CoChat

Sensitivity and Specificity of Prenatal Features of Physiological Shunts to Predict Neonatal Clinical Status in Transposition of the Great Arteries

Jouannic, Jean-Marie, Gavard, Laurent, Fermont, Laurent, Le Bidois, Jérôme, Parat, Sophie, Vouhé, Pascal R., Dumez, Yves, Sidi, Daniel, Bonnet, Damien · 2004 · Circulation
Cited by 154

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background— Although prenatal diagnosis of transposition of the great arteries (TGA) reduces neonatal mortality, the preoperative course can be complicated in infants with a restrictive foramen ovale (FO) or a ductus arteriosus (DA) constriction. We sought to determine the specificity and sensitivity of prenatal features of physiological shunts in predicting postnatal clinical status in prenatally diagnosed TGA in babies delivered in a tertiary care center providing all facilities for neonatal urgent care. Methods and Results— The outcomes of 130 fetuses with TGA were reviewed over a period of 5.5 years. Restriction of the FO and/or constriction of the DA could be analyzed in 119/130 fetuses at 36±2.7 weeks of gestation. Twenty-four out of 119 had at least 1 abnormal shunt (23 FO, 5 DA, and 4 both). Thirteen of 130 neonates had profound hypoxemia (PaO 2 <25 mm Hg) and metabolic acidosis (pH <7.15) in the first 30 minutes and required immediate balloon atrioseptostomy. Two who had abnormal FO and DA died despite aggressive resuscitation. The specificity and sensitivity of the fetal echo in predicting neonatal emergency were 84% and 54%, respectively. The specificity and sensitivity of a combination of restrictive FO and DA constriction were 100% and 31%, respectively. Conclusions— Restriction of the FO and/or of the DA has a high specificity to predict the need for emergency neonatal care in fetuses with TGA, but the sensitivity is too low to detect all high-risk fetuses. Exceptional procedures should be considered for fetuses that have a combination of restrictive FO and DA constriction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000144141.18560.cf

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 154

Metadata

Authors
Jouannic, J.-M., Gavard, L., Fermont, L., Le Bidois, J., Parat, S., Vouhé, P. R., Dumez, Y., Sidi, D., & Bonnet, D.
Venue
Circulation
Published
2004-09-28
Volume
110
Issue
13
Pages
1743-1746
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2073635019
Cited by
154
References
1
FWCI
1.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitivity and Specificity of Prenatal Features of Physiological Shunts to Predict Neonatal Clinical Status in Transposition of the Great Arteries. https://app.cochat.ai/papers/10.1161/01.cir.0000144141.18560.cf
The paper
Jouannic, J.-M., Gavard, L., Fermont, L., Le Bidois, J., Parat, S., Vouhé, P. R., Dumez, Y., Sidi, D., & Bonnet, D. (2004). Sensitivity and Specificity of Prenatal Features of Physiological Shunts to Predict Neonatal Clinical Status in Transposition of the Great Arteries. Circulation. https://doi.org/10.1161/01.cir.0000144141.18560.cf

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.