The DOI matches its Crossref record.
Ultrasonic duplex scanning for disease of the carotid artery.
Abstract
The duplex ultrasonic scanner combines real-time B-mode imaging with a single-gate, variable-range pulsed Doppler. The detection and categorization of the severity of carotid artery atherosclerosis is achieved by performing spectral analysis of the pulsed Doppler velocity signal obtained from vessels of interest. Using this technique, 750 patients with suspected extracranial carotid artery disease were evaluated between January 1978 and January 1980. One hundred thirty-five of these 750 patients (18%) underwent cerebral arteriography performed with biplanar views of the carotid bifurcation. The degree of stenosis was measured independently in these patients and was available for comparison with the results of duplex scanning and spectral analysis. Duplex scanning correctly detected the presence of disease in 252 of 259 carotid arteries studied (97%). The extent of involvement varied from plaques that produced less than 10% diameter reduction to those that resulted in a total occlusion. The technique was less accurate with lesions that produced less than 10% diameter reduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Association Between Arterial Stiffness and Atherosclerosis: The Rotterdam Study
van Popele, N. M., Grobbee, D. E., Bots, M. L., Asmar, R., Topouchian, J., Reneman, R. S., Hoeks, A. P. G., van der Kuip, D. A. M., Hofman, A., & Witteman, J. C. M. (2001) · Stroke · doi:10.1161/01.str.32.2.454 · Cited by 1,142
Carotid plaque histology using real-time ultrasonography
Reilly, L. M., Lusby, R. J., Hughes, L., Ferrell, L. D., Stoney, R. J., & Ehrenfeld, W. K. (1983) · The American Journal of Surgery · doi:10.1016/0002-9610(83)90370-7 · Cited by 345
Duplex ultrasound measurement of postprandial intestinal blood flow: Effect of meal composition
Moneta, G. L., Taylor, D. C., Helton, W. S., Mulholland, M. W., & Strandness, D. E. (1988) · Gastroenterology · doi:10.1016/0016-5085(88)90364-2 · Cited by 277
Self-citation
Metadata
- Authors
- Fell, G., Phillips, D. J., Chikos, P. M., Harley, J. D., Thiele, B. L., & Strandness, D. E.
- Venue
- Circulation
- Published
- 1981-12
- Volume
- 64
- Issue
- 6
- Pages
- 1191-1195
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2017337288
- Cited by
- 220
- References
- 0
- FWCI
- 22.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasonic duplex scanning for disease of the carotid artery. https://app.cochat.ai/papers/10.1161/01.cir.64.6.1191
- The paper
- Fell, G., Phillips, D. J., Chikos, P. M., Harley, J. D., Thiele, B. L., & Strandness, D. E. (1981). Ultrasonic duplex scanning for disease of the carotid artery. Circulation. https://doi.org/10.1161/01.cir.64.6.1191
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.