Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 868

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Ambient Pollution and Heart Rate Variability

Gold, Diane R., Litonjua, Augusto, Schwartz, Joel, Lovett, Eric, Larson, Andrew, Nearing, Bruce, Allen, George, Verrier, Monique, Cherry, Rebecca, Verrier, Richard·2000·Circulation

Abstract

Background —We investigated associations between ambient pollution levels and cardiovascular function in a repeated measures study including 163 observations on twenty-one 53- to 87-year-old active Boston residents observed up to 12 times from June to September 1997. Particles with aerodynamic diameter ≤2.5 μm (PM 2.5 ) were measured continuously using a tapered element oscillating microbalance. Methods and Results —The protocol involved 25 minutes per week of continuous Holter ECG monitoring, including 5 minutes of rest, 5 minutes of standing, 5 minutes of exercise outdoors, 5 minutes of recovery, and 20 cycles of slow breathing. Heart rate variability (HRV) was assessed through time domain variables: the standard deviation of normal RR intervals (SDNN) and the square root of the mean of the squared differences between adjacent normal RR intervals (r-MSSD). Mean 4-hour PM 2.5 levels ranged from 3 to 49 μg/m 3 ; 1-hour ozone levels ranged from 1 to 77 ppb. In multivariate analyses, significantly less HRV (SDNN and r-MSSD) was associated with elevated PM 2.5 . During slow breathing, a reduction in r-MSSD of 6.1 ms was associated with an interquartile (14.3 μg/m 3 ) increase in PM 2.5 during the hour of and the 3 hours previous to the Holter session ( P =0.006). During slow breathing, a multiple pollution model was associated with a reduction in r-MSSD of 5.4 ms ( P =0.02) and 5.5 ms ( P =0.03) for interquartile changes in PM 2.5 and ozone, respectively, resulting in a combined effect equivalent to a 33% reduction in the mean r-MSSD. Conclusions —Particle and ozone exposure may decrease vagal tone, resulting in reduced HRV.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.101.11.1267

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 868

Metadata

Authors
Gold, D. R., Litonjua, A., Schwartz, J., Lovett, E., Larson, A., Nearing, B., Allen, G., Verrier, M., Cherry, R., & Verrier, R.
Venue
Circulation
Published
2000-03-21
Volume
101
Issue
11
Pages
1267-1273
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2148316980
Cited by
868
References
4
FWCI
45.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ambient Pollution and Heart Rate Variability. https://app.cochat.ai/papers/10.1161/01.cir.101.11.1267
The paper
Gold, D. R., Litonjua, A., Schwartz, J., Lovett, E., Larson, A., Nearing, B., Allen, G., Verrier, M., Cherry, R., & Verrier, R. (2000). Ambient Pollution and Heart Rate Variability. Circulation. https://doi.org/10.1161/01.cir.101.11.1267

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.