Antiarrhythmic drug effect mimicked by spontaneous variability of ventricular ectopy.
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Twenty patients with frequent ventricular ectopic beats had a 5 1/2 hour ECG rhythm strip recorded. Individual patients showed a marked spontaneous variability from one half-hour to the next in the total number of ectopic beats (-99% to +1100%) and the occurrence of pairs or salvos. Although no patient received antiarrhythmic drugs, some patients showed a spontaneous change in arrhythmia which mimicked either drug suppression or drug-induced worsening of arrhythmias. If an antiarrhythmic drug had been given to these patients after the first half-hour, 65% would have been termed "drug responders," using the criteria of 50% reduction in ectopic beats and elimination of pairs or salvos during any half-hour period in the subsequent three hours. Spontaneous variability in ventricular ectopic beats causes serious problems when using ECG monitoring to evaluate antiarrhythmic drug response in individual patients. The arrhythmias averaged for the entire group remained stable during the recording period. Evaluating antiarrhythmic drugs by examining group response rather than individual patient response minimizes the effect of spontaneous variability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BIGGER, J. T., SCHMIDT, D. H., & KUTT, H. (1968) · Circulation · doi:10.1161/01.cir.38.2.363 · Cited by 166
Antiarrhythmic Drug Therapy for Sporadic Ventricular Ectopic Arrhythmias
Jelinek, M. V., Lohrbauer, L. A., & Lown, B. (1974) · Circulation · doi:10.1161/01.cir.49.4.659 · Cited by 86
Chopra, M., Thadani, U., Portal, R. W., & Aber, C. P. (1971) · BMJ · doi:10.1136/bmj.3.5776.668 · Cited by 76
Acute oral testing for determining antiarrhythmic drug efficacy
Gaughan, C. E., Lown, B., Lanigan, J., Voukydis, P. C., & Besser, H. W. (1976) · The American Journal of Cardiology · doi:10.1016/0002-9149(76)90342-8 · Cited by 70
Effect of a Digitalis Drug on Ventricular Premature Beats
Lown, B., Graboys, T. B., Podrid, P. J., Cohen, B. H., Stockman, M. B., & Gauchan, C. E. (1977) · New England Journal of Medicine · doi:10.1056/nejm197702102960603 · Cited by 63
Lown, B. (1975) · JAMA · doi:10.1001/jama.1975.03250010021017 · Cited by 39
Cited by
Aggravation and provocation of ventricular arrhythmias by antiarrhythmic drugs.
Velebit, V, Podrid, P., Lown, B., Cohen, B. H., & Graboys, T. B. (1982) · Circulation · doi:10.1161/01.cir.65.5.886 · Cited by 632
Maron, B. J., Savage, D. D., Wolfson, J. K., & Epstein, S. E. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90604-4 · Cited by 495
Flecainide: Its proarrhythmic effect and expected changes on the surface electrocardiogram
Morganroth, J., & Horowitz, L. N. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90509-5 · Cited by 280
Oral Flecainide Acetate for the Treatment of Ventricular Arrhythmias
Anderson, J. L., Stewart, J. R., Perry, B. A., Van Hamersveld, D. D., Johnson, T. A., Conard, G. J., Chang, S. F., Kvam, D. C., & Pitt, B. (1981) · New England Journal of Medicine · doi:10.1056/nejm198108273050901 · Cited by 222
Chakko, C. S., & Gheorghiade, M. (1985) · American Heart Journal · doi:10.1016/0002-8703(85)90554-x · Cited by 190
Metadata
- Authors
- Winkle, R. A.
- Venue
- Circulation
- Published
- 1978-06
- Volume
- 57
- Issue
- 6
- Pages
- 1116-1121
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2038203329
- Cited by
- 256
- References
- 6
- FWCI
- 18.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.