The DOI matches its Crossref record.
Relationship of MRI Delayed Contrast Enhancement to Irreversible Injury, Infarct Age, and Contractile Function
Abstract
Background —Contrast MRI enhancement patterns in several pathophysiologies resulting from ischemic myocardial injury are controversial or have not been investigated. We compared contrast enhancement in acute infarction (AI), after severe but reversible ischemic injury (RII), and in chronic infarction. Methods and Results —In dogs, a large coronary artery was occluded to study AI and/or chronic infarction (n=18), and a second coronary artery was chronically instrumented with a reversible hydraulic occluder and Doppler flowmeter to study RII (n=8). At 3 days after surgery, cine MRI revealed reduced wall thickening in AI (5±6% versus 33±6% in normal, P <0.001). In RII, wall thickening before, during, and after inflation of the occluder for 15 minutes was 35±5%, 1±8%, and 21±10% and Doppler flow was 19.8±5.3, 0.2±0.5, and 56.3±17.7 (peak hyperemia) cm/s, respectively, confirming occlusion, transient ischemia, and reperfusion. Gd-DTPA–enhanced MR images acquired 30 minutes after contrast revealed hyperenhancement of AI (294±96% of normal, P <0.001) but not of RII (98±6% of normal, P =NS). Eight weeks later, the chronically infarcted region again hyperenhanced (253±54% of normal, n=8, P <0.001). High-resolution (0.5×0.5×0.5 mm) ex vivo MRI demonstrated that the spatial extent of hyperenhancement was the same as the spatial extent of myocyte necrosis with and without reperfusion at 1 day ( R =0.99, P <0.001) and 3 days ( R =0.99, P <0.001) and collagenous scar at 8 weeks ( R =0.97, P <0.001). Conclusions —In the pathophysiologies investigated, contrast MRI distinguishes between reversible and irreversible ischemic injury independent of wall motion and infarct age.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Marrouche, N. F., Wilber, D., Hindricks, G., Jais, P., Akoum, N., Marchlinski, F., Kholmovski, E., Burgon, N., Hu, N., Mont, L., et al. (2014) · JAMA · doi:10.1001/jama.2014.3 · Cited by 1,473
Bleeker, G. B., Kaandorp, T. A. M., Lamb, H. J., Boersma, E., Steendijk, P., de Roos, A., van der Wall, E. E., Schalij, M. J., & Bax, J. J. (2006) · Circulation · doi:10.1161/circulationaha.105.543678 · Cited by 760
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Ezekowitz, J. A., O'Meara, E., McDonald, M. A., Abrams, H., Chan, M., Ducharme, A., Giannetti, N., Grzeslo, A., Hamilton, P. G., Heckman, G. A., et al. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.08.022 · Cited by 676
Metadata
- Authors
- Kim, R. J., Fieno, D. S., Parrish, T. B., Harris, K., Chen, E.-L., Simonetti, O., Bundy, J., Finn, J. P., Klocke, F. J., & Judd, R. M.
- Venue
- Circulation
- Published
- 1999-11-09
- Volume
- 100
- Issue
- 19
- Pages
- 1992-2002
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2161947705
- Cited by
- 2,581
- References
- 0
- FWCI
- 20.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationship of MRI Delayed Contrast Enhancement to Irreversible Injury, Infarct Age, and Contractile Function. https://app.cochat.ai/papers/10.1161/01.cir.100.19.1992
- The paper
- Kim, R. J., Fieno, D. S., Parrish, T. B., Harris, K., Chen, E.-L., Simonetti, O., Bundy, J., Finn, J. P., Klocke, F. J., & Judd, R. M. (1999). Relationship of MRI Delayed Contrast Enhancement to Irreversible Injury, Infarct Age, and Contractile Function. Circulation. https://doi.org/10.1161/01.cir.100.19.1992
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.