CoChat
Cited by 1,078

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Myocardial Strain by Doppler Echocardiography: Validation of a New Method to Quantify Regional Myocardial Function

Open access
Urheim, Stig, Edvardsen, Thor, Torp, Hans, Angelsen, Bjørn, Smiseth, Otto A. · 2000 · Circulation

Abstract

Background —Myocardial strain is a measure of regional deformation, and by definition, negative strain means shortening and positive strain, elongation. This study investigates whether myocardial strain can be measured by Doppler echocardiography as the time integral of regional velocity gradients, using sonomicrometry as reference method. Methods and Results —In 13 anesthetized dogs, myocardial longitudinal strain was measured on apical images as the time integral of regional Doppler velocity gradients. Ultrasonic segment-length crystals were placed near the left ventricular (LV) apex and near the base. Apical ischemia was induced by occluding the left anterior descending coronary artery (LAD), and preload was increased by saline. Percentage systolic strain by Doppler correlated well with strain by sonomicrometry ( y =0.82 x −1.79, r =0.92, P <0.01). During LAD occlusion, apical myocardium became dyskinetic, as indicated by positive strain values and negative Doppler velocities. At the LV base, myocardial strain by Doppler, strain by sonomicrometry, and velocity of shortening by sonomicrometry (dL/dt) were unchanged during apical ischemia. However, myocardial Doppler velocities at the base decreased from 4.2±0.7 (±SEM) to 2.7±0.4 cm/s ( P <0.05), probably reflecting loss of motion caused by tethering to apical segments. Volume loading increased myocardial Doppler velocities from 2.2±0.3 to 4.1±0.8 cm/s ( P <0.05) and Doppler-derived strain from −12±1% to −22±2% ( P <0.05), whereas peak LV elastance remained unchanged. Conclusions —Myocardial strain by Doppler echocardiography may represent a new, powerful method for quantifying regional myocardial function and is less influenced by tethering effects than Doppler tissue imaging. Like myocardial Doppler velocities, strain is markedly load-dependent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.102.10.1158

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 1,078

Metadata

Authors
Urheim, S., Edvardsen, T., Torp, H., Angelsen, B., & Smiseth, O. A.
Venue
Circulation
Published
2000-09-05
Volume
102
Issue
10
Pages
1158-1164
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2099916373
Cited by
1,078
References
12
FWCI
18.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.