Electrical Remodeling of the Atria Associated With Paroxysmal and Chronic Atrial Flutter
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background —Atrial electrical remodeling may be important for the initiation and perpetuation of atrial arrhythmias. Whether paroxysmal atrial flutter (AFL) and chronic AFL cause electrical remodeling of the atria has not been conclusively determined. Methods and Results —Before radiofrequency ablation of paroxysmal AFL, 15 patients in sinus rhythm were evaluated under autonomic blockade. Lateral right atrial (LRA) effective refractory periods (ERPs) at 600 and 450 ms were measured before and at 1-minute intervals for 10 minutes after spontaneous or pace termination of a 5- to 10-minute period of induced AFL. In 10 patients with chronic AFL, LRA, septal, and coronary sinus (CS) ERPs and corrected sinus node recovery times (cSNRTs) at 600 and 450 ms were measured under autonomic blockade 15 minutes, 30 minutes, and 3 weeks after termination of chronic AFL by ablation. In the paroxysmal AFL group, LRA ERPs decreased by 18% at 600 ms and 12% at 450 ms ( P <0.01) after induced AFL and recovered to baseline over ≈5 minutes. Atrial fibrillation developed during AFL in 3 patients and during ERP testing in 3 patients when refractoriness was at its nadir. In the chronic AFL group, LRA, septal, and CS ERPs at 3 weeks were significantly greater than at 15 and 30 minutes after termination of chronic AFL at both cycle lengths ( P <0.01). Three weeks after ablation, cSNRT decreased 35% at 600 ms ( P <0.05) and decreased 44% at 450 ms ( P <0.05). Both ERPs and cSNRTs measured 15 and 30 minutes after ablation of chronic AFL were not significantly different. Conclusions —Both paroxysmal AFL and chronic AFL cause reversible electrical remodeling of the atria but demonstrate different time courses of recovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Franz, M. R., Karasik, P. L., Li, C., Moubarak, J., & Chavez, M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00385-9 · Cited by 301
Right Atrial Flutter Due to Lower Loop Reentry: Mechanism and Anatomic Substrates
Cheng, J., Cabeen, W. R., & Scheinman, M. M. (1999) · Circulation · doi:10.1161/01.cir.99.13.1700 · Cited by 152
Schumacher, B., Jung, W., Schmidt, H., Fischenbeck, C., Lewalter, T., Hagendorff, A., Omran, H., Wolpert, C., & Lüderitz, B. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00211-9 · Cited by 104
Alterations in atrial electrophysiology associated with chronic atrial fibrillation in man
Kamalvand, K. (1999) · European Heart Journal · doi:10.1053/euhj.1998.1404 · Cited by 47
Cited by
New Insights Into Pacemaker Activity: Promoting Understanding of Sick Sinus Syndrome
Dobrzynski, H., Boyett, M. R., & Anderson, R. H. (2007) · Circulation · doi:10.1161/circulationaha.106.616011 · Cited by 429
Kim, Y. M., Guzik, T. J., Zhang, Y. H., Zhang, M. H., Kattach, H., Ratnatunga, C., Pillai, R., Channon, K. M., & Casadei, B. (2005) · Circulation Research · doi:10.1161/01.res.0000183735.09871.61 · Cited by 405
Workman, A. (2001) · Cardiovascular Research · doi:10.1016/s0008-6363(01)00380-7 · Cited by 271
Sinus Node and Atrial Arrhythmias
John, R. M., & Kumar, S. (2016) · Circulation · doi:10.1161/circulationaha.116.018011 · Cited by 215
“Following ablation of atrial flutter, corrected SN recovery time decreased by 35% 3 weeks after ablation, suggesting that the atrial arrhythmia has a reversible effect on SN function.(32)”
BackgroundReversal of Electrical Remodeling After Cardioversion of Persistent Atrial Fibrillation
RAITT, M. H., KUSUMOTO, W., GIRAUD, G., & MCANULTY, J. H. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03217.x · Cited by 87
Metadata
- Authors
- Sparks, P. B., Jayaprakash, S., Vohra, J. K., & Kalman, J. M.
- Venue
- Circulation
- Published
- 2000-10-10
- Volume
- 102
- Issue
- 15
- Pages
- 1807-1813
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2157990041
- Cited by
- 126
- References
- 4
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.