The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Successful Catheter Ablation of Electrical Storm After Myocardial Infarction
Open accessAbstract
Background— We report on 4 patients (aged 57 to 77 years; 3 men) who developed drug-refractory, repetitive ventricular tachyarrhythmias after acute myocardial infarction (MI). All episodes of ventricular arrhythmias were triggered by monomorphic ventricular premature beats (VPBs) with a right bundle-branch block morphology (RBBB). Methods and Results— Left ventricular (LV) mapping was performed to attempt radiofrequency (RF) ablation of the triggering VPBs. Activation mapping of the clinical VPBs demonstrated the earliest activation in the anteromedial LV in 1 patient and in the inferomedial LV in 2 patients. Short, high-frequency, low-amplitude potentials were recorded that preceded the onset of each extrasystole by a maximum of 126 to 160 ms. At the same site, a Purkinje potential was documented that preceded the onset of the QRS complex by 23 to 26 ms during sinus rhythm. In 1 patient, only pace mapping was attempted to identify areas of interest in the LV. Six to 30 RF applications abolished all local Purkinje potentials at the site of earliest activation and/or perfect pace mapping and suppressed VPBs in all patients. No episode of ventricular tachycardia or fibrillation has recurred for 33, 14, 6, and 5 months in patients 1, 2, 3, and 4, respectively. Conclusions— Incessant ventricular tachyarrhythmias after MI may be triggered by VPBs. RF ablation of the triggering VPBs is feasible and can prevent drug-resistant electrical storm, even after acute MI. Catheter ablation of the triggering VPBs may be used as a bailout therapy in these patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mapping and Ablation of Idiopathic Ventricular Fibrillation
Haïssaguerre, M., Shoda, M., Jaïs, P., Nogami, A., Shah, D. C., Kautzner, J., Arentz, T., Kalushe, D., Lamaison, D., Griffith, M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000027564.55739.b1 · Cited by 686
Self-citationJanse, M. J., van Capelle, F. J., Morsink, H., Kléber, A. G., Wilms-Schopman, F., Cardinal, R., d'Alnoncourt, C. N., & Durrer, D. (1980) · Circulation Research · doi:10.1161/01.res.47.2.151 · Cited by 605
Treating Electrical Storm: Sympathetic Blockade Versus Advanced Cardiac Life Support–Guided Therapy
Nademanee, K., Taylor, R., Bailey, W. E., Rieders, D. E., & Kosar, E. M. (2000) · Circulation · doi:10.1161/01.cir.102.7.742 · Cited by 504
Kawara, T., Derksen, R., de Groot, J. R., Coronel, R., Tasseron, S., Linnenbank, A. C., Hauer, R. N. W., Kirkels, H., Janse, M. J., & de Bakker, J. M. T. (2001) · Circulation · doi:10.1161/hc5001.100833 · Cited by 390
Role of Purkinje conducting system in triggering of idiopathic ventricular fibrillation
Haïssaguerre, M., Shah, D. C., Jaïs, P., Shoda, M., Kautzner, J., Arentz, T., Kalushe, D., Kadish, A., Griffith, M., Gaïta, F., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07807-8 · Cited by 380
Self-citationMaggioni, A. P., Zuanetti, G., Franzosi, M. G., Rovelli, F., Santoro, E., Staszewsky, L., Tavazzi, L., & Tognoni, G. (1993) · Circulation · doi:10.1161/01.cir.87.2.312 · Cited by 367
Janse, M. J., & Kléber, A. G. (1981) · Circulation Research · doi:10.1161/01.res.49.5.1069 · Cited by 318
Somberg, J. C., Bailin, S. J., Haffajee, C. I., Paladino, W. P., Kerin, N. Z., Bridges, D., Timar, S., & Molnar, J. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02707-8 · Cited by 176
Molina‐Viamonte, V., Anyukhovsky, E. P., & Rosen, M. R. (1991) · Circulation · doi:10.1161/01.cir.84.4.1732 · Cited by 65
An overview of the management of electrical storm.
Dorian, P., & Cass, D. (1997) · PubMed · Cited by 62
Cited by
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Myerburg, R. J., Quinones, M. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.010 · Cited by 1,973
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Writing Committee Members, Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., et al. (2006) · Europace · doi:10.1093/europace/eul108 · Cited by 738
Metadata
- Authors
- Bänsch, D., Oyang, F., Antz, M., Arentz, T., Weber, R., Val-Mejias, J. E., Ernst, S., & Kuck, K.-H.
- Venue
- Circulation
- Published
- 2003-12-16
- Volume
- 108
- Issue
- 24
- Pages
- 3011-3016
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2126806507
- Cited by
- 307
- References
- 13
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Successful Catheter Ablation of Electrical Storm After Myocardial Infarction. https://app.cochat.ai/papers/10.1161/01.cir.0000103701.30662.5c
- The paper
- Bänsch, D., Oyang, F., Antz, M., Arentz, T., Weber, R., Val-Mejias, J. E., Ernst, S., & Kuck, K.-H. (2003). Successful Catheter Ablation of Electrical Storm After Myocardial Infarction. Circulation. https://doi.org/10.1161/01.cir.0000103701.30662.5c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.