The DOI matches its Crossref record.
Cardiac imaging using a phased array ultrasound system. I. System design.
Open accessAbstract
A new two-dimensional, real-time, high resolution ultrasound imaging system is described. This system uses a linear array of ultrasound transducers to generate tomographic images of the heart in a circular sector format. Phased array techniques allow rapid steering of the ultrasound beam so that images are produced at the rate of 20 per second, or more, while maintaining a resolution of 2-4 mm throughout the field of view.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering
Smith, S. W., Pavy, H. G., & von Ramm, O. T. (1991) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.68466 · Cited by 504
Self-citationA novel method for angle independent ultrasonic imaging of blood flow and tissue motion
Bohs, L. N., & Trahey, G. E. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.133210 · Cited by 438
Dielectric and piezoelectric properties of PVDF/PZT composites: A review
Jain, A., K. J., P., Sharma, A. K., Jain, A., & P.N, R. (2015) · Polymer Engineering & Science · doi:10.1002/pen.24088 · Cited by 438
Wyatt, H. L., Heng, M. K., Meerbaum, S., Hestenes, J. D., Cobo, J. M., Davidson, R. M., & Corday, E. (1979) · Circulation · doi:10.1161/01.cir.60.5.1104 · Cited by 368
Beam Steering with Linear Arrays
Von Ramm, O. T., & Smith, S. W. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325149 · Cited by 262
Self-citationStewart, J. A., Silimperi, D., Harris, P., Wise, N. K., Fraker, T. D., & Kisslo, J. A. (1980) · Circulation · doi:10.1161/01.cir.61.2.374 · Cited by 261
Schluter, M., Langenstein, B. A., Polster, J., Kremer, P., Souquet, J., Engel, S., & Hanrath, P. (1982) · Heart · doi:10.1136/hrt.48.1.67 · Cited by 168
Metadata
- Authors
- vonRamm, O. T., & Thurstone, F. L.
- Venue
- Circulation
- Published
- 1976-02
- Volume
- 53
- Issue
- 2
- Pages
- 258-262
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2042500074
- Cited by
- 186
- References
- 0
- FWCI
- 28.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.