Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 193

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Clinical and Angiographic Predictors of Restenosis After Stent Deployment in Diabetic Patients

Open access
West, Nick E.J., Ruygrok, Peter N., Disco, Clemens M.C., Webster, Mark W.I., Lindeboom, Wietze K., O’Neill, William W., Mercado, Nestor F., Serruys, Patrick W. · 2004 · Circulation

Abstract

Background— Restenosis and consequent adverse cardiac events are increased in diabetics undergoing percutaneous coronary intervention. Use of intracoronary stents may ameliorate such risks; however, factors influencing the likelihood of restenosis after stent deployment in this high-risk patient subgroup are unknown. Methods and Results— We retrospectively analyzed all stented diabetic patients in 16 studies of percutaneous coronary intervention, all of which underwent core angiographic analysis at Cardialysis, Rotterdam. Univariate and multivariate analyses, with 37 clinical and angiographic variables, compared those with and without restenosis and predicted restenosis rates calculated through the use of reference charts derived from angiographic data. Within the studies, 418 of 3090 (14%) stented patients with 6-month angiographic follow-up had diabetes. Restenosis (≥50% diameter stenosis at follow-up) occurred in 550 of 2672 (20.6%) nondiabetic and 130 of 418 (31.1%) diabetic patients ( P <0.001). Univariate predictors of restenosis in diabetics were smaller vessel reference diameter (RD) ( P <0.001), smaller minimal luminal diameter before stenting ( P =0.01), smaller minimal luminal diameter and percent diameter stenosis after stenting ( P <0.001, P =0.04), greater stented length of vessel ( P <0.001), and reduced body mass index (BMI) ( P =0.04). With the use of multivariate analysis, only smaller RD ( P =0.003), greater stented length of vessel ( P =0.04), and reduced BMI ( P =0.04) were associated with restenosis. Reference charts demonstrated an incremental risk of restenosis that appears solely dependent on vessel RD. Conclusions— Restenosis after stent deployment is significantly increased in diabetic patients. Vessel caliber, stented length of vessel, and lower BMI are predictors of in-stent restenosis in patients with diabetes. Furthermore, vessel caliber affected the predicted risk of restenosis incrementally.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000116750.63158.94

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 193

Metadata

Authors
West, N. E. J., Ruygrok, P. N., Disco, C. M. C., Webster, M. W. I., Lindeboom, W. K., O’Neill, W. W., Mercado, N. F., & Serruys, P. W.
Venue
Circulation
Published
2004-02-24
Volume
109
Issue
7
Pages
867-873
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2019864608
Cited by
193
References
1
FWCI
16.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical and Angiographic Predictors of Restenosis After Stent Deployment in Diabetic Patients. https://app.cochat.ai/papers/10.1161/01.cir.0000116750.63158.94
The paper
West, N. E. J., Ruygrok, P. N., Disco, C. M. C., Webster, M. W. I., Lindeboom, W. K., O’Neill, W. W., Mercado, N. F., & Serruys, P. W. (2004). Clinical and Angiographic Predictors of Restenosis After Stent Deployment in Diabetic Patients. Circulation. https://doi.org/10.1161/01.cir.0000116750.63158.94

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.