The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Transcatheter Implantation of a Bovine Valve in Pulmonary Position: A Lamb Study
Abstract
Background —Pulmonary regurgitation can lead to severe right ventricular dysfunction, which is a delicate postoperative problem in the long-term follow-up of patients who had surgery for congenital heart diseases. Clinical conditions of patients suffering from pulmonary valve incompetence are improved by valve replacement with a prosthetic valve. To date, the surgical approach is the only option to replace a pulmonary valve. We report the first experience of percutaneous pulmonary valve implantation. Methods and Results —A fresh bovine jugular vein containing a native valve was sutured into a vascular stent and then cross-linked with a 0.6% glutaraldehyde solution for 36 hours. After being hand-crimped onto a balloon catheter, the device was inserted percutaneously according to standard stent-placing techniques. The valved stent was finally deployed in the position of the native pulmonary valve of the lamb. Hemodynamic evaluation was carried out before and 2 months after implantation. Anatomic evaluation was finally performed. Percutaneous pulmonary valve replacement was successful in 5 lambs. No complications were noted. Early and late angiographic and hemodynamic studies confirmed a good position of the stents with a competent valve at the end of the protocol. One stent was slightly stenotic, with macroscopically visible calcifications. Conclusions —Nonsurgical implantation of pulmonary valves is possible in the lamb. This new technique is similar to standard stent implantation. Thus, it should be feasible in humans, in whom it will lead to a significant reduction of reoperations in patients in need of pulmonary valve replacement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bove, E. L., Kavey, R.-E. W., Byrum, C. J., Sondheimer, H. M., Blackman, M. S., & Thomas, F. D. (1985) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)38661-1 · Cited by 165
Bove, E. L., Byrum, C. J., Fd, T., Kavey, R. E., Sondheimer, H. M., Ms, B., & Fb, P. (1983) · PubMed · Cited by 162
The Natural History of Isolated Congenital Pulmonary Valve Incompetence: Surgical Implications
Shimazaki, Y., Blackstone, E. H., & Kirklin, J. W. (1984) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-2007-1023399 · Cited by 157
Bove, E. L., Byrum, C. J., Thomas, F. D., Kavey, R.-E. W., Sondheimer, H. M., Blackman, M. S., & Parker, F. B. (1983) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)37504-x · Cited by 144
Canadian Consensus Conference on Adult Congenital Heart Disease 1996.
Connelly, M. S., Webb, G. D., Somerville, J., Warnes, C. A., Perloff, J. K., Liberthson, R. R., Puga, F. J., Collins-Nakai, R. L., Williams, W. G., Mercier, L., et al. (1998) · PubMed · Cited by 124
Surgical repair of tetralogy of Fallot
Zhao, H.-X., Miller, D. C., Reitz, B. A., & Shumway, N. E. (1985) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)38815-4 · Cited by 123
Impact of Glutaraldehyde on Calcification of Pericardial Bioprosthetic Heart Valve Material
Grabenwöger, M., Sider, J., Fitzal, F., Zelenka, C., Windberger, U. B., Grimm, M., Moritz, A., Böck, P., & Wolner, E. (1996) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(96)00442-0 · Cited by 100
Jones, E. L., Conti, C. R., Neill, C. A., Gott, V. L., Brawley, R. K., & Haller, J. A. (1973) · Circulation · doi:10.1161/01.cir.48.1s3.iii-11 · Cited by 45
Ilbawi, M. N., Idriss, F. S., DeLeon, S. Y., Muster, A. J., Berry, T. E., & Paul, M. H. (1986) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(10)63022-6 · Cited by 43
Comparative study between St. Jude Madical and bioprosthetic valves in the right side of the heart.
Kawachi, Y., Masuda, M., Tominaga, R., & Tokunaga, K. (1991) · Japanese Circulation Journal-english Edition · doi:10.1253/jcj.55.553 · Cited by 35
Cited by
Grube, E., Schuler, G., Buellesfeld, L., Gerckens, U., Linke, A., Wenaweser, P., Sauren, B., Mohr, F.-W., Walther, T., Zickmann, B., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.047 · Cited by 959
Feltes, T. F., Bacha, E., Beekman, R. H., Cheatham, J. P., Feinstein, J. A., Gomes, A. S., Hijazi, Z. M., Ing, F. F., de Moor, M., Morrow, W. R., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31821b1f10 · Cited by 853
Apitz, C., Webb, G. D., & Redington, A. N. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60657-7 · Cited by 653
Transcatheter Heart Valves: A Biomaterials Perspective
Bui, H. T., Khair, N., Yeats, B., Gooden, S., James, S. P., & Dasi, L. P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100115 · Cited by 36
Metadata
- Authors
- Bonhoeffer, P., Boudjemline, Y., Saliba, Z., Hausse, A. O., Aggoun, Y., Bonnet, D., Sidi, D., & Kachaner, J.
- Venue
- Circulation
- Published
- 2000-08-15
- Volume
- 102
- Issue
- 7
- Pages
- 813-816
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2154748760
- Cited by
- 320
- References
- 11
- FWCI
- 10.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transcatheter Implantation of a Bovine Valve in Pulmonary Position: A Lamb Study. https://app.cochat.ai/papers/10.1161/01.cir.102.7.813
- The paper
- Bonhoeffer, P., Boudjemline, Y., Saliba, Z., Hausse, A. O., Aggoun, Y., Bonnet, D., Sidi, D., & Kachaner, J. (2000). Transcatheter Implantation of a Bovine Valve in Pulmonary Position: A Lamb Study. Circulation. https://doi.org/10.1161/01.cir.102.7.813
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.