The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Pacing-Induced Spontaneous Activity in Myocardial Sleeves of Pulmonary Veins After Treatment With Ryanodine
Open accessAbstract
Background— Recent clinical electrophysiology studies and successful results of radiofrequency catheter ablation therapy suggest that high-frequency focal activity in the pulmonary veins (PVs) plays important roles in the initiation and perpetuation of atrial fibrillation, but the mechanisms underlying the focal arrhythmogenic activity are not understood. Methods and Results— Extracellular potential mapping of rabbit right atrial preparations showed that ryanodine (2 μmol/L) caused a shift of the leading pacemaker from the sinoatrial node to an ectopic focus near the right PV-atrium junction. The transmembrane potential recorded from the isolated myocardial sleeve of the right PV showed typical atrial-type action potentials with a stable resting potential under control conditions. Treatment with ryanodine (0.5 to 2 μmol/L) resulted in a depolarization of the resting potential and a development of pacemaker depolarization. These changes were enhanced transiently after an increase in the pacing rate: a self-terminating burst of spontaneous action potentials (duration, 33.6±5.0 s; n=32) was induced by a train of rapid stimuli (3.3 Hz) applied after a brief rest period. The pacing-induced activity was attenuated by either depletion of the sarcoplasmic reticulum of Ca 2+ or blockade of the sarcolemmal Na + -Ca 2+ exchanger or Cl − channels and potentiated by β-adrenergic stimulation. Conclusions— PV myocardial sleeves have the potential to generate spontaneous activity, and such arrhythmogenic activity is uncovered by modulation of intracellular Ca 2+ dynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sinoatrial node, a heterogeneous pacemaker structure
Boyett, M. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00135-8 · Cited by 698
Self-citation
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273
Ehrlich, J. R., Cha, T., Zhang, L., Chartier, D., Melnyk, P. M., Hohnloser, S. H., & Stanley (2003) · The Journal of Physiology · doi:10.1111/j.1469-7793.2003.00801.x · Cited by 286
Metadata
- Authors
- Honjo, H., Boyett, M. R., Niwa, R., Inada, S., Yamamoto, M., Mitsui, K., Horiuchi, T., Shibata, N., Kamiya, K., & Kodama, I.
- Venue
- Circulation
- Published
- 2003-04-15
- Volume
- 107
- Issue
- 14
- Pages
- 1937-1943
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2022925863
- Cited by
- 171
- References
- 1
- FWCI
- 9.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pacing-Induced Spontaneous Activity in Myocardial Sleeves of Pulmonary Veins After Treatment With Ryanodine. https://app.cochat.ai/papers/10.1161/01.cir.0000062645.38670.bd
- The paper
- Honjo, H., Boyett, M. R., Niwa, R., Inada, S., Yamamoto, M., Mitsui, K., Horiuchi, T., Shibata, N., Kamiya, K., & Kodama, I. (2003). Pacing-Induced Spontaneous Activity in Myocardial Sleeves of Pulmonary Veins After Treatment With Ryanodine. Circulation. https://doi.org/10.1161/01.cir.0000062645.38670.bd
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.