Strain-Rate Imaging During Dobutamine Stress Echocardiography Provides Objective Evidence of Inducible Ischemia
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Background— Interpretation of dobutamine stress echocardiography (DSE) is subjective and strongly dependent on the skills of the reader. Strain-rate imaging (SRI) by tissue Doppler may objectively analyze regional myocardial function. This study investigated SRI markers of stress-induced ischemia and analyzed their applicability in a clinical setting. Methods and Results— DSE was performed in 44 patients with known or suspected coronary artery disease. Simultaneous perfusion scintigraphy served as a “gold standard” to define regional ischemia. All patients underwent coronary angiography. Segmental strain and strain rate were analyzed at all stress levels by measuring amplitude and timing of deformation and visual curved M-mode analysis. Results were compared with conventional stress echo reading. In nonischemic segments, peak systolic strain rate increased significantly with dobutamine stress (−1.6±0.6 s −1 versus −3.4±1.4 s −1 , P <0.01), whereas strain during ejection time changed only minimally (−17±6% versus −16±9%, P <0.05). During DSE, 47 myocardial segments in 19 patients developed scintigraphy-proven ischemia. Strain-rate increase (−1.6±0.8 s −1 versus −2.0±1.1 s −1 , P <0.05) and strain (−16±7% versus −10±8%, P <0.05) were significantly reduced (both P <0.01 compared with nonischemic). Postsystolic shortening (PSS) was found in all ischemic segments. The ratio of PSS to maximal segmental deformation was the best quantitative parameter to identify stress-induced ischemia. Compared with conventional readings, SRI curved M-mode assessment improved sensitivity/specificity from 81%/82% to 86%/90%. Conclusions— During DSE, SRI quantitatively and qualitatively differentiates ischemic and nonischemic regional myocardial response to dobutamine stress. The ratio of PSS to maximal strain may be used as an objective marker of ischemia during DSE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Urheim, S., Edvardsen, T., Torp, H., Angelsen, B., & Smiseth, O. A. (2000) · Circulation · doi:10.1161/01.cir.102.10.1158 · Cited by 1,078
Real-Time Strain Rate Imaging of the Left Ventricle by Ultrasound
Heimdal, A., Støylen, A., Torp, H., & Skjærpe, T. (1998) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(98)70151-8 · Cited by 850
Hoffmann, R., Lethen, H., Marwick, T., Arnese, M., Fioretti, P., Pingitore, A., Picano, E., Buck, T., Erbel, R., Flachskampf, F. A., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00483-1 · Cited by 589
Self-citationMethodology, Feasibility, Safety and Diagnostic Accuracy of Dobutamine Stress Echocardiography
Geleijnse, M. L., Fioretti, P. M., & Roelandt, J. R. T. C. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00206-4 · Cited by 485
Weidemann, F., Jamal, F., Sutherland, G. R., Claus, P., Kowalski, M., Hatle, L., De Scheerder, I., Bijnens, B., & Rademakers, F. E. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00025.2002 · Cited by 407
Voigt, J., Lindenmeier, G., Exner, B., Regenfus, M., Werner, D., Reulbach, U., Nixdorff, U., Flachskampf, F. A., & Daniel, W. G. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00111-1 · Cited by 309
Self-citationPellikka, P. A., Roger, V. L., Oh, J. K., Miller, F. A., Seward, J. B., & Tajik, A. J. (1995) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(11)64660-0 · Cited by 219
Voigt, J.-U., Arnold, M. F., Karlsson, M., Hübbert, L., Kukulski, T., Hatle, L., & Sutherland, G. R. (2000) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2000.105631 · Cited by 198
Self-citationJamal, F., Strotmann, J., Weidemann, F., Kukulski, T., D’hooge, J., Bijnens, B., Van de Werf, F., De Scheerder, I., & Sutherland, G. R. (2001) · Circulation · doi:10.1161/hc3501.093818 · Cited by 198
Hoffmann, R., Marwick, T. H., Poldermans, D., Lethen, H., Ciani, R., van der Meer, P., Tries, H.-P., Gianfagna, P., Fioretti, P., Bax, J. J., et al. (2002) · European Heart Journal · doi:10.1053/euhj.2001.2968 · Cited by 142
Strain Rate Imaging by Ultrasonography in the Diagnosis of Coronary Artery Disease
Støylen, A., Heimdal, A., Bjørnstad, K., Wiseth, R., Vik‐Mo, H., Torp, H. G., Angelsen, B., & Skjærpe, T. (2000) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2000.106573 · Cited by 130
Regional asynchrony during acute myocardial ischemia quantified by ultrasound strain rate imaging
Pislaru, C., Bëlohlávek, M., Bae, R. Y., Abraham, T. P., Greenleaf, J. F., & Seward, J. B. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01113-5 · Cited by 127
Abraham, T. P., Bëlohlávek, M., Thomson, H. L., Pislaru, C., Khandheria, B. K., Seward, J. B., & Pellikka, P. A. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01768-0 · Cited by 107
How accurate is dobutamine stress electrocardiography for detection of coronary artery disease?
Mairesse, G. H., Marwick, T. H., Vanoverschelde, J., Baudhuin, T., Wijns, W. C., Melin, J. A., & Detry, J.-M. R. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90850-8 · Cited by 102
Cited by
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Self-citationLang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev014 · Cited by 8,361
Self-citation2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Self-citationRecommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Self-citation
Metadata
- Authors
- Voigt, J.-U., Exner, B., Schmiedehausen, K., Huchzermeyer, C., Reulbach, U., Nixdorff, U., Platsch, G., Kuwert, T., Daniel, W. G., & Flachskampf, F. A.
- Venue
- Circulation
- Published
- 2003-04-29
- Volume
- 107
- Issue
- 16
- Pages
- 2120-2126
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2006308176
- Cited by
- 415
- References
- 14
- FWCI
- 12.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.