Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 233

The DOI matches its Crossref record.

Design of a New Surgical Approach for Ventricular Remodeling to Relieve Ischemic Mitral Regurgitation: Insights From 3-Dimensional Echocardiography

Liel-Cohen, Noah, Guerrero, J. Luis, Otsuji, Yutaka, Handschumacher, Mark D., Rudski, Lawrence G., Hunziker, Patrick R., Tanabe, Hiroaki, Scherrer-Crosbie, Marielle, Sullivan, Suzanne, Levine, Robert A. · 2000 · Circulation

Abstract

Background —Mechanistic insights from 3D echocardiography (echo) can guide therapy. In particular, ischemic mitral regurgitation (MR) is difficult to repair, often persisting despite annular reduction. We hypothesized that (1) in a chronic infarct model of progressive MR, regurgitation parallels 3D changes in the geometry of mitral leaflet attachments, causing increased leaflet tethering and restricting closure; therefore, (2) MR can be reduced by restoring tethering geometry toward normal, using a new ventricular remodeling approach based on 3D echo findings. Methods and Results —We studied 10 sheep by 3D echo just after circumflex marginal ligation and 8 weeks later. MR, at first absent, became moderate as the left ventricle (LV) dilated and the papillary muscles shifted posteriorly and mediolaterally, increasing the leaflet tethering distance from papillary muscle tips to the anterior mitral annulus ( P <0.0001). To counteract these shifts, the LV was remodeled by plication of the infarct region to reduce myocardial bulging, without muscle excision or cardiopulmonary bypass. Immediately and up to 2 months after plication, MR was reduced to trace-to-mild as tethering distance was decreased ( P <0.0001). LV ejection fraction, global LV end-systolic volume, and mitral annular area were relatively unchanged. By multiple regression, the only independent predictor of MR was tethering distance ( r 2 =0.81). Conclusions —Ischemic MR in this model relates strongly to changes in 3D mitral leaflet attachment geometry. These insights from quantitative 3D echo allowed us to design an effective LV remodeling approach to reduce MR by relieving tethering.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.101.23.2756

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 233

Metadata

Authors
Liel-Cohen, N., Guerrero, J. L., Otsuji, Y., Handschumacher, M. D., Rudski, L. G., Hunziker, P. R., Tanabe, H., Scherrer-Crosbie, M., Sullivan, S., & Levine, R. A.
Venue
Circulation
Published
2000-06-13
Volume
101
Issue
23
Pages
2756-2763
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2041058171
Cited by
233
References
0
FWCI
7.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design of a New Surgical Approach for Ventricular Remodeling to Relieve Ischemic Mitral Regurgitation: Insights From 3-Dimensional Echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.101.23.2756
The paper
Liel-Cohen, N., Guerrero, J. L., Otsuji, Y., Handschumacher, M. D., Rudski, L. G., Hunziker, P. R., Tanabe, H., Scherrer-Crosbie, M., Sullivan, S., & Levine, R. A. (2000). Design of a New Surgical Approach for Ventricular Remodeling to Relieve Ischemic Mitral Regurgitation: Insights From 3-Dimensional Echocardiography. Circulation. https://doi.org/10.1161/01.cir.101.23.2756

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.