Dual-Loop Intra-Atrial Reentry in Humans
The DOI matches its Crossref record.
Abstract
Background —Dual-loop atrial reentrant tachycardias have not been clinically described. Methods and Results —Five patients (3 men, 2 women; mean age, 48±16 years) were studied 24±15 years after surgical closure of an ostium secundum atrial septal defect for drug-resistant atrial tachycardia. Complete tachycardia mapping was performed in the right atrium with multipolar catheters and a 3-dimensional electroanatomic mapping system (Biosense), followed by linear radiofrequency ablation of the narrowest part of each complete loop. Six tachycardias with a typical flutter morphology, a cycle length of 262±40 ms, and a superior f-wave axis (−77±11°) were mapped, 4 with a Biosense map including 106±32 points. Five figure-8 tachycardias had a counterclockwise loop around the tricuspid valve sharing a common anterior channel with a clockwise loop around the lateral atriotomy scar. One tachycardia was thought to have 2 counterclockwise loops around the same obstacles. Radiofrequency delivery in the cavotricuspid isthmus in each case transformed the tachycardia without any pause in a different morphology tachycardia with an inferior P-wave axis (50±42°) and nearly the same cycle length (272±39 ms) but with the periatriotomy loop alone. This arrhythmia required ablation of a second isthmus: between the lower end of the atriotomy and the inferior vena cava in 4 and the superior tricuspid annulus in 1. After a follow-up of 19±6 months, there were no recurrences. Conclusions —Figure-8 double-loop tachycardias mimicking the ECG pattern of a common atrial flutter occur in some patients after a surgical atriotomy. Ablation of 1 loop produces a sudden transformation to a new reentrant tachycardia formed of the remaining loop that requires ablation at a second isthmus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brugada, J., Katritsis, D. G., Arbelo, E., Arribas, F., Bax, J. J., Blomström-Lundqvist, C., Calkins, H., Corrado, D., Deftereos, S. G., Diller, G.-P., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz467 · Cited by 1,230
Blomstrom-Lundqvist (2003) · doi:10.1161/01.cir.0000091380.04100.84 · Cited by 955
Blomström-Lundqvist, C., Scheinman, M. M., Aliot, E. M., Alpert, J. S., Calkins, H., Camm, A. J., Campbell, W. B., Haines, D. E., Kuck, K. H., Lerman, B. B., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.013 · Cited by 689
Philip Saul, J., Kanter, R. J., Abrams, D., Asirvatham, S., Bar-Cohen, Y., Blaufox, A. D., Cannon, B., Clark, J., Dick, M., Freter, A., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.02.009 · Cited by 272
BlomstromLundqvist, C. (2003) · European Heart Journal · doi:10.1016/j.ehj.2003.08.002 · Cited by 263
Left atrial linear lesions are required for successful treatment of persistent atrial fibrillation
Knecht, S., Hocini, M., Wright, M., Lellouche, N., O'Neill, M. D., Matsuo, S., Nault, I., Chauhan, V. S., Makati, K. J., Bevilacqua, M., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn302 · Cited by 259
Self-citationOuyang, F., Ernst, S., Vogtmann, T., Goya, M., Volkmer, M., Schaumann, A., Bänsch, D., Antz, M., & Kuck, K.-H. (2002) · Circulation · doi:10.1161/01.cir.0000015077.12680.2e · Cited by 212
“Atrial tachycardia recurred in 4 patients: 3 patients without validated block across the isthmus presented with recurrence of the same LAMRT, and 1 patient without ablated cavotricuspid isthmus presented with AFL.”
BackgroundMethodInfluentialA novel pacing maneuver to localize focal atrial tachycardia
MOHAMED, U., SKANES, A. C., GULA, L. J., LEONG‐SIT, P., KRAHN, A. D., YEE, R., SUBBIAH, R., & KLEIN, G. J. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00664.x · Cited by 164
Lukac, P., Pedersen, A. K., Mortensen, P. T., Jensen, H. K., Hjortdal, V., & Hansen, P. S. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2004.10.034 · Cited by 123
Atrial flutter: more than just one of a kind
Bun, S.-S., Latcu, D. G., Marchlinski, F., & Saoudi, N. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv118 · Cited by 115
Lesional tachycardias related to mitral valve surgery
Markowitz, S. M., Brodman, R. F., Stein, K. M., Mittal, S., Slotwiner, D. J., Iwai, S., Das, M. K., & Lerman, B. B. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01905-8 · Cited by 97
Wasmer, K., Köbe, J., Dechering, D. G., Bittner, A., Mönnig, G., Milberg, P., Baumgartner, H., Breithardt, G., & Eckardt, L. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.03.012 · Cited by 46
Metadata
- Authors
- Shah, D., Jaïs, P., Takahashi, A., Hocini, M., Peng, J. T., Clementy, J., & Haïssaguerre, M.
- Venue
- Circulation
- Published
- 2000-02-15
- Volume
- 101
- Issue
- 6
- Pages
- 631-639
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2070546795
- Cited by
- 146
- References
- 0
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.