Background— Some current pacing systems can automatically detect and record atrial tachyarrhythmias that may be asymptomatic. We prospectively studied a 312-patient (pt) subgroup of MOST (MOde Selection Trial), a 2010-patient, 6-year randomized trial of DDDR versus VVIR pacing in sinus node dysfunction (SND). The purpose of the study was to correlate atrial high rate events (AHREs) detected by pacemaker diagnostics with clinical outcomes. Methods and Results— Pacemakers were programmed to log an AHRE when the atrial rate was >220 bpm for 10 consecutive beats. Analysis was confined to patients with at least 1 AHRE duration exceeding 5 minutes. The 312 patients were median age 74 years, 55% female, and 60% had a history of SVT. 160 of 312 (51.3%) patients enrolled had at least 1 AHRE >5 minutes duration over median follow-up of 27 months. Cox proportional hazards analysis assessed the relationship of AHREs with clinical events, adjusting for prognostic variables and baseline covariates. The presence of any AHRE was an independent predictor of the following: total mortality (hazard ratio AHRE versus no AHRE and 95% confidence intervals=2.48 [1.25, 4.91], P =0.0092); death or nonfatal stroke (2.79 [1.51, 5.15], P =0.0011); and atrial fibrillation (5.93 [2.88, 12.2], P =0.0001). There was no significant effect of pacing mode on the presence or absence of AHREs. Conclusions— AHRE detected by pacemakers in patients with SND identify patients that are more than twice as likely to die or have a stroke, and 6 times as likely to develop atrial fibrillation as similar patients without AHRE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Several studies have shown an increased risk of thromboembolic events in patients with atrial arrhythmias detected by device diagnostics.59,60”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [60]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer series in statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,239
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
The Statistical Analysis of Failure Time Data.
Aitkin, M. A., Kalbfleisch, J. D., & Prentice, R. L. (1981) · Biometrics · doi:10.2307/2530581 · Cited by 9,875
Impact of Atrial Fibrillation on the Risk of Death: The Framingham Heart Study
Benjamin, E. J., Wolf, P. A., D’Agostino, R. B., Silbershatz, H., Kannel, W. B., & Levy, D. (1998) · Circulation · doi:10.1161/01.cir.98.10.946 · Cited by 4,575
Risk Factors for Stroke and Efficacy of Antithrombotic Therapy in Atrial Fibrillation
(1994) · Archives of Internal Medicine · doi:10.1001/archinte.154.13.1449 · Cited by 2,643
Atrial Fibrillation: A Major Contributor to Stroke in the Elderly: The Framingham Study
Wolf, P. A. (1987) · Archives of Internal Medicine · doi:10.1001/archinte.1987.00370090041008 · Cited by 1,108
Ventricular Pacing or Dual-Chamber Pacing for Sinus-Node Dysfunction
Lamas, G. A., Lee, K. L., Sweeney, M. O., Silverman, R., León, A. R., Yee, R. K., Marinchak, R. A., Flaker, G., SCHRON, E. B., Orav, E. J., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013040 · Cited by 994
Self-citationPathophysiology and Prevention of Atrial Fibrillation
Allessie, M. A., Boyden, P. A., Camm, A. J., Kléber, A. G., Lab, M. J., Legato, M. J., Rosen, M. R., Schwartz, P. J., Spooner, P. M., Wagoner, D. R. V., et al. (2001) · Circulation · doi:10.1161/01.cir.103.5.769 · Cited by 724
Cited by
Sorted by citations
Items 601–700 of 749
Jones, M., & Williams, E. M. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03430.x · Cited by 1
Temporal changes in diastolic function in heart failure patients with restrictive filling
Maeder, M. T., Gamboni, S. E., & Kaye, D. M. (2010) · International Journal of Cardiology · doi:10.1016/j.ijcard.2010.10.060 · Cited by 1
Arrhythmias preceding death documented by postmortem pacemaker interrogation
Moubarak, G., Polivka, M., & Lacaze-Gadonneix, J. (2010) · International Journal of Cardiology · doi:10.1016/j.ijcard.2010.10.059 · Cited by 1
Anticoagulation Management in Patients with Pacemaker-Detected Atrial Fibrillation
Poposka, L., Boskov, V., Risteski, D., Taleski, J., & Georgievska‐Ismail, L. (2016) · Open Access Macedonian Journal of Medical Sciences · doi:10.3889/oamjms.2016.053 · Cited by 2
“AF can be very efficiently detected in patients with implanted pacemaker and the detection of atrial high rate episodes (AHRE) - defined as episodes of atrial frequency ≥220 bpm, lasting ≥5 minutes, has been proven to be an independent predictor of death or nonfatal stroke in these patients [7].”
