Ultrasound-Targeted Microbubble Destruction Can Repeatedly Direct Highly Specific Plasmid Expression to the Heart
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Background— Noninvasive, tissue-specific delivery of therapeutic agents would be a valuable clinical tool. We have previously shown that ultrasound-targeted microbubble destruction can direct expression of an adenoviral reporter to the heart. The present study shows that this method can be applied to selectively deliver plasmid vectors to the heart. Methods and Results— We used albumin and lipid microbubbles containing plasmids with a luciferase transgene to target the heart in rats. After 4 days, organs were harvested and analyzed for reporter gene expression. In a second set of experiments, the hearts of rats treated with plasmids were harvested at various time points during a 4-week period. Both luciferase activity and mRNA concentrations were measured. Luciferase transfection with plasmids showed highly specific gene expression in the heart, with hardly any activity in control organs. Time course evaluation showed high transgene expression in the first 4 days, with a rapid decline thereafter. Repeated treatment produced a second peak of transgene expression with similar decay. Conclusions— Ultrasound-mediated destruction of microbubbles directs plasmid transgene expression to the heart with much greater specificity than viral vectors and can be regulated by repeated treatments. This noninvasive technique is a promising method for cardiac gene therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skyba, D. M., Price, R. J., Linka, A. Z., Skalak, T. C., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.98.4.290 · Cited by 474
Echocardiographic Destruction of Albumin Microbubbles Directs Gene Delivery to the Myocardium
Shohet, R. V., Chen, S., Zhou, Y.-T., Wang, Z., Meidell, R. S., Unger, R. H., & Grayburn, P. A. (2000) · Circulation · doi:10.1161/01.cir.101.22.2554 · Cited by 446
Self-citationVincent, K. A., Shyu, K.-G., Luo, Y., Magner, M., Tio, R. A., Jiang, C., Goldberg, M. A., Akita, G. Y., Gregory, R. J., & Isner, J. M. (2000) · Circulation · doi:10.1161/01.cir.102.18.2255 · Cited by 317
Isner, J. M. (2002) · Nature · doi:10.1038/415234a · Cited by 309
Mercadier, J.-J., & Logeart, D. (2002) · PubMed · Cited by 305
Schwarz, E. R., Speakman, M. T., Patterson, M., Hale, S. S., Isner, J. M., Kedes, L. H., & Kloner, R. A. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00522-2 · Cited by 272
Direct in vivo gene transfer into porcine myocardium using replication-deficient adenoviral vectors.
French, B. A., Mazur, W., Geske, R. S., & Bolli, R. (1994) · Circulation · doi:10.1161/01.cir.90.5.2414 · Cited by 241
Wickham, T. J. (2000) · Gene Therapy · doi:10.1038/sj.gt.3301115 · Cited by 236
Reynolds, P. N., Nicklin, S. A., Kaliberova, L., Boatman, B. G., Grizzle, W. E., Balyasnikova, I. V., Baker, A. H., Danilov, S. M., & Curiel, D. T. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-838 · Cited by 225
Chen, S., Shohet, R. V., Bekeredjian, R., Frenkel, P., & Grayburn, P. A. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00627-2 · Cited by 212
Self-citation
Cited by
Ultrasound Microbubble Contrast Agents: Fundamentals and Application to Gene and Drug Delivery
Ferrara, K., Pollard, R., & Borden, M. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095852 · Cited by 1,288
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Ultrasonic drug delivery – a general review
Pitt, W. G., Husseini, G. A., & Staples, B. J. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.37 · Cited by 621
Microbubble compositions, properties and biomedical applications
Sirsi, S. R., & Borden, M. A. (2009) · Bubble Science, Engineering & Technology · doi:10.1179/175889709x446507 · Cited by 594
