Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 735

The DOI matches its Crossref record.

A new, simplified and accurate method for determining ejection fraction with two-dimensional echocardiography.

Open access
Quinones, M A, Waggoner, A D, Reduto, L A, Nelson, J G, Young, J B, Winters, W L, Ribeiro, L G, Miller, R R·1981·Circulation

Abstract

A new method to determine left ventricular (LV) ejection fraction (EF) with wide-angle, two-dimensional echocardiography (2-D echo) has been developed using the parasternal long-axis, apical four-chamber and apical long-axis views. End-diastolic and end-systolic measurements of LV short axes at the base and mid-LV cavity in the parasternal long-axis view and at the upper, middle and lower thirds of the cavity in the apical views are made, from which an averaged minor axis at end-diastolic and at end-systole is calculated. Fractional shortening of the LV long axis (delta L) is estimated from apical contraction. Satisfactory 2-D echoes were obtained in 55 of 58 nonselected patients (all three views in 32 patients, two views in 22 and one view in one); 42 of 55 patients had coronary artery disease. EF by 2-D echo was compared with EF by gated cardiac blood pool imaging in all patients (r = 0.927, SEE = 6.7%) and to EF by single-plane cineangiography (angio) in 35 of 55 patients (r = 0.913, SEE = 7.4%). LV dyssynergy was frequently present and involved the apex in 29 of 55 patients. Using angio as the standard for evaluating wall motion at the apex, 2-D echo was 100% sensitive and specific in detecting abnormal apical wall motion. We conclude that EF can be determined accurately with 2-D echo in a large group of patients with and without dyssynergy by a simple method that eliminates the need for planimetry or computer assistance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.64.4.744

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 735

Metadata

Authors
Quinones, M. A., Waggoner, A. D., Reduto, L. A., Nelson, J. G., Young, J. B., Winters, W. L., Ribeiro, L. G., & Miller, R. R.
Venue
Circulation
Published
1981-10
Volume
64
Issue
4
Pages
744-753
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2006565016
Cited by
735
References
0
FWCI
8.61
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A new, simplified and accurate method for determining ejection fraction with two-dimensional echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.64.4.744
The paper
Quinones, M. A., Waggoner, A. D., Reduto, L. A., Nelson, J. G., Young, J. B., Winters, W. L., Ribeiro, L. G., & Miller, R. R. (1981). A new, simplified and accurate method for determining ejection fraction with two-dimensional echocardiography. Circulation. https://doi.org/10.1161/01.cir.64.4.744

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.