Deformational Dynamics of the Aortic Root : Modes and Physiologic Determinants
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Current surgical methods for treating aortic valve and aortic root pathology vary widely, and the basis for selecting one repair or replacement alternative over another continues to evolve. More precise knowledge of the interaction between normal aortic root dynamics and aortic valve mechanics may clarify the implications of various surgical procedures on long-term valve function and durability. METHODS AND RESULTS: To investigate the role of aortic root dynamics on valve function, we studied the deformation modes of the left, right, and noncoronary aortic root regions during isovolumic contraction, ejection, isovolumic relaxation, and diastole. Radiopaque markers were implanted at the top of the 3 commissures (sinotubular ridge) and at the annular base of the 3 sinuses in 6 adult sheep. After a 1-week recovery, ECG and left ventricular and aortic pressures were recorded in conscious, sedated animals, and the 3D marker coordinates were computed from biplane videofluorograms (60 Hz). Left ventricular preload, contractility, and afterload were independently manipulated to assess the effects of changing hemodynamics on aortic root 3D dynamic deformation. The ovine aortic root undergoes complex, asymmetric deformations during the various phases of the cardiac cycle, including aortoventricular and sinotubular junction strain and aortic root elongation, compression, shear, and torsional deformation. These deformations were not homogeneous among the left, right, and noncoronary regions. Furthermore, changes in left ventricular volume, pressure, and contractility affected the degree of deformation in a nonuniform manner in the 3 regions studied, and these effects varied during isovolumic contraction, ejection, isovolumic relaxation, and diastole. CONCLUSIONS: These complex 3D aortic root deformations probably minimize aortic cusp stresses by creating optimal cusp loading conditions and minimizing transvalvular turbulence. Aortic valve repair techniques or methods of replacement using unstented autograft, allograft, or xenograft tissue valves that best preserve this normal pattern of aortic root dynamics should translate into a lower risk of long-term cusp deterioration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
Guidelines for reporting morbidity and mortality after cardiac valvular operations
Edmunds, L. H., Clark, R. E., Cohn, L. H., Grunkemeier, G. L., Miller, D. C., & Weisel, R. D. (1996) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(96)70055-7 · Cited by 1,000 · cited 1×
“Data were then acquired after (1) inotropic augmentation (calcium chloride 1 g IV bolus); (2) a 30% increase in LV afterload (aortic systolic pressure) with phenylephrine; and (3) a 30% decrease in LV afterload with sodium nitroprusside.”
MethodSelf-citationWaldman, L. K., Fung, Y. C., & Covell, J. W. (1985) · Circulation Research · doi:10.1161/01.res.57.1.152 · Cited by 363
Dimensions and Geometric Relationships of the Human Aortic Value as a Function of Pressure
SWANSON, W. M., & CLARK, R. E. (1974) · Circulation Research · doi:10.1161/01.res.35.6.871 · Cited by 350
Brewer, R. J., Deck, J. D., Capati, B., et al. (1976) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)40069-x · Cited by 182
Lund, O., Chandrasekaran, V., Grocott-Mason, R., Elwidaa, H., Mazhar, R., Khaghani, A., Mitchell, A., Ilsley, C., & Yacoub, M. H. (1999) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(99)70471-x · Cited by 175 · cited 1×
“Data were then acquired after (1) inotropic augmentation (calcium chloride 1 g IV bolus); (2) a 30% increase in LV afterload (aortic systolic pressure) with phenylephrine; and (3) a 30% decrease in LV afterload with sodium nitroprusside.”
MethodThe mechanism of opening of the aortic valve
Thubrikar, M. J., Bosher, L. P., & Nolan, S. P. (1979) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)38191-7 · Cited by 146
Stress Sharing Between the Sinus and Leaflets of Canine Aortic Valve
Thubrikar, M. J., Nolan, S. P., Aouad, J., & Deck, J. D. (1986) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(10)60554-1 · Cited by 123
The myth of the aortic annulus: The anatomy of the subaortic outflow tract
Anderson, R. H., Devine, W. A., Ho, S. Y., Smith, A., & McKay, R. (1991) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(91)90966-t · Cited by 118
Normal aortic valve function in dogs
Thubrikar, M. J., Harry, R., & Nolan, S. P. (1977) · The American Journal of Cardiology · doi:10.1016/0002-9149(77)90072-8 · Cited by 73
Dynamic deformation experiments on aortic tissue
Collins, R., & Hu, W. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90062-0 · Cited by 43
Moon, M. R., Castro, L. J., DeAnda, A., Daughters, G. T., Ingels, N. B., & Miller, D. C. (1994) · PubMed · Cited by 21
Self-citation
Cited by
Hockaday, L. A., Kang, K. H., Colangelo, N. W., Cheung, P. Y. C., Duan, B., Malone, E., Wu, J., Girardi, L. N., Bonassar, L. J., Lipson, H., et al. (2012) · Biofabrication · doi:10.1088/1758-5082/4/3/035005 · Cited by 683
El-Hamamsy, I., Eryigit, Z., Stevens, L.-M., Sarang, Z., George, R., Clark, L., Melina, G., Takkenberg, J. J., & Yacoub, M. H. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60828-8 · Cited by 377
On the biomechanics of heart valve function
Sacks, M. S., David Merryman, W., & Schmidt, D. E. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.015 · Cited by 372
Medical Management of Marfan Syndrome
Keane, M. G., & Pyeritz, R. E. (2008) · Circulation · doi:10.1161/circulationaha.107.693523 · Cited by 295
Ross Procedure in Adults for Cardiologists and Cardiac Surgeons
Mazine, A., El-Hamamsy, I., Verma, S., Peterson, M. D., Bonow, R. O., Yacoub, M. H., David, T. E., & Bhatt, D. L. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.2200 · Cited by 217
“These expansile and contractile deformations— which occur at the level of the annulus, sinuses of Valsalva, and sinotubular junction—play an important role in minimizing aortic cusp stress, promoting laminar flow during systole, and enhancing coronary flow reserve in systole and diastole (50).”
Background
Metadata
- Authors
- Dagum, P., Green, G. R., Nistal, F. J., Daughters, G. T., Timek, T. A., Foppiano, L. E., Bolger, A. F., Ingels, N. B., & Miller, D. C.
- Venue
- Circulation
- Published
- 1999-11-09
- Volume
- 100
- Issue
- Supplement 2
- Pages
- II-54-II-62
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2167320377
- Cited by
- 186
- References
- 12
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.