Randomized Evaluation of Polytetrafluoroethylene-Covered Stent in Saphenous Vein Grafts: The Randomized Evaluation of polytetrafluoroethylene COVERed stent in Saphenous vein grafts (RECOVERS) Trial
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background— Treatment of lesions located in saphenous vein grafts (SVGs) is associated with increased procedural risk and a high rate of restenosis. Methods and Results— We conducted a randomized, multicenter trial to evaluate the usefulness of a polytetrafluoroethylene (PTFE)-covered stent compared with a bare stainless steel (SS) stent for prevention of restenosis and major adverse cardiac events (MACE) in patients undergoing SVG treatment. The primary end point was angiographic restenosis at 6 months. Secondary end points were 30-day and 6-month MACE rates, defined as the cumulative of death, myocardial infarction (MI), and target lesion revascularization. Between September 1999 and January 2002, 301 patients with SVG lesions were randomized to either the PTFE-covered JoStent coronary stent graft (PTFE group, n=156) or the SS JoFlex stent (control group, n=145). Angiographic and procedural success rates were similar between the 2 groups (97.4% versus 97.9% and 87.3% versus 93.8%, respectively). The incidence of 30-day MACE was higher in the PTFE group (10.9% versus 4.1%, P =0.047) and was mainly attributed to MI (10.3% versus 3.4%, P =0.037). The primary end point, the restenosis rate at 6-month follow-up, was similar between the 2 groups (24.2% versus 24.8%, P =0.237). Although the 6-month non–Q-wave MI rate was higher in the PTFE group (12.8% versus 4.1%, P =0.013), the cumulative MACE rate was not different (23.1% versus 15.9%, P =0.153). Conclusions— The study did not demonstrate a difference in restenosis rate and 6-month clinical outcome between the PTFE-covered stent and the SS stent for treatment of SVG lesions. However, a higher incidence of nonfatal myocardial infarctions was found in patients treated with the PTFE-covered stent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Baim, D. S., Wahr, D., George, B., Leon, M. B., Greenberg, J., Cutlip, D. E., Kaya, U., Popma, J. J., Ho, K. K. L., & Kuntz, R. E. (2002) · Circulation · doi:10.1161/01.cir.0000012783.63093.0c · Cited by 713
Stent Placement Compared with Balloon Angioplasty for Obstructed Coronary Bypass Grafts
Savage, M. P., Douglas, J. S., Fischman, D. L., Pepine, C. J., King, S. B., Werner, J. A., Bailey, S. R., Overlie, P. A., Fenton, S. H., Brinker, J. A., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709113371103 · Cited by 486
Holmes, D. R., Topol, E. J., Califf, R. M., Berdan, L. G., Leya, F., Berger, P. B., Whitlow, P. L., Safian, R. D., Adelman, A. G., Kellett, M. A., et al. (1995) · Circulation · doi:10.1161/01.cir.91.7.1966 · Cited by 201
Weintraub, W. S., Jones, E. L., Graver, J. M., & Guyton, R. A. (1994) · The American Journal of Cardiology · doi:10.1016/0002-9149(94)90198-8 · Cited by 147
Weintraub, W. S., Jones, E. L., Morris, D. C., King, S. B., Guyton, R. A., & Craver, J. M. (1997) · Circulation · doi:10.1161/01.cir.95.4.868 · Cited by 135
Cited by
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
Guidelines for Percutaneous Coronary Interventions
Silber, S., Albertsson, P., Avilés, F. F., Camici, P. G., Colombo, A., Hamm, C., Jørgensen, E., Marco, J., Nordrehaug, J.-E., Ruzyllo, W., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi138 · Cited by 1,609
Self-citation2018 ESC/EACTS Guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · EuroIntervention · doi:10.4244/eijy19m01_01 · Cited by 1,259
2018 ESC/EACTS Guidelines on myocardial revascularization
Sousa-Uva, M., Neumann, F.-J., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezy289 · Cited by 989
Serruys, P. W., Kutryk, M. J. B., & Ong, A. T. L. (2006) · New England Journal of Medicine · doi:10.1056/nejmra051091 · Cited by 762
Harskamp, R. E., Lopes, R. D., Baisden, C. E., de Winter, R. J., & Alexander, J. H. (2013) · Annals of Surgery · doi:10.1097/sla.0b013e318288c38d · Cited by 370
Vermeersch, P., Agostoni, P., Verheye, S., Van den Heuvel, P., Convens, C., Bruining, N., Van den Branden, F., & Van Langenhove, G. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.09.021 · Cited by 256
Self-citationMurphy, E. (2004) · Circulation Research · doi:10.1161/01.res.0000108082.76667.f4 · Cited by 240
Role of stent design and coatings on restenosis and thrombosis
Hara, H., Nakamura, M., Palmaz, J. C., & Schwartz, R. S. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.01.022 · Cited by 177
Metadata
- Authors
- Stankovic, G., Colombo, A., Presbitero, P., van den Branden, F., Inglese, L., Cernigliaro, C., Niccoli, L., Bartorelli, A. L., Rubartelli, P., Reifart, N., Heyndrickx, G. R., Saunamäki, K., Morice, M. C., Sgura, F. A., & Di Mario, C.
- Venue
- Circulation
- Published
- 2003-07-08
- Volume
- 108
- Issue
- 1
- Pages
- 37-42
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2108419122
- Cited by
- 184
- References
- 5
- FWCI
- 11.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.