Gene therapy and DNA delivery systems
Ibraheem, D., Elaissari, A., & Fessi, H. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.11.041 · Cited by 454
Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineering
Qin, S., Caskey, C. F., & Ferrara, K. W. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/6/r01 · Cited by 453
Porter, T. R., Mulvagh, S. L., Abdelmoneim, S. S., Becher, H., Belcik, J. T., Bierig, M., Choy, J., Gaibazzi, N., Gillam, L. D., Janardhanan, R., et al. (2018) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.11.013 · Cited by 432
Klibanov, A. L. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199292.88189.0f · Cited by 424
Microbubbles and ultrasound: from diagnosis to therapy
DIJKMANS, P., JUFFERMANS, L., MUSTERS, R., VANWAMEL, A., TENCATE, F., VANGILST, W., VISSER, C., DEJONG, N., & KAMP, O. (2004) · European Journal of Echocardiography · doi:10.1016/j.euje.2004.02.001 · Cited by 420
Acoustic behavior of microbubbles and implications for drug delivery
Kooiman, K., Vos, H. J., Versluis, M., & de Jong, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.03.003 · Cited by 401
Gene therapy progress and prospects: Ultrasound for gene transfer
Newman, C. M. H., & Bettinger, T. (2007) · Gene Therapy · doi:10.1038/sj.gt.3302925 · Cited by 392
Gene Therapy Progress and Prospects: Electroporation and other physical methods
Wells, D. J. (2004) · Gene Therapy · doi:10.1038/sj.gt.3302337 · Cited by 372
Lipid-Shelled Vehicles: Engineering for Ultrasound Molecular Imaging and Drug Delivery
Ferrara, K. W., Borden, M. A., & Zhang, H. (2009) · Accounts of Chemical Research · doi:10.1021/ar8002442 · Cited by 332
Encapsulated ultrasound microbubbles: Therapeutic application in drug/gene delivery
Liu, Y., Miyoshi, H., & Nakamura, M. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.05.018 · Cited by 319
Boyd, J. H., Kan, B., Roberts, H., Wang, Y., & Walley, K. R. (2008) · Circulation Research · doi:10.1161/circresaha.107.167544 · Cited by 292
Zhang, Y., Huang, X.-R., Wei, L.-H., Chung, A. C., Yu, C.-M., & Lan, H.-Y. (2014) · Molecular Therapy · doi:10.1038/mt.2014.25 · Cited by 271
RetractedIdentification and Characterization of a Novel Adhesin Unique to Oral Fusobacteria
Han, Y. W., Ikegami, A., Rajanna, C., Kawsar, H. I., Zhou, Y., Li, M., Sojar, H. T., Genco, R. J., Kuramitsu, H. K., & Deng, C. X. (2005) · Journal of Bacteriology · doi:10.1128/jb.187.15.5330-5340.2005 · Cited by 259
Use of ultrasound contrast agents for gene or drug delivery in cardiovascular medicine
Bekeredjian, R., Grayburn, P. A., & Shohet, R. V. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.08.067 · Cited by 248
Self-citationPleger, S. T., Shan, C., Ksienzyk, J., Bekeredjian, R., Boekstegers, P., Hinkel, R., Schinkel, S., Leuchs, B., Ludwig, J., Qiu, G., et al. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3002097 · Cited by 234
“Myocardial perfusion echocardiography was used to verify comparability of area at risk during occlusion of the LCX and was performed similar to described protocols (44, 45).”
Self-citationAdvances in Ultrasound Mediated Gene Therapy Using Microbubble Contrast Agents
Sirsi, S. R., & Borden, M. A. (2012) · Theranostics · doi:10.7150/thno.4306 · Cited by 226
“[24] demonstrated that incorporation of plasmid DNA into the MCA shell can result in highly specific targeted organ deposition to the heart.”
BackgroundResultThe use of microbubbles to target drug delivery
Tsutsui, J. M., Xie, F., & Porter, R. T. (2004) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-2-23 · Cited by 215
“Importantly, using the same model the authors confirmed that plasmid transgene expression can be directed to the heart, with an even higher specificity than viral vectors, and that this expression can be regulated by repeated treatments [27].”