BackgroundSymptoms of Atrial Fibrillation
Dadkhah, S., & Sharain, K. (2016) · Contemporary cardiology · doi:10.1007/978-3-319-31386-3_5 · Cited by 1
Home Screening for Detecting Subclinical Atrial Fibrillation.
Ricci, R. P., & Glotzer, T. V. (2015) · PubMed Central · doi:10.4022/jafib.1326 · Cited by 1
Self-citationApproach to device-detected subclinical atrial fibrillation
van Zyl, M., McLeod, C. J., & Gersh, B. J. (2017) · SA Heart · doi:10.24170/14-2-2497 · Cited by 1
Tanaka, M. H., Su, K., Maki-Oi, M., Motohashi, Y., Takahashi, K., Ko, E., Hanazawa, K., Toyofuku, M., Kitada, M., Yuzuki, Y., et al. (2016) · PubMed Central · doi:10.4022/jafib.1435 · Cited by 1
The additional value of an algorithm for atrial fibrillation at the stroke unit
van der Maten, G., Plas, G. J. J., Meijs, M. F. L., Brouwers, P. J. A. M., Brusse-Keizer, M. G. J., & den Hertog, H. M. (2020) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2020.104930 · Cited by 2
“There is growing evidence suggesting the risk of stroke increases with longer AF duration.(21) 25 A benefit of oral anticoagulation in patients with AF duration less than one to several minutes, has not been shown yet.”
BackgroundFeasibility of digital atrial fibrillation screening in an elderly population
Birkemeyer, R., Maisch, L., Dahme, T., Spieß, J., Althaus, K., Schneider, S., Ravens, U., Haase, D., & Schotten, U. (2021) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-021-00783-2 · Cited by 1
Gala, A. R. P. B. E., Pope, M., Leo, M., Sharp, A. J., Tsoi, V., Paisey, J., Curzen, N. P., & Betts, T. R. (2023) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2022.22 · Cited by 1
Hoşoğlu, Y., Akkaya, F., & Kırış, A. (2023) · The European Research Journal · doi:10.18621/eurj.1180149 · Cited by 1
Management of Device Detected Subclinical Atrial Fibrillation
SALMON, T. W., Calvert, P. A. R., & Lip, G. Y. H. (2024) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-024-00748-3 · Cited by 1
“…which falls in line with the results of ARTESiA and NOAH-AFNET 6, in addition to aforementioned studies on stroke risk in this population [12, 14–18 , Regarding major bleeding, the magnitude of risk observed in both ARTESiA and NOAH-AFNET 6 trials is consistent with previous trials of…”
Jaroonpipatkul, S., Sathapanasiri, T., Maliang, C., Pokawattana, A., & Navaravong, L. (2024) · Cureus · doi:10.7759/cureus.75380 · Cited by 1
Refining Stroke Risk Assessment in Patients with Device-Detected Atrial Fibrillation
Sjøholm-Christensen, A., Tojaga, N., & Brandes, A. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm14010082 · Cited by 1
Pacemaker Therapy in Atrial Fibrillation
Park, S. (2019) · doi:10.17303/jcvm.2013.1.102 · Cited by 1
Continuous Monitoring of Atrial Fibrillation in Heart Failure
Herweg, B., Barold, S. S., & Steinberg, J. S. (2013) · Heart Failure Clinics · doi:10.1016/j.hfc.2013.06.002 · Cited by 1
Control intraoperatorio de la ablación de arritmias. Recurrencias
Hornero, F., & Atienza, F. (2010) · Cirugía Cardiovascular · doi:10.1016/s1134-0096(10)70099-1 · Cited by 1
“La monitorización del ritmo auricular con marcapasos ha mostrado que sólo los episodios de FA mayo-res de 5 min están asociados a complicaciones cardiovasculares 35-37 .”
