Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 340

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Influence of acute changes in preload, afterload, contractile state and heart rate on ejection and isovolumic indices of myocardial contractility in man.

Quinones, M A, Gaasch, W H, Alexander, J K·1976·Circulation

Abstract

To determine the sensitivity of several isovolumic and ejection phase indices of myocardial contractility to loading, inotropic stimulation and heart rate in man, 14 patients (pts) were studied during cardiac catheterization with simultaneous recordings of left ventricular (LV) pressures and ultrasound dimensions. Measurements were made of instantaneous and mean circumferential fiber shortening velocity (VCF), maximal (max) rate of LV pressure rise (dP/dt), dPHdt divided by end-diastolic circumference [(dP/dt)/C], (DP/dt)/C divided by aortic valve opening pressure [(dP/dt/CP], PEAK CONTRACTILe element velocity (VCE) using total LV pressure, VCE extrapolated to zero total pressure (Vmax), VCE at a developed pressure of 10 mm Hg (VCEDP10) and dP/dt at a common isovolumic developed pressure of 40 mm Hg [(dP/dt)/DP40]. Resulta are expressed in per cent change of the mean for the group. Acute preload increase (8.6% increase in end-diastolic circumference) with volume expansion at constant heart rate in 7 pts produced insignificant changes in VSF, an 8.3% increase in max dP/dt, no change in (dP/dt)/C, a variable response in (dP/dt)/CP, 18% reduction in peak VCE, 16% reduction in Vmax, 14% increase in VCEDP10, and a 10% increase in (dP/dt)/DP40. An acute increase in afterload produced by angiotensin in 8 pts (44% increase in peak stress) led to a 38% decrease in VCF, a 2.5% increase in max dP/dt, no significant change in (dP/dt)/C, a 26% reduction in (dP/dt)/CP, variable responses in peak VCE and Vmax, an 11% increase in VCEDP10 and minor changes in (dP/dt)/DP40. All of the contractility indices were augmented significantly by isoproterenol and atrial pacing. In a given patient, max, dP/dt appears to be useful in the assessment of acute changes in inotropic state since the magnitude of its response to abrupt changes in preload is small and to afterload insignificant. Normalizing max dP/dt for end-diastolic circumference assures better stability during loading with good sensitivity to inotropic stimulation. VCF may be used whenever changes in afterload are minimal. The isovolumic measurements of VCE (regardless of whether total or developed pressure is used) lack sufficient stability during acute changes in loading conditions to warrant their use in the quantitative assessment of acute changes in inotropic state.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.53.2.293

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 340

Metadata

Authors
Quinones, M. A., Gaasch, W. H., & Alexander, J. K.
Venue
Circulation
Published
1976-02
Volume
53
Issue
2
Pages
293-302
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1985396584
Cited by
340
References
11
FWCI
8.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of acute changes in preload, afterload, contractile state and heart rate on ejection and isovolumic indices of myocardial contractility in man. https://app.cochat.ai/papers/10.1161/01.cir.53.2.293
The paper
Quinones, M. A., Gaasch, W. H., & Alexander, J. K. (1976). Influence of acute changes in preload, afterload, contractile state and heart rate on ejection and isovolumic indices of myocardial contractility in man. Circulation. https://doi.org/10.1161/01.cir.53.2.293

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.