The DOI matches its Crossref record.
Predictive Value of 16-Slice Multidetector Spiral Computed Tomography to Detect Significant Obstructive Coronary Artery Disease in Patients at High Risk for Coronary Artery Disease: Patient- Versus Segment-Based Analysis
Abstract
Background— In this study, we investigated the diagnostic value and limitations of multidetector computed tomography (MDCT)–based noninvasive detection of significant obstructive coronary artery disease (CAD) in a consecutive high-risk patient population with inclusion of all coronary segments. Methods and Results— In a prospective, blinded, standard cross-sectional technology assessment, a cohort of 33 consecutive patients with a positive stress test result underwent 16-slice MDCT and selective coronary angiography for the detection of significant obstructive CAD. We assessed the diagnostic accuracy of MDCT in a segment-based and a patient-based model and determined the impact of stenosis location and the presence of calcification on diagnostic accuracy in both models. Analysis of all 530 coronary segments demonstrated moderate sensitivity (63%) and excellent specificity (96%) with a moderate positive predictive value of 64% and an excellent negative predictive value (NPV) of 96% for the detection of significant coronary stenoses. Assessment restricted to either proximal coronary segments or segments with excellent image quality (83% of all segments) led to an increase in sensitivity (70% and 82%, respectively), and high specificities were maintained (94% and 93%, respectively). In a patient-based model, the NPV of MDCT for significant CAD was limited to 75%. Coronary calcification was the major cause of false-positive findings (94%). Conclusions— For all coronary segments included, 16-slice MDCT has moderate diagnostic value for the detection of significant obstructive coronary artery stenosis in a population with a high prevalence of CAD. The moderate NPV of patient-based detection of CAD suggests a limited impact on clinical decision-making in high-risk populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hoffmann, U., Moselewski, F., Nieman, K., Jang, I.-K., Ferencik, M., Rahman, A. M., Cury, R. C., Abbara, S., Joneidi-Jafari, H., Achenbach, S., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.041 · Cited by 566
Self-citationSchroeder, S., Achenbach, S., Bengel, F., Burgstahler, C., Cademartiri, F., de Feyter, P., George, R., Kaufmann, P., Kopp, A. F., Knuuti, J., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm544 · Cited by 554
Self-citationNoninvasive detection of macrophages using a nanoparticulate contrast agent for computed tomography
Hyafil, F., Cornily, J.-C., Feig, J. E., Gordon, R., Vucic, E., Amirbekian, V., Fisher, E. A., Fuster, V., Feldman, L. J., & Fayad, Z. A. (2007) · Nature Medicine · doi:10.1038/nm1571 · Cited by 467
Pohle, K., Achenbach, S., MacNeill, B., Ropers, D., Ferencik, M., Moselewski, F., Hoffmann, U., Brady, T. J., Jang, I.-K., & Daniel, W. G. (2007) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2006.01.013 · Cited by 289
Self-citation
Metadata
- Authors
- Hoffmann, U., Moselewski, F., Cury, R. C., Ferencik, M., Jang, I.-K., Diaz, L. J., Abbara, S., Brady, T. J., & Achenbach, S.
- Venue
- Circulation
- Published
- 2004-10-26
- Volume
- 110
- Issue
- 17
- Pages
- 2638-2643
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2149964306
- Cited by
- 413
- References
- 0
- FWCI
- 51.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Predictive Value of 16-Slice Multidetector Spiral Computed Tomography to Detect Significant Obstructive Coronary Artery Disease in Patients at High Risk for Coronary Artery Disease: Patient- Versus Segment-Based Analysis. https://app.cochat.ai/papers/10.1161/01.cir.0000145614.07427.9f
- The paper
- Hoffmann, U., Moselewski, F., Cury, R. C., Ferencik, M., Jang, I.-K., Diaz, L. J., Abbara, S., Brady, T. J., & Achenbach, S. (2004). Predictive Value of 16-Slice Multidetector Spiral Computed Tomography to Detect Significant Obstructive Coronary Artery Disease in Patients at High Risk for Coronary Artery Disease: Patient- Versus Segment-Based Analysis. Circulation. https://doi.org/10.1161/01.cir.0000145614.07427.9f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.