Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262Blood Pressure and Hypertension StudiesCardiovascular Health and Disease PreventionNon-Invasive Vital Sign Monitoring

The DOI matches its Crossref record.

Recommendations for Human Blood Pressure Determinations by Sphygmomanometers

Open access

Abstract

IT SHOULD be clearly recognized that arte- rial pressures cannot be measured with precision by means of sphygmomanometers.Direct registration of pressures by cali- brated intra-arterial manometers has shown (1) that even during quiet breathing and slight sinus arrhythmia, systolic and diastolic pres- sures vary from beat to beat by several mm.Hg, and that these differences are greatly in- tensified during states of arrhythmia and deep breathing; (2) that auscultatory systolic read- ings from the brachial artery average 3 or 4 mm.Hg too low and show average scatter of ±8 mm.Hg; and (3) that auscultatory diastolic pressures taken at the point of dulling of the sounds average about 8 mm.Hg too high.The errors of clinical measurement of blood pres- sure can be summarized by saying that in normal persons a mean error of ±8 mm.Hg may be expected in individual readings of sys- tolic and diastolic pressures.Despite this, clin- ical blood pressure determinations have proved very serviceable for practising physicians, clin- icians, insurance carriers, and others concerned with physical examinations, diagnosis, prog- nosis, or therapy.It is important, however, that any basic deficiency of sphygmomanom- etry be not increased by additional errors due to apparatus or technic.The following recommendations have been drawn up with the idea of aiding examiners to avoid pitfalls and, as far as possible, to establish The authors constituted the Committee to Revise "Standardization of High Blood Pressure Readings."This Committee, whose Chairman was Dr. Carl J. Wiggers, functioned under the auspices of the Council for High Blood Pressure Research of the Scientific Council of the American Heart Association.These recommendations are being presented simul_ taneously in Circulation and in the Journal of the American Medical Association.less.A length of bag sufficient to half-encircle

Overview

Integrity signals

Registry

Crossref · 10.1161/01.cir.4.4.503

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

See all 262

Metadata

Authors
BORDLEY, J., CONNOR, C. A. R., HAMILTON, W. F., KERR, W. J., & WIGGERS, C. J.
Venue
Circulation
Published
1951-10
Volume
4
Issue
4
Pages
503-509
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2988207071
Cited by
262
References
0
Citations by year
2025: 1 · 2022: 3 · 2021: 1 · 2020: 3 · 2019: 5 · 2018: 3 · 2014: 1 · 2013: 5 · 2012: 3
FWCI
5.08
Type
journal article
Language
en
Open access
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
blood pressure measurement, measurement error, auscultatory blood pressure, brachial artery
MeSH terms
Blood Pressure, Blood Pressure Determination, Humans, Sphygmomanometers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recommendations for Human Blood Pressure Determinations by Sphygmomanometers. https://app.cochat.ai/papers/10.1161/01.cir.4.4.503
The paper
BORDLEY, J., CONNOR, C. A. R., HAMILTON, W. F., KERR, W. J., & WIGGERS, C. J. (1951). Recommendations for Human Blood Pressure Determinations by Sphygmomanometers. Circulation. https://doi.org/10.1161/01.cir.4.4.503

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.