The DOI matches its Crossref record.
Measurement of midwall myocardial dynamics in intact man by radiography of surgically implanted markers.
Open accessAbstract
Tiny radiopaque helices (0.85 times 1.5 mm) of pure tantalum wire were implanted by means of a simple insertor instrument into the left ventricular myocardium in 24 patients at the time of cardiac surgery. The markers were positioned in such a way as to outline the profile of the left ventricle when viewed in a 30 degree right anterior oblique projection. Biplane studies showed that all markers could be placed very nearly in a plane using the surface anatomy of the heart as a guide to implantation. Implantation of markers required approximately two minutes. No intraoperative or postoperative complications ascribable to the markers have occurred. They remain firmly in place and allow acquisition of a noninvasive ventriculogram at any time after surgery. The dynamic geometry of the left ventricle was determined by analysis of cineradiograms of these markers. Utilization of a single-plane (right anterior oblique) cineradiogram to obtain measurements of major transverse ventricular diameters, mean circumferential shortening, and circumferential shortening velocity results in underestimation of lenghts by 1.4%, overestimation of shortening by 1.2% of end-diastolic length, and overestimation of velocity by 0.05 circ/sec, when compared with values obtained simultaneously from biplane cineradiograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stuber, M., Scheidegger, M. B., Fischer, S. E., Nagel, E., Steinemann, F., Hess, O. M., & Boesiger, P. (1999) · Circulation · doi:10.1161/01.cir.100.4.361 · Cited by 368
Fibrous scaffolds for building hearts and heart parts
Capulli, A. K., MacQueen, L. A., Sheehy, S. P., & Parker, K. K. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.020 · Cited by 130
Metadata
- Authors
- Ingels, N. B., Daughters, G. T., Stinson, E. B., & Alderman, E. L.
- Venue
- Circulation
- Published
- 1975-11
- Volume
- 52
- Issue
- 5
- Pages
- 859-867
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2083460269
- Cited by
- 248
- References
- 0
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of midwall myocardial dynamics in intact man by radiography of surgically implanted markers. https://app.cochat.ai/papers/10.1161/01.cir.52.5.859
- The paper
- Ingels, N. B., Daughters, G. T., Stinson, E. B., & Alderman, E. L. (1975). Measurement of midwall myocardial dynamics in intact man by radiography of surgically implanted markers. Circulation. https://doi.org/10.1161/01.cir.52.5.859
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.