Atrial Fibrillation and Related Disorders
Ricciotti, J., & Menditto, A. (2015) · Springer eBooks · doi:10.1007/978-3-319-19926-9_20 · Cited by 1
Subclinical atrial fibrillation: A new entity and what it means?
Ott, P. (2016) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2016.07.031 · Cited by 1
Park, S. (2016) · International Journal of Arrhythmia · doi:10.18501/arrhythmia.2016.028 · Cited by 1
Hemodynamic instability after pulmonary veins isolation in a patient with dual chamber pacemaker
Kiuchi, M. G., Lobato, G. M., & Chen, S. (2017) · Medicine · doi:10.1097/md.0000000000007060 · Cited by 1
Kiuchi, M. G., & Chen, S. (2017) · Hipertensión y Riesgo Vascular · doi:10.1016/j.hipert.2017.05.003 · Cited by 1
Are Older Adults Willing to Consider New Strategies to Reduce Stroke Risk?
Grande, S. W., O’Neill, E. S., Sherman, A. E., & Coylewright, M. J. (2017) · Qualitative Health Research · doi:10.1177/1049732317720682 · Cited by 1
Screening for atrial fibrillation
Tlegenova, Z. S., Kudaiberdieva, G., Zholdin, B., & Abdrakhmanov, A. S. (2018) · Journal of Clinical Medicine of Kazakhstan · doi:10.23950/1812-2892-jcmk-00542 · Cited by 1
The Role of Antithrombotic Therapy in Heart Failure
Chrysohoou, C. A., Magkas, N., Antoniou, C. K., Manolakou, P., Laina, A., & Tousoulis, D. M. (2020) · Current Pharmaceutical Design · doi:10.2174/1381612826666200531151823 · Cited by 1
Cardiac diagnostic work-up of ischaemic stroke
Yang, H., Nassif, M., Khairy, P., de Groot, J. R., Roos, Y. B. W. E. M., de Winter, R. J., Mulder, B. J. M., & Bouma, B. J. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw414 · Cited by 4
Fung, J. W., & Yu, C. (2010) · Circulation Journal · doi:10.1253/circj.cj-10-1042 · Cited by 1
Healey, J. S., Brambatti, M., Gold, M. R., Morillo, C. A., Capucci, A., Muto, C., Lau, C., Gelder, I. C. V., Hohnloser, S. H., Carlson, M. D., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.012885 · Cited by 1
Does Absence (of AF) Make the Heart Grow Fonder?
Flaker, G., & Weachter, R. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01348.x · Cited by 1
Future prospects for implantable devices for atrial defibrillation
Tse, H., & Lau, C. (2004) · Cardiology Clinics · doi:10.1016/s0733-8651(03)00114-0 · Cited by 1
Devices for the Management of Atrial Fibrillation
JUNG, W. (2005) · Elsevier eBooks · doi:10.1016/b978-0-443-06570-5.50047-2 · Cited by 1
Mazurek, M., & Lip, G. Y. H. (2017) · European Heart Journal Acute Cardiovascular Care · doi:10.1177/2048872616688455 · Cited by 1
Stroke and atrial fibrillation: better detection, effects on infarct evolution and outcome
Tu, H. T. H. (2018) · Minerva Access (University of Melbourne) · Cited by 1
The Naissance of Atrial Fibrillation
Glotzer, T. V. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.10.007 · Cited by 1
Self-citationMiranda‐Arboleda, A. F., & Baranchuk, A. M. (2022) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2022.09.007 · Cited by 1
Understanding and Managing the Impact of Atrial High-Rate Episodes: Still a Work in Progress
Trohman, R. G. (2023) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2023.07.117 · Cited by 1
Healey, J. S., & Wong, J. A. (2024) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2024.01.025 · Cited by 1
Subclinical atrial fibrillation
Benezet‐Mazuecos, J., & Healey, J. S. (2025) · Medicina Clínica (English Edition) · doi:10.1016/j.medcle.2025.107104 · Cited by 1
Fibrillation atriale infraclinique
Lenormand, T., Bisson, A., & Fauchier, L. (2024) · Archives des Maladies du Coeur et des Vaisseaux - Pratique · doi:10.1016/j.amcp.2024.09.002
Curiosità in Cardiostimolazione: rassegna di tecnologia e casi clinici (parte III)
CORBUCCI, G., Sciotto, F., Riva, U., Trombetti, M., & Venturini, D. (2003) · Giornale Italiano di Aritmologia e Cardiostimolazione
Therapeutische, antitachykarde Schrittmacher- und Defibrillatortherapie
Jung, W. (2007) · Steinkopff eBooks · doi:10.1007/978-3-7985-1748-6_13
Guzmán, J. C., & Morillo, C. A. (2014) · Springer eBooks · doi:10.1007/978-3-319-09102-0_22
Asymptomatic atrial fibrillation and pacemaker diagnostics: The unseen presence
Ellenbogen, K. A., & Wood, M. A. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2004.11.005
The Impact of Early Detection of Atrial Fibrillation on Stroke Outcomes
Tomson, T. T., Greenland, P., & PASSMAN, R. S. (2014) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.10.008
Is a Dual-Chamber ICD Always Better in Patients Requiring an ICD?
