The DOI matches its Crossref record.
Noninvasive Quantification of Coronary Blood Flow Reserve in Humans Using Myocardial Contrast Echocardiography
Abstract
Background—We hypothesized that coronary blood flow (CBF) reserve could be quantified noninvasively in humans using myocardial contrast echocardiography (MCE). Methods and Results—Eleven patients with normal epicardial coronary arteries (group I) and 19 with single-vessel coronary stenosis (group II) underwent quantitative coronary angiography, MCE, and CBF velocity measurements at rest and during intravenous adenosine infusion. In group I patients, MCE-derived myocardial blood flow (MBF) velocity reserve (2.4±0.08) was similar to CBF velocity reserve using a Doppler flow wire (2.4±1.1). Patients with a single risk factor had a significantly higher MBF reserve (3.0±0.89) than those with ≥2 risk factors (1.7±0.22). In group II patients, significant differences were found in MBF velocity reserve in patients with mild (<50%), moderate (50% to 75%), or severe (>75%) stenoses (2.2±0.40, 1.6±0.65, and 0.55±0.19, respectively;P=0.005). A linear relation was found between flow velocity reserve determined using the 2 methods (r=0.76,P<0.001), and a curvilinear relation was noted between the percent coronary stenosis measured using quantitative coronary angiography and velocity reserve using both methods. Conclusions—CBF reserve can be measured in humans using MCE. This method may allow the noninvasive assessment of coronary stenosis severity and the detection of microvascular dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Porter, T. R., Mulvagh, S. L., Abdelmoneim, S. S., Becher, H., Belcik, J. T., Bierig, M., Choy, J., Gaibazzi, N., Gillam, L. D., Janardhanan, R., et al. (2018) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.11.013 · Cited by 432
Detection of Coronary Artery Disease in Asymptomatic Patients With Type 2 Diabetes Mellitus
Scognamiglio, R., Negut, C., Ramondo, A., Tiengo, A., & Avogaro, A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.008 · Cited by 249
Postprandial Myocardial Perfusion in Healthy Subjects and in Type 2 Diabetic Patients
Scognamiglio, R., Negut, C., De Kreutzenberg, S. V., Tiengo, A., & Avogaro, A. (2005) · Circulation · doi:10.1161/circulationaha.104.495127 · Cited by 153
Wang, N., Ko, S.-H., Chai, W., Li, G., Barrett, E. J., Tao, L., Cao, W., & Liu, Z. (2011) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00414.2010 · Cited by 28
Metadata
- Authors
- Wei, K., Ragosta, M., Thorpe, J., Coggins, M., Moos, S., & Kaul, S.
- Venue
- Circulation
- Published
- 2001-05-29
- Volume
- 103
- Issue
- 21
- Pages
- 2560-2565
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2041610099
- Cited by
- 235
- References
- 0
- FWCI
- 14.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Quantification of Coronary Blood Flow Reserve in Humans Using Myocardial Contrast Echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.103.21.2560
- The paper
- Wei, K., Ragosta, M., Thorpe, J., Coggins, M., Moos, S., & Kaul, S. (2001). Noninvasive Quantification of Coronary Blood Flow Reserve in Humans Using Myocardial Contrast Echocardiography. Circulation. https://doi.org/10.1161/01.cir.103.21.2560
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.