Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 166

The DOI matches its Crossref record.

Impact of Atrioventricular Compliance on Pulmonary Artery Pressure in Mitral Stenosis: An Exercise Echocardiographic Study

Schwammenthal, Ehud, Vered, Zvi, Agranat, Oren, Kaplinsky, Elieser, Rabinowitz, Babeth, Feinberg, Micha S.·2000·Circulation

Abstract

Background —The decay of the pressure gradient across a stenotic mitral valve is determined by the size of the orifice and net AV compliance (C n ). We have observed a group of symptomatic patients, usually in sinus rhythm, characterized by pulmonary hypertension (particularly during exercise) despite a relatively large mitral valve area by pressure half-time. We speculated that this discrepancy was due to low atrial compliance causing both pulmonary hypertension and a steep decay of the transmitral pressure gradient despite significant stenosis. We therefore tested the hypothesis that C n is an important physiological determinant of pulmonary artery pressure at rest and during exercise in mitral stenosis. Methods and Results —Twenty patients with mitral stenosis were examined by Doppler echocardiography. C n , calculated from the ratio of effective mitral valve area (continuity equation) and the E-wave downslope, ranged from 1.7 to 8.1 mL/mm Hg. Systolic pulmonary artery pressure (PAP) increased from 43±12 mm Hg at rest to 71±23 mm Hg (range, 40 to 110 mm Hg) during exercise. There was a particularly close correlation between C n and exercise PAP ( r =−0.85). Patients with a low compliance were more symptomatic ( P <0.025). Catheter- and Doppler-derived values for C n , determined in 10 cases, correlated well ( r =0.79). Conclusions —C n , which can be noninvasively assessed, is an important physiological determinant of PAP in mitral stenosis. Patients with low C n represent an important clinical entity, with symptoms corresponding to severe increases in PAP during stress echocardiography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.102.19.2378

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Schwammenthal, E., Vered, Z., Agranat, O., Kaplinsky, E., Rabinowitz, B., & Feinberg, M. S.
Venue
Circulation
Published
2000-11-07
Volume
102
Issue
19
Pages
2378-2384
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2162315497
Cited by
166
References
0
FWCI
0.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of Atrioventricular Compliance on Pulmonary Artery Pressure in Mitral Stenosis: An Exercise Echocardiographic Study. https://app.cochat.ai/papers/10.1161/01.cir.102.19.2378
The paper
Schwammenthal, E., Vered, Z., Agranat, O., Kaplinsky, E., Rabinowitz, B., & Feinberg, M. S. (2000). Impact of Atrioventricular Compliance on Pulmonary Artery Pressure in Mitral Stenosis: An Exercise Echocardiographic Study. Circulation. https://doi.org/10.1161/01.cir.102.19.2378

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.