The DOI matches its Crossref record.
Effect of perfusion pressure distal to a coronary stenosis on transmural myocardial blood flow.
Open accessAbstract
We tested the hypothesis that reductions of perfusion pressure distal to a flow-limiting coronary artery stenosis can directly impair perfusion of the subendocardial myocardium. Dogs were instrumented with an electromagnetic flowmeter probe and a variable occluder on the proximal left circumflex coronary artery. Coronary perfusion pressure was measured with a catheter distal to the occluder. Coronary autoregulation was abolished by intraarterial infusion of adenosine to produce maximal coronary vasodilation. The transmural distribution of myocardial blood flow was measured with radioactive microspheres during unimpeded arterial inflow, when the occluder was progressively narrowed to reduce distal coronary pressure to approximately 70%, 50% and 35% of the control coronary perfusion pressure, and during total coronary occlusion. Heart rate, left ventricular diastolic pressure and the fraction of coronary artery flow during systole remained constant throughout the study. Progressive reductions of coronary perfusion pressure were accompanied by direct reductions of the subendocardial/subepicardial blood flow ratio (r = 0.83). Examination of the relationship between myocardial blood flow and coronary perfusion pressure showed that blood flow decreased linearly with perfusion pressure, with flow ceasing at a positive pressure (zero-flow pressure). Blood flow data from four transmural myocardial layers from epicardium to endocardium showed that this zero-flow pressure increased progressively from 10 +/- 2.1 mm Hg in the subepicardium to 18 +/- 2.3 mm Hg in the subendocardium (p less than -.01). Consequently, as coronary pressure was reduced, the zero-flow pressure represented a progressively greater fraction of coronary pressure in the subendocardium than in the subepicardium. This effect appeared to account for the progressive redistribution of blood flow away from the subendocardium that occurred as coronary pressure was decreased. Myocardial vascular resistance did not change as a result of changes in coronary perfusion pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pellikka, P. A., Arruda-Olson, A., Chaudhry, F. A., Chen, M. H., Marshall, J. E., Porter, T. R., & Sawada, S. G. (2020) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.07.001 · Cited by 583
Al-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000) · Circulation · doi:10.1161/01.cir.101.12.1379 · Cited by 578
Coronary flow reserve as a physiologic measure of stenosis severity
Gould, K. L., Kirkeeide, R. L., & Buchi, M. (1990) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80078-6 · Cited by 548
Rajappan, K., Rimoldi, O. E., Dutka, D. P., Ariff, B., Pennell, D. J., Sheridan, D. J., & Camici, P. G. (2002) · Circulation · doi:10.1161/hc0402.102931 · Cited by 358
Rajappan, K., Rimoldi, O. E., Camici, P. G., Bellenger, N. G., Pennell, D. J., & Sheridan, D. J. (2003) · Circulation · doi:10.1161/01.cir.0000074211.28917.31 · Cited by 215
Metadata
- Authors
- Bache, R. J., & Schwartz, J. S.
- Venue
- Circulation
- Published
- 1982-05
- Volume
- 65
- Issue
- 5
- Pages
- 928-935
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2115207732
- Cited by
- 162
- References
- 0
- FWCI
- 14.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of perfusion pressure distal to a coronary stenosis on transmural myocardial blood flow. https://app.cochat.ai/papers/10.1161/01.cir.65.5.928
- The paper
- Bache, R. J., & Schwartz, J. S. (1982). Effect of perfusion pressure distal to a coronary stenosis on transmural myocardial blood flow. Circulation. https://doi.org/10.1161/01.cir.65.5.928
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.