Sullivan, R. M., & Olshansky, B. (2011) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2011.08.003
How early is early enough to prevent stroke in atrial fibrillation?
Guo, Y., Lip, G. Y. H., & Apostolakis, S. Z. (2012) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.12.36
Sekundärprophylaxe des ischämischen Schlaganfalls
Schwab, S., & Breuer, L. (2014) · Nervenheilkunde · doi:10.1055/s-0038-1627667
Stroke and Bleeding Risks in Patients with Atrial Fibrillation
Maan, A., Ruskin, J. N., & Heist, E. K. (2014) · Interventional Cardiology Clinics · doi:10.1016/j.iccl.2013.11.001
Cryptogenic stroke: atrial fibrillation under indictment
Jorfida, M., & Cerrato, P. (2009) · Emergency Care Journal · doi:10.4081/ecj.2009.3.32
Anderson, J. L. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00639.x
Value of implantable cardioverter-defibrillators in managing atrial fibrillation
Frisch, D. R. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.10.009
Santulli, G., Massimo Chiariello, A., D'Ascia, C., & D’Ascia, S. L. (2012) · Nature Precedings · doi:10.1038/npre.2012.7137.1
“(D'Ascia et al., 2009) AF was defined as an episode, with or without symptoms, lasting at least 10 minutes,(Fung et al., 2005; Glotzer et al., 2003) similar to a large substudy of the CARE-HF trial reported by Hoppe et al.(Hoppe et al., 2006) Patients were also assessed for HF symptoms (NYHA…”
MethodRemote Monitoring for Atrial Fibrillation
Man, J. P., Kapa, S., & Dixit, S. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.05.008
Ip, J. H., & Halperin, J. L. (2011) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2011.08.006
Atrial fibrillation in cardiac implantable electronic devices and the duck test
Benezet‐Mazuecos, J., Campal, J. M. R., & Farré, J. (2014) · American Heart Journal · doi:10.1016/j.ahj.2014.02.004
Rordorf, R., Vicentini, A., & Landolina, M. (2008) · Giornale italiano di cardiologia · doi:10.1714/675.7858
Device-Detected Atrial Fibrillation: Perils and Pitfalls
Contractor, T. A., Patel, M. B., & Thakur, R. K. (2011) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2011.07.003
Prolonged Rhythm Monitoring in the Patient with Stroke and Transient Ischemic Attack
Seet, R. C. S., & Rabinstein, A. A. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.05.006
Asymptomatic Atrial Fibrillation After Cryptogenetic Stroke
Raviele, A. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.002835
“The prevalence of silent AF varies in different clinical settings, ranging from 0% to 31% in postablation patients(12,13) to 16% to 25% as incidental finding at standard ECG,(2,14) 54% to 70% in patients treated with antiarrhythmic drugs, and 15,16 up to 51% to 74% in pacemaker/implantable cardioverterdefibrillator re…”
BackgroundManaging heart failure better: the value of implantable device data.
