The DOI matches its Crossref record; 42 of the 43 references it cites were found in a registry or an index.
Clinical Outcomes After Ablation and Pacing Therapy for Atrial Fibrillation: A Meta-Analysis
Abstract
BACKGROUND: Radiofrequency ablation of the atrioventricular node and permanent pacing are used for symptomatic relief in patients with medically refractory atrial fibrillation. In this study, meta-analysis was used to clarify clinical outcomes and survival after ablation and pacing therapy using data from the published literature. METHODS AND RESULTS: We used 21 studies with a total of 1181 patients in the meta-analysis. All patients had medically refractory atrial tachyarrhythmias, primarily atrial fibrillation (97%). Nineteen measures of clinical outcome, encompassing quality of life, ventricular function, exercise duration, and healthcare use, were derived from the studies. The meta-analysis demonstrated significant improvement after ablation and pacing therapy in all outcome measures except fractional shortening, which demonstrated a trend toward improvement (P=0.08). Ejection fraction did show significant improvement (P<0.001). The calculated 1-year total and sudden death mortality rates after ablation and pacing therapy were 6.3% and 2.0%, respectively. CONCLUSIONS: Ablation and pacing therapy improves a broad range of clinical outcomes for patients with medically refractory atrial fibrillation. The calculated 1-year mortality rates after this therapy are low and comparable with medical therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The procedure does not worsen LV function 567 and may even improve LVEF in selected patients.[568][569][570]”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [569]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Primary, Secondary, and Meta-Analysis of Research
GLASS, G. V. (1976) · Educational Researcher · doi:10.3102/0013189x005010003 · Cited by 4,890
The Handbook of Research Synthesis.
Howel, D., Cooper, H., & Hedges, L. V. (1995) · Biometrics · doi:10.2307/2533295 · Cited by 3,657
Kannel, W. B., Wolf, P. A., Benjamin, E. J., & Levy, D. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00583-9 · Cited by 2,033
Meta-Analyses of Randomized Controlled Trials
Sacks, H. S., Berrier, J., Reitman, D., Ancona-Berk, V. A., & Chalmers, T. C. (1987) · New England Journal of Medicine · doi:10.1056/nejm198702193160806 · Cited by 1,257
Tachycardia-Induced Cardiomyopathy: A Review of Animal Models and Clinical Studies
Shinbane, J. S., Wood, M. A., Jensen, D. N., Ellenbogen, K. A., Fitzpatrick, A. P., & Scheinman, M. M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00592-x · Cited by 800
Management of Patients With Atrial Fibrillation
Prystowsky, E. N., Benson, D. W., Fuster, V., Hart, R. G., Kay, G. N., Myerburg, R. J., Naccarelli, G. V., & Wyse, D. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1262 · Cited by 638
Antiarrhythmic drug therapy and cardiac mortality in atrial fibrillation
Flaker, G. C., Blackshear, J. L., McBride, R., Kronmal, R. A., Halperin, J. L., & Hart, R. G. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90003-6 · Cited by 633
Effect of an irregular ventricular rhythm on cardiac output
Daoud, E. G., Weiss, R., Bahu, M., Knight, B. P., Bogun, F. M., Goyal, R., Harvey, M. N., Strickberger, S. A., Man, K. C., & Morady, F. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)89297-1 · Cited by 361
Large Trials vs Meta-analysis of Smaller Trials: How Do Their Results Compare?
Cappelleri, J. C. (1996) · JAMA · doi:10.1001/jama.1996.03540160054033 · Cited by 336
Research works printed but not linked: 8
- 10.1161/circ.94.7.1585 · DOI
- 10.1161/circ.93.6.1262 · DOI
- 10.1161/circ.96.8.2617 · DOI
- 10.1001/jama.1988.03720110047033 · DOI
- 10.1161/circ.83.5.2022016 · DOI
- 10.1161/circ.84.5.1934368 · DOI
- Gjesdal K, Platou ES, Aass H, Orning OM. Ablasjon av His-bunten ved atriale arytmier: en utvei nar medikamentene ikke virker. Tidsskr Nor Laegeforen. 1996;116:3222–3225.
- 10.1161/circ.98.10.953 · DOI
Cited by
Sorted by citations
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O. D., et al. (2021) · PubMed · doi:10.1093/eurheartj/ehab670 · Cited by 20,604
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström‐Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 10,550
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H. G., Cigarroa, J. E., Cleveland, J. C., CONTI, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,145
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,438
Metadata
- Authors
- Wood, M. A., Brown-Mahoney, C., Kay, G. N., & Ellenbogen, K. A.
- Affiliations
- University of Minnesota (US)
- Venue
- Circulation
- Published
- 2000-03-14
- Volume
- 101
- Issue
- 10
- Pages
- 1138-1144
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2069728923
- Cited by
- 476
- References
- 43
- Citations by year
- 2026: 12 · 2025: 9 · 2024: 9 · 2023: 13 · 2022: 19 · 2021: 16 · 2020: 7 · 2019: 5 · 2018: 11 · 2017: 9 · 2016: 15 · 2015: 6 · 2014: 15 · 2013: 18 · 2012: 26
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- atrial fibrillation, radiofrequency catheter ablation, atrioventricular node ablation, permanent pacemaker, mortality, sudden death, quality of life, ejection fraction, ventricular function, health care utilization
- MeSH terms
- Aged, Atrial Fibrillation, Cardiac Pacing, Artificial, Clinical Trials as Topic, Female, Humans, Male, Middle Aged, Survival Analysis, Treatment Outcome, Catheter Ablation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review