The DOI matches its Crossref record.
Prosthesis-Patient Mismatch Affects Survival After Aortic Valve Replacement
Abstract
BACKGROUND: Surgeons traditionally avoid the use of "small" aortic prostheses because of the potential for residual left ventricular outflow tract obstruction and persistent transvalvular gradients. This study examines the ratio between prosthetic valve size and the body surface area (BSA) of patients undergoing aortic valve replacement (AVR). We sought to determine the effect of potential "prosthesis-patient" mismatch on long-term survival. METHODS AND RESULTS: Follow-up was conducted on 2981 patients who underwent AVR with stented bioprostheses between 1976 and 1996. To account for differences between manufacturers' labeled valve sizes, we calculated the ratio between the prosthetic valve effective orifice area (EOA) and the patient's BSA (recorded for 2154 patients). The lowest decile in this cohort had a calculated EOA/BSA of <0.75 cm(2)/m(2) (Small group, n=227) compared with the control group (n=1927), in whom the EOA/BSA ratio was >0.75 cm(2)/m(2). Operative mortality was higher in the Small group (8% versus 5%, P:=0.03). Actuarial survival at 12 years was 50+/-5% in the Small group compared with 49+/-2% in the control group (P:=0.27). However, freedom from valve-related mortality was significantly lower in the Small group (75+/-5% versus 84+/-2%, P:=0.004). Cox regression analysis determined age and NYHA functional class to be the multivariate predictors of overall mortality, whereas advanced age and EOA/BSA <0.75 cm(2)/m(2) were found to be the predictors of valve-related mortality. CONCLUSIONS: Prosthesis-patient mismatch results in significantly higher early and late mortality after bioprosthetic AVR. We recommend careful selection of stented bioprostheses to ensure an adequate ratio of EOA to BSA. An EOA/BSA ratio of >0.75 cm(2)/m(2) may avoid residual left ventricular outflow tract obstruction and persistent transvalvular gradients. Careful prosthesis-patient matching will improve both early and late survival after AVR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Predictors of low cardiac output syndrome after isolated aortic valve surgery
Maganti, M. D., Rao, V., Borger, M. A., Ivanov, J., & David, T. E. (2005) · Circulation · doi:10.1161/circulationaha.104.526087 · Cited by 143
Predictors of low cardiac output syndrome after isolated mitral valve surgery
Maganti, M., Badiwala, M., Sheikh, A., Scully, H., Feindel, C., David, T. E., & Rao, V. (2010) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2009.11.022 · Cited by 115
Self-citationPrice, J., Lapierre, H., Ressler, L., Lam, B.-K., Mesana, T. G., & Ruel, M. (2009) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2009.01.013 · Cited by 7
Metadata
- Authors
- Rao, V., Jamieson, W. R. E., Ivanov, J., Armstrong, S., & David, T. E.
- Venue
- Circulation
- Published
- 2000-11-07
- Volume
- 102
- Issue
- Supplement 3
- Pages
- III-5-III-9
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2117022700
- Cited by
- 312
- References
- 0
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prosthesis-Patient Mismatch Affects Survival After Aortic Valve Replacement. https://app.cochat.ai/papers/10.1161/01.cir.102.suppl_3.iii-5
- The paper
- Rao, V., Jamieson, W. R. E., Ivanov, J., Armstrong, S., & David, T. E. (2000). Prosthesis-Patient Mismatch Affects Survival After Aortic Valve Replacement. Circulation. https://doi.org/10.1161/01.cir.102.suppl_3.iii-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.