Best, J. F., Feldker, H., Aggarwal, K. B., & Tejwani, L. (2008) · PubMed
ASymptomatic AF and Stroke Evaluation in Pacemaker Patients and the AF Reduction Atrial Pacing Trial
Connolly, S. J., Hohnloser, S. H., Morillo, C. A., Healey, J. S., Israel, C. W., Lade, K., Gold, M. R., Fain, E. S., & Capucci, A. (2004)
Should Atrial Fibrillation Burden Be A Feature to Guide Thromboembolism Prophylaxis?
Sachdev, M., & Daoud, E. G. (2012) · Europe PMC (PubMed Central) · doi:10.4022/jafib.530
German Atrial Fibrillation Competence NETwork and the European Heart Rhythm Association
Kirchhof, P. F., Auricchio, A., Bax, J. J., Crijns, H. J. G. M., Camm, A. J., Diener, H., Goette, A., Hindricks, G., Hohnloser, S. H., Kück, K., et al. (2007)
Kennedy, H. S., Wadas, T. M., Reyes, G. S., & Panday, M. (2014) · PubMed Central · doi:10.4022/jafib.1127
Follow‐up after ablation: assessing success, symptom status, and recurrent arrhythmias
Kircher, S., Eitel, C., & Hindricks, G. (2015) · Wiley eBooks · doi:10.1002/9781118658369.ch24
Atrial detection and timing for atrioventricular synchronous pacing
Pakarinen, S. (2013) · Työväentutkimus Vuosikirja
Vaksmann, A., Finat, L., Boulé, S., Kouakam, C., Marquié, C., Brigadeau, F., Klug, D., Lacroix, D., & Guédon-Moreau, L. (2016) · European Research in Telemedicine / La Recherche Européenne en Télémédecine · doi:10.1016/j.eurtel.2016.02.001
Thomas, H. E., Cunnington, M. S., & McComb, J. M. (2011) · Reviews in Clinical Gerontology · doi:10.1017/s0959259811000086
Reversible cardiomyopathy after radiofrequency ablation of 30-year persistent atrial tachycardia
Suzuki, A., Shiga, T., Arai, K., & Shoda, M. (2013) · BMJ Case Reports · doi:10.1136/bcr-2013-008727
Długoterminowe monitorowanie holterowskie — rodzaje i znaczenie kliniczne
Krawczyńska, A., Średniawa, B., Cebula, S., Musialik-Lydka, A., Kowalski, O., Lenarczyk, R., Woźniak, A., Tabor, K., & Kalarus, Z. F. (2010) · Folia Cardiologica
Healey, J. S., Martin, J. L., Duncan, A., Connolly, S. J., Ha, A. H., Morillo, C. A., Nair, G. M., Eikelboom, J. W., & Dokainish, H. (2013)
The Value of Implantable Cardioverter-Defibrillators in Managing Atrial Fibrillation
Frisch, D. R. (2009) · The Medicine Forum
Meesmann, M. (2013) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-013-0269-3
Electrical Therapy for Bradycardia
Kusumoto, F. M., & Goldschlager, N. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00040-5
Pitfalls in the Acute Management of Atrial Fibrillation
Winchester, D. E., Kaufmann, M. R., McKillop, M., & Miles, W. M. (2016) · Contemporary cardiology · doi:10.1007/978-3-319-31386-3_14
Diagnostic Aspects of Implantable Devices
Ziegler, P., Hettrick, D. A., Padeletti, L., & Saksena, S. V. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00091-0
Pacemaker Patients with High Level of Risk
Sabr, A. (2016) · IJIREEICE · doi:10.17148/ijireeice.2016.4357
Atrial Fibrillation and the Risk of Stroke
Patel, P. J., & Deo, R. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003367
Fibrilación auricular en pacientes con dispositivos cardiacos electrónicos implantables
Akerström, F. O., Pachón, M., Puchol, A., Pérez, A. S., & Arias, M. A. (2016) · Revista Española de Cardiología Suplementos · doi:10.1016/s1131-3587(16)30014-0
Muscente, F., & Caterina, R. D. (2016) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000475
Is antithrombotic therapy necessary for short self-limiting episodes of atrial fibrillation?
