The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Dimensions and Geometric Relationships of the Human Aortic Value as a Function of Pressure
Abstract
In a continuing effort to develop improved prosthetic heart valves, a redefinition of the anatomy of the human aortic valve as a function of stress was undertaken. Dimensions and geometric relationships of the human aortic valve as a function of intraaortic pressure between 0 and 120 mm Hg were obtained from a series of silicone rubber valve casts. The axial length of the valve region was found to vary negligibly with pressure, but significant variations in geometry and angular dimensions were seen. The leaflet attachment annulus forms an ellipse at the plane of intersection with the cylindrical surface passing from the left ventricular tract through the aorta. Deductions from stress considerations for the measured geometry indicate that the loaded leaflet is a section of a cylindrical surface. The equation for this developed surface was obtained, and a prosthetic design was determined using average values at 100 mm Hg. The leaflet is developable onto a plane with a cut required along part of the junction line between the initially cylindrical part and the plane coapting surfaces. Optimum valve shape mandates a base angle between the cylindrical leaflet and the center axis of 70° (α =20-22°, where α is the leaflet angle).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Minns, R. J., Soden, P. D., & Jackson, D. S. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90084-5 · Cited by 189
Clark, R. E. (1973) · PubMed · Cited by 128
Self-citationArndt, J. O., & Kober, G. (1970) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00586492 · Cited by 34
Cited by
David, T. E., & Feindel, C. M. (1992) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)34942-6 · Cited by 1,286
Piazza, N., de Jaegere, P., Schultz, C., Becker, A. E., Serruys, P. W., & Anderson, R. H. (2008) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.108.780858 · Cited by 651
Substrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
The bioengineered cardiac left ventricle
Patel, N. M., & Birla, R. K. (2018) · ASAIO Journal · doi:10.1097/mat.0000000000000642 · Cited by 20
Metadata
- Authors
- SWANSON, W. M., & CLARK, R. E.
- Venue
- Circulation Research
- Published
- 1974-12
- Volume
- 35
- Issue
- 6
- Pages
- 871-882
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2098510103
- Cited by
- 350
- References
- 3
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dimensions and Geometric Relationships of the Human Aortic Value as a Function of Pressure. https://app.cochat.ai/papers/10.1161/01.res.35.6.871
- The paper
- SWANSON, W. M., & CLARK, R. E. (1974). Dimensions and Geometric Relationships of the Human Aortic Value as a Function of Pressure. Circulation Research. https://doi.org/10.1161/01.res.35.6.871
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.