CoChat

Nitroglycerin-induced severe hypotension and bradycardia in patients with acute myocardial infarction.

Open access
Come, P C, Pitt, B · 1976 · Circulation
Cited by 150

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Seven episodes of simultaneous severe systemic arterial hypotension and absolute or relative bradycardia were observed in five patients receiving either sublingual nitroglycerin (two patients) or intravenous nitroglycerin (three patients) within the first 24 hours of onset of symptoms of acute myocardial infarction. Left ventricular filling pressure, measured as pulmonary artery diastolic pressure, decreased simultaneously in all four patients in whom pulmonary artery pressures were monitored. No initial increase in heart rate was observed in any of the five patients prior to the development of bradycardia. Possible mechanisms producing simultaneous bradycardia and hypotension during nitroglycerin administration are considered. The patient studies emphasize the importance of careful hemodynamic monitoring during administration of sublingual or intravenous nitroglycerin to patients with acute myocardial infarction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.54.4.624

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Come, P. C., & Pitt, B.
Venue
Circulation
Published
1976-10
Volume
54
Issue
4
Pages
624-628
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2082221420
Cited by
150
References
1
FWCI
5.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.