Stazi, D. F. (2016) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000466
Pacing and Defibrillation for Atrial Arrhythmias
Cooper, J. M. (2009) · Humana Press eBooks · doi:10.1007/978-1-59745-424-7_8
Roşianu, Ş. H., Buzoianu, A. D., Roşianu, A., & Capalneanu, R. (2011)
Surapaneni, P. K., Safadi, A. R., Contractor, T. A., Patel, M., & Thakur, R. K. (2016)
THE UNRESOLVED ISSUES AND MODERN VIEW ON ATRIAL FIBRILLATION PATIENTS MANAGEMENT
Losik, D., Афгановна, Б. С., Анатольевич, П. Е., Mikheenko, I., Шабанов, В. В., & Romanov, A. B. (2017) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2017-7-162-170
Can Implantable Cardiac Devices Be Used to Lower Risk of Stroke?
Wasserlauf, J., & PASSMAN, R. S. (2017) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-017-0554-5
Que faire devant des arythmies aux mémoires holter des stimulateurs et défibrillateurs cardiaques ?
Amara, W. (2017) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2017.09.020
Ozcan, E., Kudaiberdieva, G., & Görenek, B. (2017) · Heart Vessels and Transplantation · doi:10.24969/hvt.2017.27
“Nevertheless, it should be kept in mind that the minimum duration of AHRE that increases thromboembolic risk is not certain.”
BackgroundInfluentialClinical Trials of Pacing Modes
Healey, J. S., Morillo, C. A., & Connolly, S. J. (2007) · Elsevier eBooks · doi:10.1016/b978-1-4160-2536-8.50015-7
Subclinical Atrial Fibrillation
Sharma, A., & Lópes, R. D. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-55429-9.00005-4
Healey, J. S. (2018) · Canadian Journal of General Internal Medicine · doi:10.22374/cjgim.v13isp1.314
Detection of Ventricular Tachycardia for Patient through Remote Continuous Health Devices
Kopperundevi, N., Pavithra, P., Priya, K. K., E, S. P. S. E., & Sathya, C. (2018)
Heart and Embolic Stroke of Undetermined Source
Cavallini, A. M., Magno, S., Persico, A., & Morotti, A. (2019) · Springer eBooks · doi:10.1007/978-3-319-90305-7_35-1
Anticoagulants for subclinical atrial fibrillation
Sazonova, Y. S., Andreev, D. A., Al, S., Serova, M. V., & Samoylenko, I. V. (2019) · Russian Journal of Cardiology and Cardiovascular Surgery · doi:10.17116/kardio201912051441
Cao, S., Zhu, X., & Xia, M. (2020) · Circulation · doi:10.1161/circulationaha.119.044621
The Research Progress of Cardiac Implantable Electronic Device-Identified Atrial Fibrillation
卢, 江. (2020) · Advances in Clinical Medicine · doi:10.12677/acm.2020.103036
Device-Detected Subclinical Atrial Fibrillation: The Anesthesiologist's Perspective
Ghia, S., Mehta, D., & Bhatt, H. V. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2020.05.036
Metadata
- Authors
- Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., Lee, K. L., & Lamas, G. A.
- Affiliations
- Brigham and Women's Hospital (US)
- Venue
- Circulation
- Published
- 2003-04
- Volume
- 107
- Issue
- 12
- Pages
- 1614-1619
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2149989524
- Cited by
- 750
- References
- 28
- Citations by year
- 2026: 16 · 2025: 21 · 2024: 31 · 2023: 26 · 2022: 23 · 2021: 50 · 2020: 38 · 2019: 50 · 2018: 52 · 2017: 64 · 2016: 56 · 2015: 46 · 2014: 44 · 2013: 32 · 2012: 34
- FWCI
- 12.56
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Medtronic
- National Institutes of Health (5u01hl053973-05, 5u01hl055981-05)
- National Heart, Lung, and Blood Institute (HL 53973, U01HL049804, U01 HL 53973, U01-HL-49804, U01-HL-55981)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- atrial high-rate episodes, atrial tachyarrhythmia, sick sinus syndrome, DDDR pacing, VVIR pacing, mode choice, atrial fibrillation, mortality, stroke, prognostic factors, asymptomatic arrhythmia
- MeSH terms
- Adult, Aged, Arrhythmias, Cardiac, Arrhythmia, Sinus, Atrial Fibrillation, Cardiac Pacing, Artificial, Female, Heart Atria, Humans, Male, Middle Aged, Electrocardiography, Ambulatory, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review