Cited by 332

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Electrical Stability of Acutely Ischemic Myocardium: Influences of Heart Rate and Vagal Stimulation

Open access
KENT, KENNETH M., SMITH, ELDON R., REDWOOD, DAVID R., EPSTEIN, STEPHEN E.·1973·Circulation

Abstract

Previous investigations have shown that a slower heart rate (HR) and myocardial ischemia independently diminish the electrical stability of the heart. It therefore was suggested that increasing heart rate during myocardial infarction might diminish the incidence of serious ventricular arrhythmias. However, since increased HR during experimental acute myocardial ischemia augments the degree of ischemia, an evaluation of the presumed "protective" effects of increased HR on the electrical stability of acutely ischemic myocardium was undertaken. The differences in refractory periods (RP) of eight contiguous areas of the left ventricle were determined as a function of HR. In nonischemic myocardium, the disparity of RP was less at an HR of 180 than 60. However, in ischemic myocardium the disparity increased in three of six animals as the HR was increased from 60 to 90, in seven of 10 animals as HR was increased from 60 to 120, and in all animals when the HR was increased from 60 to 180. The increased disparity of RP is believed to favor development of reentrant arrhythmia. The vulnerability of the heart to develop ventricular fibrillation was assessed by determining ventricular fibrillation threshold (VFT). During ischemia, VFT was not only an inverse function of HR but also was found to be independently influenced by electrical stimulation of the cervical vagus nerves. In the absence of vagal stimulation VFT was lowered in only one of four dogs as HR was increased from 50 to 90, but decreased 30% ( P < 0.01) as HR reached 120 and 74% at 180 beats/min. When vagal stimulation was used to control HR VFT was lowered 37% as HR was increased from 50 to 60 to 90 ( P < 0.05). We conclude that increasing HR within a physiologic range by diminishing vagal tone during myocardial ischemia decreases electrical stability of the ventricle by (1) increasing ischemia consequent to the rate-induced increase in myocardial oxygen requirements, and (2) a direct electrophysiologic action of the vagus on the ventricular myocardium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.47.2.291

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 332

Metadata

Authors
KENT, K. M., SMITH, E. R., REDWOOD, D. R., & EPSTEIN, S. E.
Venue
Circulation
Published
1973-02
Volume
47
Issue
2
Pages
291-298
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1997535715
Cited by
332
References
12
FWCI
17.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrical Stability of Acutely Ischemic Myocardium: Influences of Heart Rate and Vagal Stimulation. https://app.cochat.ai/papers/10.1161/01.cir.47.2.291
The paper
KENT, K. M., SMITH, E. R., REDWOOD, D. R., & EPSTEIN, S. E. (1973). Electrical Stability of Acutely Ischemic Myocardium: Influences of Heart Rate and Vagal Stimulation. Circulation. https://doi.org/10.1161/01.cir.47.2.291

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.