Limitations of routine long-term electrocardiographic monitoring to assess ventricular ectopic frequency.
Abstract
Variations in the frequency of ventricular premature depolarizations (VPDs) were evaluated with three consecutive 24-hour long-term electrocardiography monitor recordings from 15 clinically stable patients with various cardiac disorders. Mean hourly VPD frequencies ranged from 37--1,801 per hour. Data were subjected to 4 and 5 factor nested analyses of variance. The extent of spontaneous variation in arrhythmia frequency that occurred in individual patients from day to day was 23%, between 8-hour periods within days was 29%, and from hour to hour was 48%. In addition, the variability between repeated three-day monitoring periods over time was quantified in five patients and found to be 37%. This analysis determined that to distinguish a reduction in VPD frequency attributable to therapeutic intervention rather than biologic or spontaneous variation alone required a greater than 83% reduction in VPD frequency if only two-24-hour monitoring periods were compared, and greater than 65% reduction if two 72-hour periods were compared. The limitations of routine 24-hour electrocardiographic monitoring must be considered in diagnostic and therapeutic decision-making.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ACC/AHA guidelines for ambulatory electrocardiography
Crawford, M. H., Bernstein, S. J., Deedwania, P. C., DiMarco, J. P., Ferrick, K. J., Garson, A., Green, L. A., Greene, H. L., Silka, M. J., Stone, P. H., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00354-x · Cited by 309
Use of ambulatory electrocardiographic (Holter) monitoring
DiMarco, J. P., & Philbrick, J. T. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-1-53 · Cited by 177
The Evolving Role of Ambulatory Arrhythmia Monitoring in General Clinical Practice
Zimetbaum, P. J., & Josephson, M. E. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-10-199905180-00020 · Cited by 139
Self-citationZeldis, S. M., Levine, B. J., Michelscn, E. L., & Morganroth, J. (1980) · Chest · doi:10.1378/chest.78.3.456 · Cited by 124
Self-citationTwenty-Four-Hour Ambulatory Electrocardiography in Normal Cats
Ware, W. A. (1999) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.1999.tb02174.x · Cited by 34
Metadata
- Authors
- Morganroth, J., Michelson, E. L., Horowitz, L. N., Josephson, M. E., Pearlman, A. S., & Dunkman, W. B.
- Venue
- Circulation
- Published
- 1978-09
- Volume
- 58
- Issue
- 3
- Pages
- 408-414
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2015169899
- Cited by
- 564
- References
- 0
- FWCI
- 30.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limitations of routine long-term electrocardiographic monitoring to assess ventricular ectopic frequency. https://app.cochat.ai/papers/10.1161/01.cir.58.3.408
- The paper
- Morganroth, J., Michelson, E. L., Horowitz, L. N., Josephson, M. E., Pearlman, A. S., & Dunkman, W. B. (1978). Limitations of routine long-term electrocardiographic monitoring to assess ventricular ectopic frequency. Circulation. https://doi.org/10.1161/01.cir.58.3.408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.