Predictive Value of 16-Slice Multidetector Spiral Computed Tomography to Detect Significant Obstructive Coronary Artery Disease in Patients at High Risk for Coronary Artery Disease: Patient- Versus Segment-Based Analysis
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background— In this study, we investigated the diagnostic value and limitations of multidetector computed tomography (MDCT)–based noninvasive detection of significant obstructive coronary artery disease (CAD) in a consecutive high-risk patient population with inclusion of all coronary segments. Methods and Results— In a prospective, blinded, standard cross-sectional technology assessment, a cohort of 33 consecutive patients with a positive stress test result underwent 16-slice MDCT and selective coronary angiography for the detection of significant obstructive CAD. We assessed the diagnostic accuracy of MDCT in a segment-based and a patient-based model and determined the impact of stenosis location and the presence of calcification on diagnostic accuracy in both models. Analysis of all 530 coronary segments demonstrated moderate sensitivity (63%) and excellent specificity (96%) with a moderate positive predictive value of 64% and an excellent negative predictive value (NPV) of 96% for the detection of significant coronary stenoses. Assessment restricted to either proximal coronary segments or segments with excellent image quality (83% of all segments) led to an increase in sensitivity (70% and 82%, respectively), and high specificities were maintained (94% and 93%, respectively). In a patient-based model, the NPV of MDCT for significant CAD was limited to 75%. Coronary calcification was the major cause of false-positive findings (94%). Conclusions— For all coronary segments included, 16-slice MDCT has moderate diagnostic value for the detection of significant obstructive coronary artery stenosis in a population with a high prevalence of CAD. The moderate NPV of patient-based detection of CAD suggests a limited impact on clinical decision-making in high-risk populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nieman, K., Cademartiri, F., Lemos, P. A., Raaijmakers, R., Pattynama, P. M. T., & de Feyter, P. J. (2002) · Circulation · doi:10.1161/01.cir.0000037222.58317.3d · Cited by 956
Ropers, D., Baum, U., Pohle, K., Anders, K., Ulzheimer, S., Ohnesorge, B., Schlundt, C., Bautz, W., Daniel, W. G., & Achenbach, S. (2003) · Circulation · doi:10.1161/01.cir.0000055738.31551.a9 · Cited by 930
Self-citationCoronary angiography with multi-slice computed tomography
Nieman, K., Oudkerk, M., Rensing, B. J., van Ooijen, P., Munne, A., van Geuns, R.-J., & de Feyter, P. J. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04058-7 · Cited by 725
Achenbach, S., Giesler, T., Ropers, D., Ulzheimer, S., Derlien, H., Schulte, C., Wenkel, E., Moshage, W., Bautz, W., Daniel, W. G., et al. (2001) · Circulation · doi:10.1161/01.cir.103.21.2535 · Cited by 667
Self-citationOhnesorge, B., Flohr, T., Becker, C., Kopp, A. F., Schoepf, U. J., Baum, U., Knez, A., Klingenbeck-Regn, K., & Reiser, M. F. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv30564 · Cited by 516
Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CT
Achenbach, S., Ulzheimer, S., Baum, U., Kachelrieß, M., Ropers, D., Giesler, T., Bautz, W., Daniel, W. G., Kalender, W. A., & Moshage, W. (2000) · Circulation · doi:10.1161/01.cir.102.23.2823 · Cited by 434
Self-citationKopp, A. (2002) · European Heart Journal · doi:10.1016/s0195-668x(02)93264-1 · Cited by 252
Flohr, T., Bruder, H., Stierstorfer, K., Simon, J., Schaller, S., & Ohnesorge, B. (2002) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2002-32930 · Cited by 164
Leber, A. W., Knez, A., Becker, C. R., Becker, A., White, C. W., Thilo, C., Reiser, M. F., Haberl, R., & Steinbeck, G. (2003) · Heart · doi:10.1136/heart.89.6.633 · Cited by 87
Cited by
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Self-citationQuantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Hoffmann, U., Moselewski, F., Nieman, K., Jang, I.-K., Ferencik, M., Rahman, A. M., Cury, R. C., Abbara, S., Joneidi-Jafari, H., Achenbach, S., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.041 · Cited by 566
Self-citationSchroeder, S., Achenbach, S., Bengel, F., Burgstahler, C., Cademartiri, F., de Feyter, P., George, R., Kaufmann, P., Kopp, A. F., Knuuti, J., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm544 · Cited by 554
Self-citation
Metadata
- Authors
- Hoffmann, U., Moselewski, F., Cury, R. C., Ferencik, M., Jang, I.-K., Diaz, L. J., Abbara, S., Brady, T. J., & Achenbach, S.
- Venue
- Circulation
- Published
- 2004-10-26
- Volume
- 110
- Issue
- 17
- Pages
- 2638-2643
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2149964306
- Cited by
- 413
- References
- 9
- FWCI
- 51.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.