The DOI matches its Crossref record.
Catheter Ablation for Paroxysmal Atrial Fibrillation: Segmental Pulmonary Vein Ostial Ablation Versus Left Atrial Ablation
Open accessAbstract
Background— Segmental ostial catheter ablation (SOCA) to isolate the pulmonary veins (PVs) and left atrial catheter ablation (LACA) to encircle the PVs both may eliminate paroxysmal atrial fibrillation (PAF). The relative efficacy of these 2 techniques has not been directly compared. Methods and Results— Of 80 consecutive patients with symptomatic PAF (age, 52±10 years), 40 patients underwent PV isolation by SOCA and 40 patients underwent LACA to encircle the PVs. During SOCA, ostial PV potentials recorded with a ring catheter were targeted. LACA was performed by encircling the left- and right-sided PVs 1 to 2 cm from the ostia and was guided by an electroanatomic mapping system; ablation lines also were created in the mitral isthmus and posterior left atrium. The mean procedure and fluoroscopy times were 156±45 and 50±17 minutes for SOCA and 149±33 and 39±12 minutes for LACA, respectively. At 6 months, 67% of patients who underwent SOCA and 88% of patients who underwent LACA were free of symptomatic PAF when not taking antiarrhythmic drug therapy ( P =0.02). Among the variables of age, sex, duration and frequency of PAF, ejection fraction, left atrial size, structural heart disease, and the ablation technique, only an increased left atrial size and the SOCA technique were independent predictors of recurrent PAF. The only complication was left atrial flutter in a patient who underwent LACA. Conclusions— In patients undergoing catheter ablation for PAF, LACA to encircle the PVs is more effective than SOCA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationMarrouche, N. F., Wilber, D., Hindricks, G., Jais, P., Akoum, N., Marchlinski, F., Kholmovski, E., Burgon, N., Hu, N., Mont, L., et al. (2014) · JAMA · doi:10.1001/jama.2014.3 · Cited by 1,473
Metadata
- Authors
- Oral, H., Scharf, C., Chugh, A., Hall, B., Cheung, P., Good, E., Veerareddy, S., Pelosi, F., & Morady, F.
- Venue
- Circulation
- Published
- 2003-11-11
- Volume
- 108
- Issue
- 19
- Pages
- 2355-2360
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2172234567
- Cited by
- 896
- References
- 0
- FWCI
- 60.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Catheter Ablation for Paroxysmal Atrial Fibrillation: Segmental Pulmonary Vein Ostial Ablation Versus Left Atrial Ablation. https://app.cochat.ai/papers/10.1161/01.cir.0000095796.45180.88
- The paper
- Oral, H., Scharf, C., Chugh, A., Hall, B., Cheung, P., Good, E., Veerareddy, S., Pelosi, F., & Morady, F. (2003). Catheter Ablation for Paroxysmal Atrial Fibrillation: Segmental Pulmonary Vein Ostial Ablation Versus Left Atrial Ablation. Circulation. https://doi.org/10.1161/01.cir.0000095796.45180.88
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.