The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Paclitaxel Stent Coating Inhibits Neointimal Hyperplasia at 4 Weeks in a Porcine Model of Coronary Restenosis
Abstract
Background —Despite limiting elastic recoil and late vascular remodeling after angioplasty, coronary stents remain vulnerable to restenosis, caused primarily by neointimal hyperplasia. Paclitaxel, a microtubule-stabilizing drug, has been shown to inhibit vascular smooth muscle cell migration and proliferation contributing to neointimal hyperplasia. We tested whether paclitaxel-coated coronary stents are effective at preventing neointimal proliferation in a porcine model of restenosis. Methods and Results —Palmaz-Schatz stents were dip-coated with paclitaxel (0, 0.2, 15, or 187 μg/stent) by immersion in ethanolic paclitaxel and evaporation of the solvent. Stents were deployed with mild oversizing in the left anterior descending coronary artery (LAD) of 41 minipigs. The treatment effect was assessed 4 weeks after stent implantation. The angiographic late loss index (mean luminal diameter) decreased with increasing paclitaxel dose ( P <0.0028 by ANOVA), declining by 84.3% (from 0.352 to 0.055, P <0.05) at the highest level tested (187 μg/stent versus control). Accompanying this change, the neointimal area decreased (by 39.5%, high-dose versus control; P <0.05) with increasing dose ( P <0.040 by ANOVA), whereas the luminal area increased (by 90.4%, high-dose versus control; P <0.05) with escalating dose ( P <0.0004 by ANOVA). Inflammatory cells were seen infrequently, and there were no cases of aneurysm or thrombosis. Conclusions —Paclitaxel-coated coronary stents produced a significant dose-dependent inhibition of neointimal hyperplasia and luminal encroachment in the pig LAD 28 days after implantation; later effects require further study. These results demonstrate the potential therapeutic benefit of paclitaxel-coated coronary stents in the prevention and treatment of human coronary restenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rowinsky, E. K., & Donehower, R. C. (1995) · New England Journal of Medicine · doi:10.1056/nejm199504133321507 · Cited by 1,924
Cited by
Pathological Analysis of Local Delivery of Paclitaxel Via a Polymer-Coated Stent
Farb, A., Heller, P. F., Shroff, S., Cheng, L., Kolodgie, F. D., Carter, A. J., Scott, D. S., Froehlich, J., & Virmani, R. (2001) · Circulation · doi:10.1161/hc3001.092037 · Cited by 423
Self-citationBiodegradable nanoparticles for drug and gene delivery to cells and tissue
Panyam, J., & Labhasetwar, V. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.023 · Cited by 270
Metadata
- Authors
- Heldman, A. W., Cheng, L., Jenkins, G. M., Heller, P. F., Kim, D.-W., Ware, M., Nater, C., Hruban, R. H., Rezai, B., Abella, B. S., Bunge, K. E., Kinsella, J. L., Sollott, S. J., Lakatta, E. G., Brinker, J. A., Hunter, W. L., & Froehlich, J. P.
- Venue
- Circulation
- Published
- 2001-05-08
- Volume
- 103
- Issue
- 18
- Pages
- 2289-2295
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2012417871
- Cited by
- 435
- References
- 1
- FWCI
- 33.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Paclitaxel Stent Coating Inhibits Neointimal Hyperplasia at 4 Weeks in a Porcine Model of Coronary Restenosis. https://app.cochat.ai/papers/10.1161/01.cir.103.18.2289
- The paper
- Heldman, A. W., Cheng, L., Jenkins, G. M., Heller, P. F., Kim, D.-W., Ware, M., Nater, C., Hruban, R. H., Rezai, B., Abella, B. S., Bunge, K. E., Kinsella, J. L., Sollott, S. J., Lakatta, E. G., Brinker, J. A., Hunter, W. L., & Froehlich, J. P. (2001). Paclitaxel Stent Coating Inhibits Neointimal Hyperplasia at 4 Weeks in a Porcine Model of Coronary Restenosis. Circulation. https://doi.org/10.1161/01.cir.103.18.2289
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.