Ultrasound-guided drug delivery in cancer
Mullick Chowdhury, S., Lee, T., & Willmann, J. K. (2017) · Ultrasonography · doi:10.14366/usg.17021 · Cited by 210
“Targeted Microbubbles Microbubbles can be molecularly targeted by adding binding ligands onto the shell that allow them to specifically accumulate at certain target area sites [34-41].”
BackgroundEfficient gene delivery to pancreatic islets with ultrasonic microbubble destruction technology
Chen, S., Ding, J.-H., Bekeredjian, R., Yang, B.-Z., Shohet, R. V., Johnston, S. A., Hohmeier, H. E., Newgard, C. B., & Grayburn, P. A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602921103 · Cited by 189
Self-citationMiller, D. L. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.027 · Cited by 172
Sonoporation, drug delivery, and gene therapy
Liang, H.-D., Tang, J., & Halliwell, M. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim565 · Cited by 166
Leong-Poi, H., Kuliszewski, M. A., Lekas, M., Sibbald, M., Teichert-Kuliszewska, K., Klibanov, A. L., Stewart, D. J., & Lindner, J. R. (2007) · Circulation Research · doi:10.1161/circresaha.107.148676 · Cited by 165
Ultrasound-Targeted Microbubble Destruction to Deliver siRNA Cancer Therapy
Carson, A. R., McTiernan, C. F., Lavery, L., Grata, M., Leng, X., Wang, J., Chen, X., & Villanueva, F. S. (2012) · Cancer Research · doi:10.1158/0008-5472.can-11-4079 · Cited by 160
“Delivery of genes that express RNA interference is limited by inefficient DNA transduction, particularly in nonviral systems that do not involve a direct injection into the target site (8-12).”
BackgroundAdvances in Gene Delivery Systems
Kamimura, K., Suda, T., Zhang, G., & Liu, D. (2011) · Pharmaceutical Medicine · doi:10.1007/bf03256872 · Cited by 124
Xia, M., Boini, K. M., Abais, J. M., Xu, M., Zhang, Y., & Li, P.-L. (2014) · The American Journal of Pathology · doi:10.1016/j.ajpath.2014.01.032 · Cited by 106
“Combination of the ultrasound technique and microbubble wrapping for introduction of plasmids greatly enhances transgene expression with a 300-fold increase over naked DNA alone without toxicity.(48,50) The present study by using in vivo molecular imaging demonstrated that plasmids (ASC shRNA plasmids cotransfected wi…”
BackgroundUltrasound targeted CNS gene delivery for Parkinson's disease treatment
Fan, C.-H., Lin, C.-Y., Liu, H.-L., & Yeh, C.-K. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.07.004 · Cited by 97
Cavitation properties of block copolymer stabilized phase-shift nanoemulsions used as drug carriers
Rapoport, N., Christensen, D. A., Kennedy, A. M., & Nam, K.-H. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.11.009 · Cited by 79
Microbubbles as a novel contrast agent for brain MRI
Cheung, J. S., Chow, A. M., Guo, H., & Wu, E. X. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.037 · Cited by 36
“Microbubble-mediated therapy has been used to deliver genes or drugs to specific tissues (Bekeredjian et al., 2003; Hauff et al., 2005; Shimamura et al., 2004; Taniyama et al., 2002) utilizing microbubble cavitation and sonoporation effects, including neural tissues, skeletal muscles, myocardium,…”
Metadata
- Authors
- Bekeredjian, R., Chen, S., Frenkel, P. A., Grayburn, P. A., & Shohet, R. V.
- Venue
- Circulation
- Published
- 2003-08-26
- Volume
- 108
- Issue
- 8
- Pages
- 1022-1026
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2099781987
- Cited by
- 321
- References
- 14
- FWCI
- 15.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.