CoChat

Left Cardiac Sympathetic Denervation in the Management of High-Risk Patients Affected by the Long-QT Syndrome

Open access
Schwartz, Peter J., Priori, Silvia G., Cerrone, Marina, Spazzolini, Carla, Odero, Attilio, Napolitano, Carlo, Bloise, Raffaella, De Ferrari, Gaetano M., Klersy, Catherine, Moss, Arthur J., Zareba, Wojciech, Robinson, Jennifer L., Hall, W. Jackson, Brink, Paul A., Toivonen, Lauri, Epstein, Andrew E., Li, Cuilan, Hu, Dayi · 2004 · Circulation
Cited by 686

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Background— The management of long-QT syndrome (LQTS) patients who continue to have cardiac events (CEs) despite β-blockers is complex. We assessed the long-term efficacy of left cardiac sympathetic denervation (LCSD) in a group of high-risk patients. Methods and Results— We identified 147 LQTS patients who underwent LCSD. Their QT interval was very prolonged (QTc, 543±65 ms); 99% were symptomatic; 48% had a cardiac arrest; and 75% of those treated with β-blockers remained symptomatic. The average follow-up periods between first CE and LCSD and post-LCSD were 4.6 and 7.8 years, respectively. After LCSD, 46% remained asymptomatic. Syncope occurred in 31%, aborted cardiac arrest in 16%, and sudden death in 7%. The mean yearly number of CEs per patient dropped by 91% ( P <0.001). Among 74 patients with only syncope before LCSD, all types of CEs decreased significantly as in the entire group, and a post-LCSD QTc <500 ms predicted very low risk. The percentage of patients with >5 CEs declined from 55% to 8% ( P <0.001). In 5 patients with preoperative implantable defibrillator and multiple discharges, the post-LCSD count of shocks decreased by 95% ( P =0.02) from a median number of 25 to 0 per patient. Among 51 genotyped patients, LCSD appeared more effective in LQT1 and LQT3 patients. Conclusions— LCSD is associated with a significant reduction in the incidence of aborted cardiac arrest and syncope in high-risk LQTS patients when compared with pre-LCSD events. However, LCSD is not entirely effective in preventing cardiac events including sudden cardiac death during long-term follow-up. LCSD should be considered in patients with recurrent syncope despite β-blockade and in patients who experience arrhythmia storms with an implanted defibrillator.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000125523.14403.1e

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 686

Metadata

Authors
Schwartz, P. J., Priori, S. G., Cerrone, M., Spazzolini, C., Odero, A., Napolitano, C., Bloise, R., De Ferrari, G. M., Klersy, C., Moss, A. J., Zareba, W., Robinson, J. L., Hall, W. J., Brink, P. A., Toivonen, L., Epstein, A. E., Li, C., & Hu, D.
Venue
Circulation
Published
2004-04-20
Volume
109
Issue
15
Pages
1826-1833
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2133663070
Cited by
686
References
24
FWCI
14.46
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.