The DOI matches its Crossref record.
Linear Ablation Lesions for Control of Unmappable Ventricular Tachycardia in Patients With Ischemic and Nonischemic Cardiomyopathy
Abstract
Background —Conventional activation mapping is difficult without inducible, stable ventricular tachycardia (VT). Methods and Results —We evaluated 16 patients with drug refractory, unimorphic, unmappable VT. Nine patients had ischemic and 7 had nonischemic cardiomyopathy. All patients had implantable defibrillators and had experienced 6 to 55 VT episodes during the month before treatment. Patients underwent bipolar catheter mapping during baseline rhythm. The amount of endocardium with an abnormal electrogram amplitude was estimated using fluoroscopy in 3 patients and a magnetic mapping system (CARTO) in 13 patients. For the magnetic mapping, normal endocardium was defined by an amplitude >1.5 mV; this measurement was based on sinus rhythm maps in 6 patients who did not have structural heart disease. Radiofrequency point lesions extended linearly from the “dense scar,” which had a voltage amplitude <0.5 mV, to anatomic boundaries or normal endocardium. To limit radiofrequency applications, 12-lead ECG during VT and pacemapping guided placement of linear lesions. No new antiarrhythmic drug therapy was added. The amount of endocardium demonstrating an abnormal electrogram amplitude ranged from 25 to 127 cm 2 . A total of 8 to 87 radiofrequency lesions (mean, 55) produced a median of 4 linear lesions that had an average length of 3.9 cm (range, 1.4 to 9.4 cm). Twelve patients (75%) have been free of VT during 3 to 36 months of follow-up (median, 8 months); 4 patients had VT episodes at 1, 3, 9, and 13 months, respectively. Only one of these patient had frequent VT. Conclusions —Radiofrequency linear endocardial lesions extending from the dense scar to the normal myocardium or anatomic boundary seem effective in controlling unmappable VT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy
Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065457 · Cited by 959
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Self-citationTung, R., Vaseghi, M., Frankel, D. S., Vergara, P., Di Biase, L., Nagashima, K., Yu, R., Vangala, S., Tseng, C.-H., Choi, E.-K., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.036 · Cited by 499
Self-citation
Metadata
- Authors
- Marchlinski, F. E., Callans, D. J., Gottlieb, C. D., & Zado, E.
- Venue
- Circulation
- Published
- 2000-03-21
- Volume
- 101
- Issue
- 11
- Pages
- 1288-1296
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1967033073
- Cited by
- 1,220
- References
- 0
- FWCI
- 17.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Linear Ablation Lesions for Control of Unmappable Ventricular Tachycardia in Patients With Ischemic and Nonischemic Cardiomyopathy. https://app.cochat.ai/papers/10.1161/01.cir.101.11.1288
- The paper
- Marchlinski, F. E., Callans, D. J., Gottlieb, C. D., & Zado, E. (2000). Linear Ablation Lesions for Control of Unmappable Ventricular Tachycardia in Patients With Ischemic and Nonischemic Cardiomyopathy. Circulation. https://doi.org/10.1161/01.cir.101.11.1288
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.