CoChat

Firing Properties of Single Muscle Vasoconstrictor Neurons in the Sympathoexcitation Associated With Congestive Heart Failure

Open access
Macefield, Vaughan G., Rundqvist, Bengt, Sverrisdottir, Yrsa B., Wallin, B. Gunnar, Elam, Mikael · 1999 · Circulation
Cited by 96

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background —Congestive heart failure (CHF) in humans is associated with a marked sympathoexcitation, including an augmented muscle sympathetic nerve activity (MSNA) in intraneural multiunit recordings. In the present study, single-unit recording was used to evaluate whether the firing properties of individual muscle vasoconstrictor neurons can reveal underlying mechanisms for this increase in MSNA. Methods and Results —Eight patients with CHF (NYHA class II to IV; left ventricular ejection fraction, 29±5%, mean±SEM) were studied. In standard multiunit recordings, MSNA burst incidence (bursts/100 heartbeats) ranged from 65% to 100% (88±5%). Using selective tungsten microelectrodes, we made recordings from 16 single muscle vasoconstrictor axons. Mean unit firing probability (ie, the percentage of cardiac intervals in which a single axon fired) was 54.5±5.2% (range, 21 to 89%), and mean firing frequency was 0.98±0.22 Hz (0.14 to 3.86 Hz), both of which were higher than seen previously in healthy subjects ( P <0.001). Although single neurons occasionally generated multiple spikes per sympathetic burst, such multiple firing was rare and was not different from that seen in healthy subjects. Conclusions —An increased firing frequency of individual vasoconstrictor neurons is one mechanism for the increased number of multiunit MSNA bursts at rest in CHF. The neurons discharge in more diastoles than in healthy subjects (ie, firing probability is increased), but the likelihood of discharging >1 impulse per sympathetic burst is not increased. Despite the intense multiunit activity at rest, the firing characteristics of individual vasoconstrictor axons indicate a remaining capacity for transient increases of MSNA in CHF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.100.16.1708

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 96

Metadata

Authors
Macefield, V. G., Rundqvist, B., Sverrisdottir, Y. B., Wallin, B. G., & Elam, M.
Venue
Circulation
Published
1999-10-19
Volume
100
Issue
16
Pages
1708-1713
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2097858723
Cited by
96
References
3
FWCI
1.81
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Firing Properties of Single Muscle Vasoconstrictor Neurons in the Sympathoexcitation Associated With Congestive Heart Failure. https://app.cochat.ai/papers/10.1161/01.cir.100.16.1708
The paper
Macefield, V. G., Rundqvist, B., Sverrisdottir, Y. B., Wallin, B. G., & Elam, M. (1999). Firing Properties of Single Muscle Vasoconstrictor Neurons in the Sympathoexcitation Associated With Congestive Heart Failure. Circulation. https://doi.org/10.1161/01.cir.100.16.1708

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.