Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 578

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Noninvasive Detection of Myocardial Ischemia From Perfusion Reserve Based on Cardiovascular Magnetic Resonance

Open access
Al-Saadi, Nidal, Nagel, Eike, Gross, Michael, Bornstedt, Axel, Schnackenburg, Bernhard, Klein, Christoph, Klimek, Waldemar, Oswald, Helmut, Fleck, Eckart·2000·Circulation

Abstract

Background —Myocardial perfusion reserve can be noninvasively assessed with cardiovascular MR. In this study, the diagnostic accuracy of this technique for the detection of significant coronary artery stenosis was evaluated. Methods and Results —In 15 patients with single-vessel coronary artery disease and 5 patients without significant coronary artery disease, the signal intensity–time curves of the first pass of a gadolinium-DTPA bolus injected through a central vein catheter were evaluated before and after dipyridamole infusion to validate the technique. A linear fit was used to determine the upslope, and a cutoff value for the differentiation between the myocardium supplied by stenotic and nonstenotic coronary arteries was defined. The diagnostic accuracy was then examined prospectively in 34 patients with coronary artery disease and was compared with coronary angiography. A significant difference in myocardial perfusion reserve between ischemic and normal myocardial segments (1.08±0.23 and 2.33±0.41; P <0.001) was found that resulted in a cutoff value of 1.5 (mean minus 2 SD of normal segments). In the prospective analysis, sensitivity, specificity, and diagnostic accuracy for the detection of coronary artery stenosis (≥75%) were 90%, 83%, and 87%, respectively. Interobserver and intraobserver variabilities for the linear fit were low ( r =0.96 and 0.99). Conclusions —MR first-pass perfusion measurements yielded a high diagnostic accuracy for the detection of coronary artery disease. Myocardial perfusion reserve can be easily and reproducibly determined by a linear fit of the upslope of the signal intensity–time curves.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.101.12.1379

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 578

Metadata

Authors
Al-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E.
Venue
Circulation
Published
2000-03-28
Volume
101
Issue
12
Pages
1379-1383
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2103476848
Cited by
578
References
17
FWCI
25.36
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Detection of Myocardial Ischemia From Perfusion Reserve Based on Cardiovascular Magnetic Resonance. https://app.cochat.ai/papers/10.1161/01.cir.101.12.1379
The paper
Al-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000). Noninvasive Detection of Myocardial Ischemia From Perfusion Reserve Based on Cardiovascular Magnetic Resonance. Circulation. https://doi.org/10.1161/01.cir.101.12.1379

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.