Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Randomized Study Comparing Combined Pulmonary Vein–Left Atrial Junction Disconnection and Cavotricuspid Isthmus Ablation Versus Pulmonary Vein–Left Atrial Junction Disconnection Alone in Patients Presenting With Typical Atrial Flutter and Atrial Fibrillation

Wazni, Oussama, Marrouche, Nassir F., Martin, David O., Gillinov, A. Marc, Saliba, Walid, Saad, Eduardo, Klein, Allan, Bhargava, Mandeep, Bash, Dianna, Schweikert, Robert, Erciyes, Demet, Abdul-Karim, Ahmad, Brachman, Johannes, Gunther, Jens, Pisano, Ennio, Potenza, Domenico, Fanelli, Raffaele, Natale, Andrea · 2003 · Circulation

Abstract

Background— Atrial flutter (AFL) and atrial fibrillation (AF) frequently coexist in the same patient. Recently it has been demonstrated that the triggers for both AF and AFL may originate in the pulmonary veins (PVs). We hypothesized that in patients with both AF and typical AFL, pulmonary vein–left atrial junction (PV-LAJ) disconnection may eliminate both arrhythmias. Methods and Results— Consecutive patients with documented symptomatic AF and typical AFL were randomly assigned to have PV-LAJ disconnection combined with cavotricuspid isthmus (CTI) ablation (group 1, n=49) or PV-LAJ disconnection alone (group 2, n=59). Within the first 8 weeks after ablation, 32 of the group 2 patients had typical AFL documented, whereas none was seen in group 1. Twenty of these 32 converted to sinus rhythm after initiating antiarrhythmic drugs (AADs). Twelve were cardioverted, and AADs were started. After 8 weeks, all AADS were stopped, and only 3 patients continued to have recurrent sustained typical AFL that was eliminated by CTI ablation. Beyond 8 weeks of follow-up, 7 patients in group 1 and 6 patients in group 2 (14% and 11%, respectively) continued to have AF. Ten of these 13 patients underwent a repeat PV-LAJ disconnection procedure and were cured. The remaining 3 remained in normal sinus rhythm while taking AADs. Conclusions— In patients with both AFL and AF, PV-LAJ disconnection alone may be sufficient to control both arrhythmias. CTI block reduced early postablation recurrence of arrhythmias, which in the majority of patients reflects a short-term clinical problem.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000101684.88679.ab

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 179

Metadata

Authors
Wazni, O., Marrouche, N. F., Martin, D. O., Gillinov, A. M., Saliba, W., Saad, E., Klein, A., Bhargava, M., Bash, D., Schweikert, R., Erciyes, D., Abdul-Karim, A., Brachman, J., Gunther, J., Pisano, E., Potenza, D., Fanelli, R., & Natale, A.
Venue
Circulation
Published
2003-11-18
Volume
108
Issue
20
Pages
2479-2483
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2162381829
Cited by
179
References
2
FWCI
2.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomized Study Comparing Combined Pulmonary Vein–Left Atrial Junction Disconnection and Cavotricuspid Isthmus Ablation Versus Pulmonary Vein–Left Atrial Junction Disconnection Alone in Patients Presenting With Typical Atrial Flutter and Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/01.cir.0000101684.88679.ab
The paper
Wazni, O., Marrouche, N. F., Martin, D. O., Gillinov, A. M., Saliba, W., Saad, E., Klein, A., Bhargava, M., Bash, D., Schweikert, R., Erciyes, D., Abdul-Karim, A., Brachman, J., Gunther, J., Pisano, E., Potenza, D., Fanelli, R., & Natale, A. (2003). Randomized Study Comparing Combined Pulmonary Vein–Left Atrial Junction Disconnection and Cavotricuspid Isthmus Ablation Versus Pulmonary Vein–Left Atrial Junction Disconnection Alone in Patients Presenting With Typical Atrial Flutter and Atrial Fibrillation. Circulation. https://doi.org/10.1161/01.cir.0000101684.88679.ab

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.