Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Diastolic left ventricular pressure-volume and stress-strain relations in patients with valvular aortic stenosis and left ventricular hypertrophy.

Peterson, K L, Tsuji, J, Johnson, A, DiDonna, J, LeWinter, M · 1978 · Circulation

Abstract

Left ventricular (LV) chamber and myocardial stiffness were determined in 17 patients, four subjects with normal LV function and 13 subjects with valvular aortic stenosis and concentric myocardial hypertrophy, using simultaneous catheter micromanometry and LV cineangiography. Pressure (P), volume (V), and wall thickness (h) were measured. Variability in both chamber and myocardial stiffness parameters was found with five of the aortic stenosis patients (Group 1, left ventricular end-diastolic pressure = 15 +/- 2 (SEM) mm Hg) exhibiting normal values for end-diastolic dP/dV and dP/dV/V, for chamber stiffness constants (a,a') derived from P-V and normalized P-V relations, respectively, for end-diastolic myocardial elastic stiffness (ES or EE, where S = spherical model and E = ellipsoidal model) at the midwall of the minor axis circumference, and for the myocardial stiffness constants (KS or KE) of the circumferential stress-strain relation. Eight other patients with aortic stenosis (Group II, left ventricular end-diastolic pressure = 20 +/- 3 (SEM) mm Hg) exhibited significant increases in end-diastolic dP/dV,dP/dV/V,ES and EE and a tendency for increase in the chamber stiffness constants (a,a') and myocardial stiffness constants (KS, KE). These observations suggest that concentric increase in muscle mass (increase in wall thickness/minor axis radius ratio and wall volume/chamber volume ratio) is an important determinant of elevated mid- and late diastolic pressures in patients with valvular aortic stenosis, while concurrently mitigating increases in both systolic and diastolic wall stress. In some patients with aortic stenosis, however, diastolic filling pressures are elevated more severely, not only as a result of concentric hypertrophy, but also in response to augmented muscle stiffness. Reversibility of increased ventricular diastolic stiffness and elevated filling pressures was documented as concentric hypertrophy regressed post-aortic valve replacement in one patient, suggesting that fibrosis is not invariably the cause of enhanced myocardial stiffness in this secondary and compensatory form of hypertrophy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.58.1.77

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 161

Metadata

Authors
Peterson, K. L., Tsuji, J., Johnson, A., DiDonna, J., & LeWinter, M.
Venue
Circulation
Published
1978-07
Volume
58
Issue
1
Pages
77-89
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2004415881
Cited by
161
References
1
FWCI
7.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diastolic left ventricular pressure-volume and stress-strain relations in patients with valvular aortic stenosis and left ventricular hypertrophy. https://app.cochat.ai/papers/10.1161/01.cir.58.1.77
The paper
Peterson, K. L., Tsuji, J., Johnson, A., DiDonna, J., & LeWinter, M. (1978). Diastolic left ventricular pressure-volume and stress-strain relations in patients with valvular aortic stenosis and left ventricular hypertrophy. Circulation. https://doi.org/10.1161/01.cir.58.1.77

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.