The DOI matches its Crossref record.
Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary Veins
Open accessAbstract
Background —The extent of ostial ablation necessary to electrically disconnect the pulmonary vein (PV) myocardial extensions that initiate atrial fibrillation from the left atrium has not been determined. Methods and Results —Seventy patients underwent PV mapping with a circumferential 10-electrode catheter during sinus rhythm or left atrial pacing. After assessment of perimetric distribution and activation sequence of PV potentials, ostial ablation was performed at segments showing earliest activation, with the end point of PV disconnection. A total of 162 PVs (excluding right inferior PVs) were ablated. PV potentials were present at 60% to 88% of their perimeter, but PV muscle activation was always sequential from a segment with earliest activation (breakthrough). Radiofrequency (RF) application at this breakthrough eliminated all PV potentials in 34 PVs, whereas a secondary breakthrough required RF applications at separate segments in 77; in others, >2 segments were ablated. A median of 5, 6, and 4 bipoles from the circular catheter were targeted in the right superior, left superior, and inferior PVs, respectively, to achieve PV disconnection. Early recurrence of arrhythmia was observed in 31 patients as a result of new venous or atrial foci or recovery of previously targeted PVs, most related to a single recovered breakthrough that was reablated with local RF application. Conclusions —Although PV muscle covers a large extent of the PV perimeter, there are specific breakthroughs from the left atrium that allow ostial PV disconnection by use of partial perimetric ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214876d · Cited by 859
Mechanisms of organized left atrial tachycardias occurring after pulmonary vein isolation
Gerstenfeld, E. P., Callans, D. J., Dixit, S., Russo, A. M., Nayak, H., Lin, D., Pulliam, W., Siddique, S., & Marchlinski, F. E. (2004) · Circulation · doi:10.1161/01.cir.0000141369.50476.d3 · Cited by 300
Kuck, K.-H., Hoffmann, B. A., Ernst, S., Wegscheider, K., Treszl, A., Metzner, A., Eckardt, L., Lewalter, T., Breithardt, G., & Willems, S. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003337 · Cited by 261
Corrado, C., Williams, S., Karim, R., Plank, G., O’Neill, M., & Niederer, S. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.04.005 · Cited by 50
Metadata
- Authors
- Haïssaguerre, M., Shah, D. C., Jaïs, P., Hocini, M., Yamane, T., Deisenhofer, I., Chauvin, M., Garrigue, S., & Clémenty, J.
- Venue
- Circulation
- Published
- 2000-11-14
- Volume
- 102
- Issue
- 20
- Pages
- 2463-2465
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2139011872
- Cited by
- 952
- References
- 0
- FWCI
- 32.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary Veins. https://app.cochat.ai/papers/10.1161/01.cir.102.20.2463
- The paper
- Haïssaguerre, M., Shah, D. C., Jaïs, P., Hocini, M., Yamane, T., Deisenhofer, I., Chauvin, M., Garrigue, S., & Clémenty, J. (2000). Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary Veins. Circulation. https://doi.org/10.1161/01.cir.102.20.2463
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.